Page 25
Installation
optoNCDT ILR 1183
The wiring diagram for utilization of switching outputs is as follows:
A
B
Pin 2
Pin 4
A
B
Pin 2
Pin 4
Profibus OUT
Profibus IN
GND
U
v
violet
red
supply
application
blue
switch output 1
gray/pink
switch output 2
Fig. 11 Wiring of switching outputs
5.7
Trigger Input
Characteristics of the input:
- Signal level HIGH > 11 V
- Signal level LOW < 6.5 V
- Input current 2.5 mA at 24 V
- Trigger edge and delay selectable
- Trigger pulse of max. 24 V
Parameter settings for the trigger input can be made using Profibus tools. This function is only enabled with
the Profibus in active state. The trigger input allows a distance measurement cycle to be triggered by an
external signal that is applied as a voltage pulse. Available setting options are the delay time (Trigger Delay)
until measurement actually starts and the pulse edge to be selected for triggering (Trigger Level). Trigger
mode (0 ... Off, 1 ... On) must be turned on. Parameter settings for Trigger Input can be made with the help of
the Profibus Master, using the Encoder profile and Class 2 encoder functionality.