6.Calibration
(1) Install the radar correctly according to the installation instructions in
subsection 2.
(2) Open the debug software on the host computerand select CAN device as
USBCAN_2E_U with baud rate of 500K as shown in figure 4.
Figure 4 Upper computer software setting
(3) Place the corner reflector at 6 meters (±0.3) in front of the radar, and the left
and right offset is less than 0.2
(4) Click measurement button. If the radar feedback position is placed
successfully within the scope of the second complement, the calibration can
start. Otherwise, the corner reflector or the installation position of the radar
should be reset.