18
8.
Faults and remedies
Type of fault
Possible causes
Remedy
smartDRAFT Dispense
the front part of the smartDRAFT Dis-
attach the smartDRAFT Dispense Head
Head does not fi t on the pense head does not lie in the cut-out
so that the front part fi ts in the cut-out
smartDRAFT KEG
in the top ring of the smartDRAFT KEG of the top ring
the smartDRAFT Dispense Head
completely withdrawn the smartDRAFT
was not attached completely withdraw Dispense Head and attach it on the KEG
smartDRAFT TAP is not smartDRAFT TAP is not attached
please refer to instruction on
working
properly
page 9
too much foam
smartDRAFT KEG has not been
pre-cool smartDRAFT KEG and
pre-cooled
pay attention to LED display
and wait until the KEG has reached
8°C.
drink is too warm
dispensing temp. not yet reached
wait until LED Display has reached
8°C
door of smartDRAFT Cooler are
close door until you hear locking
not properly closed
clip click into place
smartDRAFT KEG has not been
pre-cool smartDRAFT KEG and,
pre-cooled
cooling fan motor dirty or defective
inform service technician
ventilation grille is covered
uncover grille
unit placed too close to a wall
ensure suffi cient distance
refrigeration circuit leaks or the
inform service technician
compressor is defective
compressor does not work compressor is not switched on
inform service technician
or is defective
cooling fi ns in the
door of smartDRAFT Cooler are
remove the plug from the power
smartDRAFT Cooler are not properly closed
supply, allow the fi ns to defrost.
covered in ice
Mop up any moisture with a soft
cloth. Always close the door
smartDRAFT Cooler has been
remove the plug from the power
operated without a KEG
supply, allow the fi ns to defrost.
Mop up any moisture with a soft
cloth. smartDRAFT Cooler
may only be operated with a
smartDRAFT
KEG