background image

2.1 LOCATION

•   Be sure the location chosen has a floor strong enough to support the total weight of the 

unit and contents. 

•  Recommended to use a professional installation company. 
•  For the most efficient operation, be sure to provide good air circulation around the unit.
•  MDD23W cannot be used for built-in applications.
•  Avoid hot corners and locations near stoves and ovens. 
•  It is recommended the unit be installed no closer than 2" from any wall. 
•  The place for the dispenser must be open and free of dust and debris.

2.2 INSTALL WINE TOWER (SOLD SEPARATELY)

•  Place rubber washer over draft tower mounting holes in cabinet top. 
•  Place wine line down through holes. 
•  Secure font with four bolts provided. 
•  Attach keg connectors to wine lines (provided with wine font).

2.3 INSTALL KEG TAPPING KIT(S) (SOLD SEPARATELY)

Use only Wine Certified components for wine dispensing. This includes grade 304-grade 
stainless steel or better and Barriermaster™ Flavourlock tubing. Use of these components 
assures vintners quality.

2

LOCATION AND

INSTALLATION

Use John Guest swivel 
elbows to minimize line 
kinking. Use zip ties to 
secure to gas line (blue 
hose) to John Guest fitting.

|   5

MICROMATIC.COM

SUPPORT  (888) 864-9400

Содержание PRO-LINE WINE MDD23W Series

Страница 1: ...INSTRUCTIONS COMPLETELY Before getting started please read this user manual and at all times follow the important safety instructions PRO LINE WINE INSTALLATION USE MAINTENANCE GUIDE DUAL TEMPERATURE...

Страница 2: ...AGE 8 4 2 SERVING 8 4 3 MMD23W AIR AND WINE TEMPERATURES 9 5 THERMOSTAT ADJUSTMENT 10 6 DATA PLATE 14 7 ELECTRICAL CONNECTIONS 14 8 TROUBLESHOOTING 15 9 MAINTENANCE 16 9 1 CLEANING THE CABINET 16 9 2...

Страница 3: ...ntil poured INCREASE SALES Dispense Wine any place any time Capture incremental sales Open up new opportunities for profitability DISPENSE QUALITY WINE Pour consistency from the first to the last glas...

Страница 4: ...g there is concealed damage to the equipment notify the carrier immediately Notification should be made verbally as well as in written form Request an inspection by the shipping company of the damaged...

Страница 5: ...of dust and debris 2 2 INSTALL WINE TOWER SOLD SEPARATELY Place rubber washer over draft tower mounting holes in cabinet top Place wine line down through holes Secure font with four bolts provided Att...

Страница 6: ...steel front sides and back INTERIOR 20 gauge stainless steel floor rugged false floor reinforced frame 24 gauge galvanized walls VENTILATION Front and side ventilated PLUMBING Automatic condensate eva...

Страница 7: ...e steel front sides and back INTERIOR 20 gauge stainless steel floor rugged false floor reinforced frame 24 gauge galvanized walls VENTILATION Rear ventilated PLUMBING Automatic condensate evaporator...

Страница 8: ...in the bottom of a wine glass 4 2 SERVING Pro Line Wine units are designed to maintain your wine keg temperature within the vintners recommended temperature serving range White wines 45 F range 40 45...

Страница 9: ...4 3 MDD23W AIR AND WINE TEMPERATURES This chart shows that air temperature cycles but keg liquid temperature remains consistent 9 MICROMATIC COM SUPPORT 888 864 9400...

Страница 10: ...led AC parameter On Defrost in progress Flashing Dripping in progress On Measurement unit Flashing Programming mode On Measurement unit Flashing Programming mode To display target set point in program...

Страница 11: ...n 15 seconds without pressing a key NOTE The set number is stored even when the procedure is exited by waiting for the time out to expire HOW TO ENTER THE HIDDEN MENU 1 Enter the programming mode by p...

Страница 12: ...sor OFF time with faulty probe 12 30 CF Temperature measurement units F F rE Resolution only for C in in Ld Default display P1 P1 dy Display delay 5 2 dE Defrost termination temperature 50 60 id Inter...

Страница 13: ...n Compressor OFF time with faulty probe 12 30 CF Temperature measurement units F F rE Resolution only for C in in Ld Default display P1 P1 dy Display delay 5 2 dE Defrost termination temperature 50 60...

Страница 14: ...al code or the National Electrical Code to be sure unit is connected to the proper power source Verify correct incoming voltage according to the Data Plate information A protected circuit of the corre...

Страница 15: ...thermostats on the Pro Line Wine units have been factory preset at approximately 45 F for white wine dispensing and 55 F for red wine dispensing Any change to the factory settings will affect performa...

Страница 16: ...it off and allow to defrost Make sure the door closes properly and gasket seals completely as warm air entering the unit will cause evaporator to freeze and malfunction Do not use a pick knife etc to...

Страница 17: ...m soapy water Avoid full strength cleaning products on the gasket as this can cause it to become brittle and prevent a proper seal Never use sharp tools or knives to scrape or clean the gasket which c...

Страница 18: ...d Color Green Dark Blue Brown Light Blue Brown Dark Blue Yellow Red Black Black White White White Black Black Striped 10 WIRING DIAGRAMS MDD23W SERIES 18 PRO LINE WINE INSTALLATION USE AND MAINTENANCE...

Страница 19: ...Standard Color Green Dark Blue Brown Light Blue Brown Dark Blue Yellow Red Black White White Black Black Striped Black White MDD58W SERIES 19 MICROMATIC COM SUPPORT 888 864 9400...

Страница 20: ...54 Black Right Door Kit 1 M16901M0153 Black Left Door Kit 1 7 604501M0019 Door Central Gasket 1 604501M0007 Door Gasket 1 1 8 603301M0056 Lock Master Key 1 603301M0173 Lock Master Key 2 9 M16909M0020...

Страница 21: ...1 Racks 25 600301M0032 Plastic Bottom Protector 2 26 M18101M0337 Top MDD23W 1 M18101M0264 Top MDD58W 1 CO2 Distributor 29 604313M0002 Air Distributor 4 Ways 2 Handles 30 603301M0155 Black Handle Door...

Страница 22: ...ions set forth in this warranty have been satisfied and whether or not the applicable warranty is in effect WHAT IS NOT COVERED BY THIS WARRANTY All repairs must be first authorized by Micro Matic per...

Страница 23: ...NOTES 23 MICROMATIC COM SUPPORT 888 864 9400...

Страница 24: ...Toll Free 1 866 327 4159 www micromatic com 02283 MM M 0822 2022 Micro Matic USA Inc All Rights Reserved...

Отзывы: