e) Serial Data Output
Where it is required to send message data for onward transmission or for logging purposes, the serial port
can be enabled. The RX10 can be programmed to accept either two individual RICs or a range of RICs.
Note: the RX10 does not provide time/date stamping, although this function could be facilitated using
suitable software on a PC, or by using a POS style printer with an onboard real time clock.
i) Serial Data – RIC 1 and RIC 2
Where individual RICs are selected, a specific beep type (A,B,C,D) must also be entered. When the chosen
RIC + beep type + message is transmitted, the message will be passed to the serial port.
ii) Serial Output Logger
A range of RICs can be entered, together with either a specific beep type or “All,” where any beep type is
valid. If the serial port is being used to pass data to a Scope transmitter (a repeater application), the tick
box “Scope Protocol Output Format” should be checked. This will output the Scope control codes + RIC in
front of the message. Where numeric messages are sent for onward transmission, the tick box “Interpret as
numeric messages” must be checked.