Microframe Corporation D8009 Скачать руководство пользователя страница 1

 

Time Code Sync Master 

Models 8009 & 8010 

 

 

 

 

 

 

 

 

 

 

 

Microframe Corporation 

Operating Manual 

*D8010-7010*

June 2014  Revision 1.1 

Содержание D8009

Страница 1: ...Time Code Sync Master Models 8009 8010 Microframe Corporation Operating Manual D8010 7010 June 2014 Revision 1 1 ...

Страница 2: ...upplied from Microframe is rated CL2 and is approved for indoor installation everywhere except plenum areas Life Support Policy Microframe s products are not authorized for use as components in life support devices or systems without the express written approval of the President of Microframe Corporation As used herein 1 Life support devices or systems are defined as systems which support or susta...

Страница 3: ...tions 4 Quick Tips 5 Setting the time and changing the settings 6 Using SMPTE Sync in and Sync out 8 Workflow Recommendations 8 Battery Life Essentials 9 D8009 vs D8010 Differences 10 Model D8009 Specifications 11 Model D8010 Specifications 12 Microframe Corporation Broken Arrow OK Tel 918 258 4839 Toll free 1 800 635 3811 www microframecorp com support microframecorp com ...

Страница 4: ...elected press or to change value When all options are correctly set hold down Mode ON to save and exit Do nothing for 15 seconds and the Sync Master Time Code Generator will revert back to normal operation and not save any option changes See back decal to change Time Sleep Sets Display time 5 to 60 Seconds Factory Default 15 Sec Rate Sets Frame rate 23 976 24 29 97 29 9DF 30 Factory Default 23 976...

Страница 5: ...brating the 2nd row will show the battery voltage Changing the Brightness Quick Change Tap the middle button to turn the display on While time code is displayed press the plus button to increase brightness or the minus button to decrease brightness Remember increased brightness uses more power and shortens the battery life during production Be sure to keep an eye on the battery level If you try to...

Страница 6: ... the screen blanks 5 60 seconds 2 Frame Rates 23 98 23 976 24 25 29 97 29DF drop frame 30 3 Percent brightness for the display Running at a high brightness will shorten the battery life 5 100 4 Flip the display direction Note the frame count ends up on the top row D8010 only Set Sleep Time The sleep time is actually how long the time is shown when the on button is pressed before the display goes b...

Страница 7: ... As a personal preference or for cable concerns one may want to change the orientation of the Sync Master to have the buttons on the right instead of on the left This can be achieved by simply changing the Flip memory location Setting this memory location to 1 instead of 0 will change the orientation of your display Simply get to Options mode by pressing and holding on and the unit will show SLEEP...

Страница 8: ...ins e Plugging devices D8010 only into AC wall power to sustain time code and preserve battery life 2 CHECK TIME CODE BEFORE FILMING A NEW SCENE This may vary depending on how many times locations are changed but may provide the following essential elements a Data Wranglers can document time code ranges with media files while copying to storage b Frequent time code snap shots are a great reference...

Страница 9: ...e the set brightness an led will blink indicating that the battery is not allowing the set brightness The Sync Master is designed to provide time code continuously and does not have an off switch Remove the battery when not in use USING THE AC ADAPTER Applies to the D8010 Only The AC wall adapter is NOT designed to charge any battery while connected to the Sync Master D8010 The AC adapter allows f...

Страница 10: ...s Digits 1 LED 10 s of hours plus 1 Digit 2 Digits to show up to 23 hours Dry Erase Area for Scene Notations NO YES External Power Option NO YES Flip Display Orientation Option NO YES Holster with Belt Clip Available YES NO LED Brightness Ultra Bright Regular Size Pocket Sized Portable ...

Страница 11: ...odel D8009 Specifications Power 9V Alkaline Battery Battery Life 4 12hrs depending on usage Typically 8 hrs Supported Frame Rates 23 976 24 25 29 97 29 97 DF 30 SMPTE Input Range 0 4Vpp to 5Vpp SMPTE Input Loading AC coupled signal into 33K SMPTE Output 3Vpp w no load AC coupled Weight 0 30lbs 0 14kg including 9V battery Dimensions 4 96 x 2 72 x 0 95 12 6cm x 6 9cm x 2 4cm Clock Accuracy 2ppm from...

Страница 12: ...dapter 1 Manual Model D8010 Specifications Model 8010 Model D8010 Specifications Power 9V Alkaline Battery Battery Life 4 12hrs depending on usage Typically 8 hrs Supported Frame Rates 23 976 24 25 29 97 29 97 DF 30 SMPTE Input Range 0 4Vpp to 5Vpp SMPTE Input Loading AC coupled signal into 33K SMPTE Output 3Vpp w no load AC coupled Weight 0 50lbs 0 23kg including 9V battery Dimensions 7 25 x 3 62...