background image

MICROMATIC.COM   |   866-327-4159        

 

 

 

 

 

 

 

       REMOTE POWER PACK SERVICE MANUAL

   

|

   9

ELECTRONIC TEMPERATURE CONTROL WITH DISPLAY

        NOTE: When the unit leaves the factory the electronic thermostat is pre-set to the following parameters:

  

 

Temperature Scale:

F (Fahrenheit)

Setpoint:

29° F

Differential:

3° F

 

Temperature Scale:

F (Fahrenheit)

Setpoint:

28° F

Differential:

5° F

        NOTE

: To ensure the correct operation of your unit these parameters must be adhered to.

User/customer can change the temperature by pressing the up and down arrows.

SERIES MMP4305 AND MMPP4307

CHANGING GLYCOL PUMP

Note: A pinch off tool is required to complete this repair

1.   Unplug unit from receptacle.
2.   Pinch off glycol supply line to bottom of pump allowing enough room to remove clamp safely.
3.   Hold pump firmly and loosen clamp between pump and motor.
4.   With clamp loose remove pump and drive key.
5.   Install new key and pump by reattaching clamp making sure alignment of key is correct between pump and motor.
6.   Reattach glycol supply hose and install clamp.
7.   Remove pinch off tool and plug unit into receptacle.

Содержание MMPP4302-PKG-R

Страница 1: ...MMPP4302 R MMPP4302 PKG R MMPP4303 PKG R MMPP4303 PKG 3 R MMPP4305 PKG R MMPP4305 PKG 3 R MMPP4307 PKG R MMPP4307 PKG 3 R MMPP4307 PKG 4 R REMOTE POWER PACK SERVICE MANUAL v1 0 ...

Страница 2: ...2 REMOTE POWER PACK SERVICE MANUAL MICROMATIC COM 866 327 4159 ...

Страница 3: ...PACK SERVICE MANUAL 3 EQUIPMENT SPECIFICATIONS 4 5 INSTALLATION 6 8 MAINTENANCE 8 CHANGING GLYCOL PUMP 9 REPLACING MOTOR 10 REPLACING THERMOSTAT 10 TROUBLESHOOTING 11 SPARE PARTS 12 WIRING DIAGRAMS 13 WARRANTY INFORMATION 15 TABLE OF CONTENTS ...

Страница 4: ...igh 18 low 140 high 18 low 140 high 18 low 140 high 18 low 140 high Dimensions L x W x H Including pump s and motor s 30 x 18 x 29 75 30 x 18 x 29 75 30 x 18 x 29 75 30 x 18 x 29 75 37 12 x 18 75 x 31 15 Weight lbs 71 kg 157 lbs 71 kg 157 lbs 80 kg 175 lbs 91 kg 200 lbs 98 kg 215 lbs Bath Capacity gal 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L Bath Insulation T...

Страница 5: ...8 low 140 high 55 low 260 high 55 low 260 high 55 low 260 high Dimensions L x W x H Including pump s and motor s 37 12 x 18 75 x 31 15 38 x 20 x 36 38 x 30 x 36 30 x 18 x 29 75 Weight lbs 131 kg 290 lbs 134 kg 295 lbs 134 kg 295 lbs 91 kg 200 lbs Bath Capacity gal 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L Bath Insulation Thickness 1 5 1 5 1 5 1 5 Inlet Water Pressure NA NA NA...

Страница 6: ...es from the trunk line to the pump outlet Insulate any exposed tubing NOTE In units with more than one pump connect a glycol line to each pump outlet 4 Connect the second glycol line from each circuit to the glycol bath inlet 5 Fill the glycol bath with Micro Matic Polar Flo glycol solution MMPP4302 R MMPP4302 PKG R MMPP4303 PKG R MMPP4303 PKG 3 R Mix 2 parts water to 1 part glycol MMPP4305 PKG R ...

Страница 7: ...up of condensing unit REFRIGERANT PIPING The condensing unit must remain sealed until piping is complete and final connections are ready to be made Use only refrigeration grade copper tubing ACR Type L bright annealed dehydrated and properly sealed against contamination Take caution to keep refrigeration tubing clean and dry prior to installation Suction lines should slope down for each 10 feet of...

Страница 8: ...ner the unit should be checked for electrical safety When all refrigeration line connections have been made the complete system should be leak checked EVACUATION AND START UP A vacuum of 250 microns or less must be pulled to properly dehydrate the system DO NOT USE THE SYSTEM COMPRESSOR AS A VACUUM PUMP DO NOT OPERATE THE COMPRESSOR WHILE THE SYSTEM IS IN A VACUUM Open all condensing unit service ...

Страница 9: ...User customer can change the temperature by pressing the up and down arrows SERIES MMP4305 AND MMPP4307 CHANGING GLYCOL PUMP Note A pinch off tool is required to complete this repair 1 Unplug unit from receptacle 2 Pinch off glycol supply line to bottom of pump allowing enough room to remove clamp safely 3 Hold pump firmly and loosen clamp between pump and motor 4 With clamp loose remove pump and ...

Страница 10: ...nections Reattach cord to new motor by affixing ground wire to green ground screw and plugging 2 wires to motor connections Place cord in electrical wire channel in motor housing and reattach electrical connection cover plate 8 Plug cord into receptacle REPLACING THERMOSTAT 1 Unplug unit from receptacle 2 Remove the screws holding the thermostat housing to the unit Slide the white plastic brackets...

Страница 11: ...ure to use correct relay will cause compressor failure C Compressor malfunction C Replace compressor 5 Warm beer A Defective Pump check motor also A Check return line in reservoir for liquid flow Replace pump on 125 250 and 500 units Check condition of key between pump and motor B Defective motor check pump also B Replace motor C Refrigeration unit not running C Refer to 2 D Trunk lines located in...

Страница 12: ...lt MMPP4305 M X X X Vane Pump Key MM 3362 2 X X X X X Clamp Pump Connectors MM BC3 KIT X X X X X Nipple for Vane Pump Straight 617C X X X X X Vertical Pump MMPP4301 EPVP X Thermostat Danfoss ERC 112C MMPP080G3206 X X X X X X Compressor MPP4301 Series MMPP4301 EP C X X Refrigeration Deck MPP4301 Series MMPP4301 UPPER X Refrigeration Deck MPP4302 Series MMPP4302 UPPER X Compressor MPP4302 Series MMP...

Страница 13: ...MICROMATIC COM 866 327 4159 REMOTE POWER PACK SERVICE MANUAL 13 WIRING DIAGRAMS ...

Страница 14: ...14 REMOTE POWER PACK SERVICE MANUAL MICROMATIC COM 866 327 4159 NOTES ...

Страница 15: ...n subject to misuse neglect alteration accident unauthorized service abuse or to any damage caused by transportation This warranty does not cover items subject to normal wear and tear gaskets seals o rings etc PURCHASER RESPONSIBILITY Except as expressly provided in this Agreement Purchaser assumes all other responsibility for any loss damage or injury to persons or property arising out of connect...

Страница 16: ...02035 R MM M 0519 2019 Micro Matic USA Inc All Rights Reserved Micro Matic reserves the right to change specifications without notice ...

Отзывы: