background image

Users Manual & Installation Guide  

PV-

 SERIES 

4-P

ORT 

RS232/RS422/RS485 

 

Page 4 of 7

 

I

NSTALLATION 

G

UIDE

 

 

Please refer to the schematic outline on page 5. 

 

P

RECAUTIONS TO 

ESD 

 

Please  note,  that  the  Micronix  PV  modules  must  be  handled  with  respect  to  ESD  (Electrostatic  Discharge). 

Electrostatic Discharge to the PV modules must be avoided.  

Before  removing  the  module  from  the  protection  bag,  the  user  must  be  discharged  using  a  grounded  wrist 

ribbon. 

 

S

ETTING THE 

I/O

 

A

DDRESS

 

 

The I/O address for channel A through D is set by the corresponding rotary-switch. 

The individual positions are printed on the PCB.

 

E

XAMPLE

 

Setting channel A to I/O address 2F8, turn rotary-switch labelled "A" to position "7". 

 

S

ETTING THE 

I

NTERRUPT 

N

UMBER 

(I

NDIVIDUALLY

 

The IRQ number for channel A through D, is set by the corresponding pin column array. 

The individual positions are printed on the PCB. 

E

XAMPLE

 

See IRQ select page 6. 

 

S

ETTING THE 

I

NTERRUPT 

N

UMBER 

(S

HARED

 

If shared interrupt is used, the IRQ number for all four channels will be the same. 

E

XAMPLE

 

See shared IRQ settings page 7. 

 

S

ETTING THE 

B

AUD RATE

 

 

The baud rate is set by the software application. Each port is compatible to a normal PC COM-port and should 

be accessed accordingly. Operating systems and standard software applications have utilities for that. 

 

For  more  sophisticated  programming  and  specific  control  of  handshake  signals,  please  refer  to  a  16C550 

manual. This manual can be ordered from a National Semiconductor representative. 

 

H

IGH 

S

PEED

-

VERSIONS

:

  

B

AUD RATE 

N

OTICE

 

 

The actual baud rate will be 4 times the baud rate set by the software.

 

 

5V

 ONLY VERSIONS 

(5

V

): 

 

These versions do not r/-12V from the PC/104 bus.

 

Содержание Micronix PV Series

Страница 1: ...el 45 6615 3000 Fax 45 6615 3077 E mail support micro technic com Website www micro technic com MICRONIX PC 104 SERIAL INTERFACE PV SERIES 4 PORT RS232 RS422 RS485 MODULES User Manual Installation Guide VERS 1 04 DOC M4801DM DOC ...

Страница 2: ... or stackthrough S versions connectors are available FEATURES AND SPECIFICATIONS Four channels of asynchronous serial communication Baud rate up to 115 Kbps or 460 Kbps H versions 16C550 or 16C650 advanced UART with 16 byte FIFO Supports RS232 interface TxD RxD RTS CTS DTR DSR DCD GND Complete RS 232 Modem control signals except RI RTS used for data direction control Interrupt selectable IRQ 3 4 5...

Страница 3: ...cription Type PV 0301 H S 3xRS485 2 wire 1xRS422 PV 0310 H S 3xRS485 2 wire 1xRS485 4 wire PV 1201 H S 1xRS232 2xRS485 2 wire 1xRS422 PV 1210 H S 1xRS232 2xRS485 2 wire 1xRS485 4 wire PV 2002 H S 2xRS232 2xRS422 PV 2011 H S 2xRS232 1xRS485 4 wire 1xRS422 PV 2101 H S 2xRS232 1xRS485 2 wire 1xRS422 PV 2110 H S 2xRS232 1xRS485 2 wire 1xRS485 4 wire PV 3001 H S 3xRS232 1xRS422 PV 3010 H S 3xRS232 1xRS...

Страница 4: ...LLY The IRQ number for channel A through D is set by the corresponding pin column array The individual positions are printed on the PCB EXAMPLE See IRQ select page 6 SETTING THE INTERRUPT NUMBER SHARED If shared interrupt is used the IRQ number for all four channels will be the same EXAMPLE See shared IRQ settings page 7 SETTING THE BAUD RATE The baud rate is set by the software application Each p...

Страница 5: ...7 SCHEMATIC OUTLINE 1 DCD 2 RxD 3 TxD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI RS232 IRQ SELECT Pin column array I O ADDRESS SELECT Rotary switch RS485 4 2 RS422 RS232 RS485 2 RS422 RS232 RS232 RS485 2 RS232 RS485 2 3 Tx 4 Rx 5 GND 8 Tx 9 RX RS422 3 DATA 4 RTS 5 GND 8 DATA 9 RTS RS485 ...

Страница 6: ...PORT RS232 RS422 RS485 Page 6 of 7 Individually IRQ settings CH A IRQ10 CH B IRQ5 CH C IRQ9 CH D IRQ15 Shared IRQ settings CH A IRQ5 CH B IRQ5 CH C IRQ5 CH D IRQ5 Important notice It is NOT possible to combine individually and shared IRQ settings ...

Страница 7: ... 4 PORT RS232 RS422 RS485 Page 7 of 7 OPTIONAL CABLE 20CM RS 232 CONNECTOR DSUB 9 male rib422 dwg 5 4 3 2 1 6 7 9 8 GND Rx Rx Tx Tx Not used Leoco 2540S 10 10 way ribbon cable RS 422 CONNECTOR RS 485 CONNECTOR Coding key in this position Pin 1 ...

Отзывы: