15
Push the UP button in SOLAR mode you can then access the battery run to menu:
(This allows the user to set the level the battery will go down to before switching to mains
power.)
Battery Run To:
48v System – 46v (Default) (Can be changed in 2v Increments)
36v System – 34.5v (Default) (Can be changed in 1.5v Increments)
24v System – 23v (Default) (Can be changed in 1v Increments)
12v System – 11.5v (Default) (Can be changed in 0.5v Increments)
Push the ENTER button. The Menu settings can be changed.
Push the UP button. The menu changes to AC RUN TO menu:
(Allows the user to set the level the mains will charge the battery to before the inverter
switches back to battery power.)
AC Run To:
48v System – 54.4v (Default) (Can be changed in 2v Increments)
36v System – 40.5v (Default) (Can be changed in 1.5v Increments)
24v System – 24v (Default) (Can be changed in 1v Increments)
12v System – 12v (Default) (Can be changed in 0.5v Increments)
Push the ENTER button. The Menu settings can be changed.
SOLAR
CONTROL
AC
RUN TO
54.4v
MICROCARE
ON
OFF
ENTER
Menu Down
Menu Up
OK
Inverter
Error
SOLAR
CONTROL
BAT RUN TO
46.0v
MICROCARE
ON
OFF
ENTER
Menu Down
Menu Up
OK
Inverter
Error