Section 2: System Operation 

 

The RX10 can be used to remotely switch up to 10 different circuits. This can be achieved by independently 

programming each zone with simple Close and Open latching commands. Zones can also be programmed 
for momentary operation, and if required, a single command can be used to toggle the state of each zone. A 

Reset function returns all zones to their initial state. This can be activated either over the air (by  

transmitting the programmed command) or by operation of the front panel key switch. A Common relay 
will latch when any zone is active. This can also be programmed to operate an internal sounder. The relay 

can be used for connection to an external sounder or light providing a remote indication of system activity. 

 
Both the configuration and uses of the RX10 are limited only by the user’s imagination, so here we will 

provide just a few examples of how its functionality can be utilized. 

 

Example 1

 

You want to use Zone 1 to switch on a light when you transmit a command. You then want to 

switch the light off by transmitting a different command.  To do this, connect your switch wires to the N/O 
and Common terminals of Zone 1.  In the RX10 Pro Configuration utility, click on the Chan 1 tab. In the 

“Close” section, enable the tick box then enter the chosen RIC (or range of RICs) for switching the light on. 

In the “Open” section, enable the tick box and enter your chosen RIC (or range of RICs) for switching the 
light off (for a fuller explanation of programming the RX10, see Section 3). 

 

When you transmit the “Close” RIC stored in Chan 1, the relay contacts will close, completing the circuit. 
The Zone 1 LED on the main board and on the front panel will light. The Common relay will also operate 

and the Common LED on the main board and front panel will also light. When you transmit the “Open” 
RIC stored for Zone 1, the relay contacts will open, breaking the circuit. The Zone 1 LEDs will extinguish, 

the Common relay contacts will open and the Common LEDs will extinguish.

 

 

Example 2

:

  

You want to use a single command on Zone 3 to switch a motor both On and Off for a  

10-second period. To do this, connect your switch wires as in Example 1 if you require the motor to be in 

the Off state when the RX10 is initially powered up or reset. If you require it to be ON in this state, 
connect the wires to the N/C and Common terminals. In the RX10 Pro Configuration utility, click on the 

Zone 3 tab, then set the “Tmax” value to 10 (seconds). Now enter your command RIC (or range of RICs) in 

the “Toggle” section and enable the tick box.  When you transmit the stored “Toggle” RIC, the motor will 
run for 10 seconds, then stop. Transmit again to run the motor for a further 10 seconds. If you transmit the 

RIC whilst the motor is running (i.e. during the set time period of 10 seconds), it will stop. Transmit again 
to run the motor for a further 10-second period. 

 

Example 3

:

 

You have a “supervised” system where the transmitter sends out test calls at timed intervals. 

If the receiver fails to receive any test calls, you want to signal this by opening a pair of contacts.  To do 

this, in the RX10 Pro Configuration utility choose a zone (Chan) and set the Tmax value to a period greater 

than your transmitter’s test call period. Enable the “Close” function and enter your test call RIC. Wire the 
signal cables to the N/O and Common terminals of the selected Zone. 

 
 

 
 
 
 
 

 

Содержание RX10

Страница 1: ... Zone Receiver Decoder Operating Manual Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail support microframecorp com ...

Страница 2: ...ication to the product without first contacting Microframe Corporation Warning All power transformers line cords and electrical equipment should be kept out of the reach of children and away from water If you are installing cable in an air plenum area such as a drop ceiling used for air return you must use plenum rated cable The cable supplied from Microframe is rated CL2 and is approved for insta...

Страница 3: ...ons available on screw terminal blocks located on the main circuit board see diagram 1 The maximum contact rating of each relay is 0 5A 125V AC 1A 60V DC A Common relay will latch when any of the 10 zone relays is triggered This can also be programmed to activate an internal sounder The unit can be reset by using either the key operated switch on the front of the RX10 or by transmitting a programm...

Страница 4: ...e unit on the wall remove the two screws from the front of the case and separate the cover from the base plate taking care not to stress the ribbon cable which connects the front panel indicators to the main circuit board as well as the cables which connect the Reset switch to the main board For ease of installation the ribbon cable can be removed from the main board by lifting the collar either s...

Страница 5: ...d in close proximity to a Foil back plasterboard b Metal mesh or wire reinforced glass c Metal sheeting large mirrors or suspended ceilings d Lift shafts All of the above can reflect radio waves and thereby reduce the capability of the receiver to perform its desired functions 6 The circuit boards within this equipment may be harmed by Electrostatic Discharge ESD Installers should ensure that both...

Страница 6: ...ribbon cable ensure that the connector collar is raised and check that the cable is square to the connector Ensure that the cable runs straight in the direction shown Gently insert the cable tail as far as it will go then push down equally on both sides of the connector collar ...

Страница 7: ...in Chan 1 the relay contacts will close completing the circuit The Zone 1 LED on the main board and on the front panel will light The Common relay will also operate and the Common LED on the main board and front panel will also light When you transmit the Open RIC stored for Zone 1 the relay contacts will open breaking the circuit The Zone 1 LEDs will extinguish the Common relay contacts will open...

Страница 8: ...hether to select the Close and Open functions To avoid confusion the Close function for each relay can be best described as when the relay is energized and the Open function as when the relay is de energized For example if the N C terminal configuration is used when the Close command RIC is transmitted the relay will energize and the contacts will go open After this if the Open command RIC is sent...

Страница 9: ...s XP Prior to programming the RX10 enter the Comm port and the comms baud rate which you are using on your PC to program the RX10 Fit a standard 9 pin null modem serial cable between your PC Com port and the RX10 serial port To check the set baud rate of the RX10 select GET to read the stored data The unit is now ready to accept programming data ...

Страница 10: ...ecoder b General Set Up File Name and Build are read only fields Data will appear in the boxes after a file is saved or opened The baud rate and data polarity must be chosen to match the settings of the transmitter used with the system ...

Страница 11: ...ration required maximum is 255 seconds The sounder can be programmed to activate when the common relay is triggered by checking the Link Common relay Sounder box iii Repeated Toggle Command Filter Where the transmitter is programmed to send repeat calls for added integrity it may be required to filter out these repeats if the Toggle function is being used otherwise the relay will change state ever...

Страница 12: ... received For latched continuous activation the TMax box must be set to 0 For Close and Open functions repeat receipts of the same activation RICs will be ignored unless a timed activation state has been set as detailed below Where a timed state is required this can be set between 1 and 255 seconds after which the relay will revert to its previous state As explained above in Example 3 if the same ...

Страница 13: ... RIC 1 and RIC 2 Where individual RICs are selected a specific beep type A B C D must also be entered When the chosen RIC beep type message is transmitted the message will be passed to the serial port ii Serial Output Logger A range of RICs can be entered together with either a specific beep type or All where any beep type is valid If the serial port is being used to pass data to a Scope transmitt...

Страница 14: ...Z Normal or Inverted Frequency fixed crystal In the range 440 470MHz Frequency Stability 10ppm Channel Spacing 25KHz Frequency Deviation 4 5KHz Over Air Baud Rate fixed programmable 512 1200 2400 bps Sensitivity Maximum 512bps 6μV m 1200bps 7 5μV m 2400bps 8 5μV m Selectivity 52dB Image Rejection 52dB Spurious Rejection 60dB Intermodulation 52dB Relay Contact Max Rating 0 5A 125V ac 1A 60V dc Seri...

Страница 15: ...15 of 15 This page intentionally left blank ...

Страница 16: ...16 of 16 Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail support microframecorp com ...

Отзывы: