Micro Innovation MSystem GF0 Скачать руководство пользователя страница 14

Device description GF0

 

MICRO PANEL

Mounting instructions

 

 

 

 
14

 

Technical subject to change

M000235-01.DOC

© by Micro Innovation

 

5 M

OUNTING INSTRUCTIONS

 

5.1 M

OUNTING 

(

WITHOUT SPECIAL DEGREE OF PROTECTION

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.  Fit the front seal from the rear of the device.  
2.  Insert the Micro Panel GF0 into the panel cutout from the front (without any force).  
3.  The front seal must fit evenly between the front plate and the front panel.  
4.  Screw the countersunk screws on the device through the front panel into the corresponding nuts. 

The countersunk screws must be tightened evenly and securely. 

 
Observe the general mounting instructions (

 Section 4.1). 

 
 

5.2 M

OUNTING ACCORDING TO DEGREE OF PROTECTION 

IP 65 

 
An additional mounting kit is available for mounting devices with 4-hole aluminium fronts in 
accordance with IP65  (

 Section 17). This consists of a conter frame that is fitted at the back of the 

front panel so that the required pressure on the seal is ensured even when fitting to a thin panel.  
The conter frame must be ordered separately. 
 
Conter frame for GF0-57xxx-xx0, MDS Order No. : 65 18 972060 
Conter frame for GF0-10xxx-xx0, MDS Order No. : 65 20 963100 

Countersunk screws 

Micro Panel GF0 

 

Front seal 

Front panel cutout 

Nuts 

 

efesotomasyon.com - Klockner Moeller - inverter

Содержание MSystem GF0

Страница 1: ...scription Micro Innovation AG x Spinnereistrasse 8 14 x CH 9008 St Gallen x Switzerland Tel 41 0 71 243 24 24 x Fax 41 0 71 243 24 90 www microinnovation com x info microinnovation com GF0 efesotomasy...

Страница 2: ...tion as well as distribution to third parties can only be made with the express permission of Micro Innovation AG Micro Innovation AG does not accept any liability for damages arising from the use of...

Страница 3: ...Innovation AG Warning No warranty claims will be recognized for faults arising from the improper handling of any device Devices and communication should not be used for the implementation of any safe...

Страница 4: ...system power supply 15 7 Connection to the communication interface 16 7 1 Preparing the connection cable EMC 16 7 2 Preparing the shield connections 17 8 Connection and function of the programming por...

Страница 5: ...ubject to change M000235 01 DOC by Micro Innovation 5 14 Display 27 15 Maintenance and repair 28 16 Disposal 29 17 Technical data 30 18 EC Conformity 32 19 UL Listing 33 20 Revision History 34 efesoto...

Страница 6: ...or damage to property may occur if the relevant precautionary measures are not observed The individual Warning pictogrammes have the following meaning Caution General This type of warning must be obse...

Страница 7: ...he Micro Panel GF0 Download is implemented via a serial interface The project data is then stored inside the device in a retentive memory The Micro Panel GF0 is provided with a slot for the communicat...

Страница 8: ...wing front plate versions are available xx0 Device types with 4 hole aluminium front Section 4 1 xx1 Device types with corrosion resistant stainless steel front 1 4301 Section 4 1 xx2 Device types wit...

Страница 9: ...utton Section 9 All mounting versions allow protection in compliance with IP65 Section 5 2 The Micro Panel GF0 can be operated at an ambient temperature of up to 50 C Section 17 The ambient temperatur...

Страница 10: ...5 144 The figure above shows the dimensions of the GF0 57xxx xx0 devices These units are provided with a four hole aluminium front The devices with threaded bolts xx1 xx3 have identical outer dimensi...

Страница 11: ...ICES Cutout and hole pattern for device versions with 4 hole aluminium front xx0 Front panel cutout 203x147mm centrally to fixing holes Fixing screws M4 countersunk screw Cutout and hole pattern for d...

Страница 12: ...AL 7016 The figure above shows the dimensions of the GF0 10xxx xx0 devices These units are provided with a four hole aluminium front The devices with threaded bolts xx1 xx3 have identical outer dimens...

Страница 13: ...ES Cutout and hole pattern for device versions with 4 hole aluminium front xx0 Front panel cutout 316x244 mm centrally to fixing holes Fixing screws M5 countersunk screw Cutout and hole pattern for de...

Страница 14: ...nk screws must be tightened evenly and securely Observe the general mounting instructions Section 4 1 5 2 MOUNTING ACCORDING TO DEGREE OF PROTECTION IP 65 An additional mounting kit is available for m...

Страница 15: ...the connection of the Micro Panel GF0 Carry out the connection as follows The cross section of the supply cable must be between 0 75mm and 2 5mm A lead or wire can be used for the connection The powe...

Страница 16: ...rned as to how to connect the shield at the other end If no specifications are given connect the cable shield also at this end to the metal or metallised connector casing Avoid leaving the shield open...

Страница 17: ...d braid by approx 3 cm 3 Turn back the braid over the cable sheath 4 Use a heat shrinkable tubing or rubber grommet to cover the exposed cable sheath with the folded back shield braid so that 5 to 8 m...

Страница 18: ...O design software for information on the connection and operation of a printer printer installation The programming port is a standard RS232 interface The GND terminal is located directly on the housi...

Страница 19: ...is used to load the runtime program This runtime program GRSW contains the function for loading project data and so this program must be loaded before the loading of project data is at all possible Pr...

Страница 20: ...es not find an integral runtime program the Micro Panel GF0 switches to the SERIAL DOWNLOAD system mask In this mode the Micro Panel GF0 will try to establish a connection to the PC via the programmin...

Страница 21: ...o establish a connection to the PC via the programming port PROG PORT The design software GALILEO can then be used to load project data and or to reload the runtime program System mask for serial data...

Страница 22: ...information concerning currently available communications cards and communication protocols Safety precautions concerning electrostatic discharge ESD must be observed when handling cards Never plug i...

Страница 23: ...evice 11 2 MEMORY EXPANSION The Micro Panel GF0 is provided as standard with a fixed memory of 4MByte A memory expansion socket is also provided for the device concerned Section 17 Only one memory exp...

Страница 24: ...PROGRAMMING PORT PROG PORT Pin 9 of the PROG PORT can also be used for the power supply 5V of external additional hardware jumper J7 on the main board set to position A This is not short circuit proof...

Страница 25: ...ransparent plastic frame or the failure of an optical element If this LED is lit clean the plastic frame on the device front Section 13 3 RUN ACTUATE The LED green remains unlit when the system voltag...

Страница 26: ...a retentive memory If the signal of one or several channels is below a minimum level relative to the initial values this will be indicated by an error message on the screen and the DEF DIRTY LED Secti...

Страница 27: ...l determine the lifespan of the screen Reducing the brightness can significantly increase the lifespan of the LCD display Frequent switching especially at low temperatures will reduce the lifespan The...

Страница 28: ...ouch screen operation Section 13 3 Repairs to the Micro Panel GF0 must only be carried out by the manufacturer or Micro Innovation repair centres Contact in this case your local Micro Panel dealer or...

Страница 29: ...of properly or returned to the manufacturer for disposal manufacturer address for Micro Panel GF0 see last page Special note The clock module contains a sealed lithium battery Real Time Clock Dallas...

Страница 30: ...saver GF0 57SQD 20 000 POH GF0 10xVD 25 000 POH Operation MDS TCL2 Optical light matrix in the infrared range IR Touch Section 13 Resolution physical GF0 57xQD GF0 10xVD 24 x 16 13 x 15 Pixel 40 x 30...

Страница 31: ...upply Rated voltage SELV 24 VDC Safety extra low voltage Section 6 Voltage range 24 VDC to DIN 19240 20 4 28 8 VDC effective absolute value with ripple 18 5 30 2 VDC 35 0 VDC for 100ms Voltage dips 5...

Страница 32: ...romagnetic compatibility 89 336 EEC and electrical safety Low Voltage Directive 73 23 EEC The generic standards below were used to assess the electromagnetic compatibility of the Micro Panel GF0 EN 50...

Страница 33: ...L File E208621 Representative sampels of the Micro Panel GF0 have been evaluated by Underwriters Laboratories Incorporation and meet the applicable United States and Canadian safety standards To asses...

Страница 34: ...0 MICRO PANEL Revision History 34 Technical subject to change M000235 01 DOC by Micro Innovation 20 REVISION HISTORY Index Date Visum Alteration 01 12 11 03 RA Included in DokV efesotomasyon com Klock...

Страница 35: ...MICRO PANEL Device description GF0 Revision History Technical subject to change M000235 01 DOC by Micro Innovation 35 efesotomasyon com Klockner Moeller inverter...

Страница 36: ...ect to change M000235 01 DOC by Micro Innovation Micro Innovation AG Spinnereistr 8 14 CH 9008 St Gallen Switzerland Tel 41 71 243 24 24 Fax 41 71 243 24 90 email info microinnovation com homepage htt...

Отзывы: