ZLR964222L
Line Module User Guide
7
Microsemi Corporation Confidential and Proprietary
2.0 Quick Start Guide
2.1 Required Materials
The following materials will be required to set up the
ZLR964222L
line module system:
•
Le71HK0004 Telephony Applications Platform (ZTAP) Kit
with file system P1.14.0 or later (available from
Microsemi’s web site, OPN
Le71SDKZTAP
);
• Software tools downloaded from the Microsemi web site, including
MiToolkit
(OPN
Le71SDKTK
), release
P1.8.0 or later, and
Profile Wizard
(OPN
Le71SDKPRO
), release P2.4.0 or later;
•
ZLR964222L
line module;
• Two analog telephone sets; and
• Two RJ-11 telephone cords.
Refer to
for a listing of the essential
MiToolkit
applications.
Application
Operating
Functions
Description
VP-Script
ZTAP
Control
ZTAP
software image update; Tcl script editing and execution; console and
terminal communication
Mini-PBX
Main Window /
Stand-Alone
Visual PBX
Discovers modules and assigns extension numbers and termination types
(FXS or FXO) for each hardware port; Initializes the
Call Control
application
with the profiles parameters found on the Module ID (MID) for each of the
installed modules; Displays real-time status and
VP-API-II
line states for all
extensions; Enables calling from any FXS into any other FXS or an FXO port.
Profile
Parameter
Loading
By clicking on any extension displayed on the
Mini-PBX
main window,
Profile
Wizard
-generated files may be loaded and applied to the port associated with
that extension. Profiles include AC and DC coefficients, Ringing parameters,
FXO / Dialing parameters, etc.
Half Channel
Setup and
Testing
By clicking on any extension displayed on the
Mini-PBX
main window, the
following half-channel functions are available: a) Manual line state control, b)
PCM time slot assignment, and c) RX and TX gain adjustment. These
functions enable AC and DC functional testing by placing the channel into one
of the
VP-API-II
system states and connecting the PCM highway to the E1/T1
interface on the
ZTAP
platform.
Line Testing
Clicking on any FXS extension displayed on the
Mini-PBX
main window and
selecting the Line Testing tab provides access to
VeriVoice
tests. Tests such
as line voltage, receiver off-hook, resistive faults, and ringer equivalence
number (REN) may be run on that port.
VP-API-II
Line
Debug
By clicking on the
Terminal
menu item, a terminal application is launched
allowing the user to type commands and view
VP-API-II
run-time
debug
messages. The
VP-API-II
function
VpSetOption()
with
VP_OPTION_ID_DEBUG_SELECT
is used to enable debug messages.
Table 1 - Essential MiToolkit Applications