background image

3

SPECIFICATIONS 

& KEG FOOTPRINTS

DIRECT DRAW MODELS

BACK BAR MODELS

MODEL

DOORS

TOWER*

FAUCETS

KEGS

HP

AMP

CRATED 

WEIGHT 

(LBS)

LENGTH

WIDTH

HEIGHT

BTU

REFRIGERANT 

CHARGE

(R-134 A)

MDD17-E

1

1

1

1

1/6

2.5

138

17.5"

30"

38"

850

5.3 oz

MDD23-E

1

1

1

1

1/6

2.5

172

25"

30"

40.5"

850

5.64 oz

MDD36-E

1

1

1

1

1/6

3.6 

172

36 3/4"

29 1/2" 

36 7/8"

850

6.35 oz

MDD58-E

2

2

3

3

1/3

6.5

318

59 1/2"

29 1/2"

36 7/8"

2400

  9.8 oz

MDD68-E

2

2

3

3

1/3

6.5

359

69 1/2"

29 1/2"

36 7/8"

2400

  9.8 oz

MDD78-E

3

2

4

4

1/3

6.5

377

80"

29 1/2"

36 7/8"

2400

  9.8 oz

MDD94-E

3

2

4

5

1/3

6.5

406

95 1/2"

29 1/2"

36 7/8"

2400

  9.8 oz

VOLTAGE 115V 60HZ   *TOWER SOLD SEPARATELY

MODEL

DOORS

SHELVES

KEGS

HP

AMP

CRATED 

WEIGHT 

(LBS)

LENGTH

WIDTH

HEIGHT

BTU

REFRIGERANT 

CHARGE

(R-134 A)

MBB36-E

1

1

1

1/6

3.6 

172

36 3/4"

29 1/2" 

36 7/8"

850

6.35 oz

MBB58-E

2

2 (Flat) / 2 (Rails)

3

1/3

6.5

318

59 1/2"

29 1/2"

36 7/8"

2400

  9.8 oz

MBB68-E

2

2 (Flat) / 2 (Rails)

3

1/3

6.5

359

69 1/2"

29 1/2"

36 7/8"

2400

  9.8 oz

MBB78-E

3

2 (Flat) / 4 (Rails)

4

1/3

6.5

377

80"

29 1/2"

36 7/8"

2400

  9.8 oz

MBB94-E

3

2 (Flat) / 4 (Rails)

5

1/3

6.5

406

95 1/2"

29 1/2"

36 7/8"

2400

  9.8 oz

VOLTAGE 115V 60HZ

|   6

PRO-LINE E-SERIES REFRIGERATION USER GUIDE AND SET UP MANUAL  

1/2

1/4

1/4

SLIM

1/4

SLIM

1/6 1/6

1/6 1/6

1/2

1/2

1/2

1/6

1/6

1/6

1/6

1/6

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/2

1/4

1/4

SLIM

1/4

SLIM

1/6 1/6

1/6 1/6

1/2

1/2

1/2

1/6

1/6

1/6

1/6

1/6

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/4

SLIM

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

1/6

KEG FOOTPRINTS

16 1/8"

1/4 BARREL

1/2 BARREL

16 1/8" 

1/4 SLIM BARREL 

11 1/8" 

1/6 BARREL

9 1/4"

Содержание MBB36-E

Страница 1: ...RSION 2 0 SAFETY FIRST READ INSTRUCTIONS COMPLETELY Before getting started please read this user manual and at all times follow the important safety instructions PRO LINE E SERIES USER MANUAL SET UP GUIDE ...

Страница 2: ... TEMPERATURE CONTROL 9 5 2 DESCRIPTION OF BUTTONS ON THE CONTROLLER 10 5 3 ELECTRONIC TEMPERATURE CONTROL 11 5 4 DEFROST 11 6 MAINTENANCE 11 6 1 STAINLESS STEEL CARE AND CLEANING 11 6 2 CLEANING THE CONDENSER COIL 12 6 3 DRAIN MAINTENANCE 12 6 4 INSTALLING AIR CHANNEL S AND DRAFT TOWER S 13 6 5 INSTALLING GLASS RINSER WATER INLET 13 7 TROUBLESHOOTING 14 8 WIRING DIAGRAMS 15 9 WARRANTY 16 TABLE OF ...

Страница 3: ... 3 MICROMATIC COM SUPPORT 888 864 9400 MDD78S E As Shown ...

Страница 4: ...AL PROPERTY AND COPYRIGHT PROTECTION All rights reserved Any including but not limited to duplication dissemination and other uses of the texts graphics or other representations without the consent of the manufacturer Contact Information Micro Matic USA Inc 2364 Simon Court Brooksville FL 34604 1 4 CUSTOMER SERVICE If further technical information is needed please contact the Service Department di...

Страница 5: ...l crating material until inspection has been made Finally contact Micro Matic Open the compressor compartment housing and visually inspect package Be sure lines are secure and base is intact A NOTE FROM OUR QUALITY CONTROL MANAGER Congratulations on your new purchase We would like to welcome you to the Micro Matic family The unit in front of you is a great piece of equipment that will become one o...

Страница 6: ...1 2 36 7 8 2400 9 8 oz VOLTAGE 115V 60HZ 6 PRO LINE E SERIES REFRIGERATION USER GUIDE AND SET UP MANUAL 1 2 1 4 1 4 SLIM 1 4 SLIM 1 6 1 6 1 6 1 6 1 2 1 2 1 2 1 6 1 6 1 6 1 6 1 6 1 4 SLIM 1 4 SLIM 1 4 SLIM 1 4 SLIM 1 4 SLIM 1 4 SLIM 1 4 SLIM 1 4 SLIM 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 2 1 2 1 2 1 2 1 4 SLIM 1 4 SLIM 1 6 1 6 1 6 1 6 1 2 1 4 1 4 SLIM 1 4 SLIM 1 6 1 6 1 6 1 6 1 2 1 2 1 2 1 6 1 6 1 6 1 ...

Страница 7: ...r temperature within the most desirable range of 34 to 38 F You can expect this temperature with the proper temperature control setting and in a normal environment It is important to understand that when the beer is purchased it must be installed inside the cooler as soon as possible to avoid excessive warm up of the beer Leave untapped for 24 hours to allow for proper cooling No provision is made...

Страница 8: ... left corner Under no circumstances should the data plate be removed from the unit The data plate is essential to identify the particular features of your unit and is of great benefit to installers operators and maintenance personnel 4 6 ELECTRICAL CONNECTIONS Refer to the amperage data in this manual or on data plate and your local code or the National Electrical Code to be sure unit is connected...

Страница 9: ...still have power while the thermostat is in the OFF position The knob of the thermostat is the temperature controller This is located inside the cabinet Please be sure that the knob of thermostat is pointing to the yellow arrow Figure 3 This position is recommended by the factory to assure correct function of the equipment see Figure 1 below NOTE Keep in mind if you move the knob to a different po...

Страница 10: ...pressor enabled Flashing Anti short cycle delay enabled AC parameter On Defrost in progress Flashing Dripping in progress On Measurement unit Flashing Programming mode On Measurement unit Flashing Programming mode SYMBOL OPERATION SYMBOL OPERATION To display target set point in programming mode it selects a parameter or confirms an operation In programming mode it browses the parameter codes or in...

Страница 11: ...hen the equipment will begin the defrost cycle 6 MAINTENANCE 6 1 STAINLESS STEEL CARE AND CLEANING Proper cleaning of stainless steel requires soft cloths never use steel pads wire brushes or scrapers Cleaning solutions need to be alkaline or non chloride cleaners Any cleaner containing chlorides will damage the protective film of the stainless steel Chlorides are also commonly found in hard water...

Страница 12: ... and excessive run times Continuous operation with dirty or clogged condenser coils can result in compressor failures Neglecting the condenser coil cleaning procedures WILL VOID YOUR WARRANTY associated with the compressor or cost to replace the compressor 6 3 DRAIN MAINTENANCE Each unit has a drain located inside the unit which removes the condensation from the evaporator coil and evaporates it a...

Страница 13: ...ound inside of the equipment STEP 4 Introduce the COLD AIR HOSE Figure 4 which is found inside of the equipment into the tower s base hole Push the cold air hose as far as possible up into the tower body Be sure and secure cold air hose by hooking on to beer hose elbow 6 5 GLASS RINSER WATER INLET INSTALLATION Always check local plumbing codes first Install in line water regulator 1750352C set at ...

Страница 14: ...ion and door is sealed Check fan is moving Don t put any food inside until unit is at temperature THERE IS WATER UNDER THE REFRIGERATOR Verify the condensor drain pipe is over the pan Check cabinet is level Sometimes working failures are due to simple causes which can be solved by the user Before asking for the help of a qualified technician please review the points below These failures are not co...

Страница 15: ...COND FAN WHT BLK BLK BLK LAMP s Piloto LIGHT SWITCH BROWN BLUE WHITE BLUE EVAP FAN BLUE GDN GDN BROWN AMB PROBE BLUE BLK STRIPED BLK SMOOTH BLK SMOOTH BLK SMOOTH BLK STRIPED ROCKER SWITCH BLUE BROWN JUNCTION BOX LINE NEUTRE BROWN NEUTRE SIGNAL FROM CONTROLLER BLUE NOTE THE LAMP IS ONLY INCLUDED FOR GLASS DOOR MODELS CHECK WITH YOUR SALES REPRESENTATIVE 15 MICROMATIC COM SUPPORT 888 864 9400 ...

Страница 16: ...he property of Micro Matic Micro Matic will have no responsibility to honor claims received after the date the applicable Warranty expires Notwithstanding the foregoing any claim with reference to the Equipment or any parts therefore for any cause shall be deemed waived unless submitted by the User to Micro Matic within thirty 30 days after the date the User discovered or should have discovered th...

Отзывы: