Differential
Input
Termination
Each
port
on
the
card
has
optional
termination
of
RS
‐
422/485
differential
inputs.
When
a
resistor
pack
is
installed
in
the
socket
labeled
‘TERM’,
all
differential
inputs
for
that
port
are
terminated
with
120
ohms.
By
default
the
termination
resistor
pack
is
installed
for
all
ports.
The
presence
of
the
termination
resistor
pack
does
not
affect
single
ended
(RS
‐
232/V.28)
inputs.
Termination
is
used
to
increase
signal
reliability
at
high
speeds
(generally
1Mbps
or
more).
At
high
speeds,
receivers
at
each
end
of
a
cable
should
be
terminated.
For
a
multi
‐
drop
setups
(more
than
2
devices
on
a
cable),
do
not
terminate
receivers
connected
to
the
middle
of
the
cable.
At
slower
speeds,
the
termination
can
usually
remain
without
problem.
Removing
termination
at
slower
speeds
may
allow
the
use
of
longer
cables.
To
remove
a
termination
resistor
pack,
identify
the
socket
labeled
‘TERM’.
Then
remove
the
yellow
resistor
pack
from
the
black
socket
using
a
flat
head
screw
driver
or
equivalent
tool.
Termination
can
be
reinstalled
by
pressing
the
resistor
pack
back
into
the
socket.
Take
care
that
the
pins
on
the
resistor
pack
are
not
bent
and
are
firmly
seated
into
the
socket.
Figure
3 Termination
Sockets