background image

Page 43

Appendix| Software

MSC7401 Miniature sensor controller for inductive sensors

A 3.2.1 

Basic View

Fig. 32 Detail view Disconnect

  Click the 

Reset Y-Scale

  button to reset the Y-Scale to initials settings (e.g. after zooming).

  Click the 

Jump to Head 

button to display the current signal course. 

A 3.2.2 

Data Acquisition Start / Stop

  Start the data acquisition by clicking the 

Start

 button, see 

Fig. 33

.

The recording is completely restarted and the previously stopped recording is lost.

  Stop the data acquisition by clicking the 

Stop

 button, see 

Fig. 34

.

Fig. 33 Start

Fig. 34 Stop

Содержание MSC7401

Страница 1: ...Operating Instructions MSC7401...

Страница 2: ...MESSTECHNIK GmbH Co KG Koenigbacher Strasse 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 e mail info micro epsilon de www micro epsilon com Miniature sensor controller for indu...

Страница 3: ...2 Design 9 2 3 Technical Data 9 3 Delivery 11 3 1 Unpacking Included in Delivery 11 3 2 Storage 11 4 Installation and Assembly 12 4 1 Precautions 12 4 2 Controller 12 4 3 Power Supply Sensor and Signa...

Страница 4: ...xample D Adjustment via 2 point Adjustment 34 6 Service Repair 35 7 Liability for Material Defects 35 8 Decommissioning Disposal 35 Appendix A 1 Accessories 36 A 2 Factory Settings 37 A 3 Software 38...

Страница 5: ...damage if not avoided Indicates a user action i Indicates a tip for users Measure Indicates hardware or a software button menu 1 2 Warnings Connect the power supply and the display output device accor...

Страница 6: ...K GmbH Co KG K nigbacher Stra e 15 94496 Ortenburg Germany The measuring system is designed for use in industrial environments and meets the requirements 1 4 Intended Use The MSC7401 measuring system...

Страница 7: ...for inductive sensors 1 5 Proper Environment Operating temperature 40 to 85 C 40 to 185 F Humidity 5 95 no condensation Ambient pressure Atmospheric pressure Protection class IP 67 Storage temperature...

Страница 8: ...ee Chap 5 The demodulator electronics transforms the signal of the two secondary coils into the set output signal With the setting possibilities for zero point and gain see Chap 5 the user can adapt t...

Страница 9: ...chnical Data Model MSC7401 Supply voltage 5 V 1 14 V 30 V Current consumption 20 mA 40 mA with current output Supply protection Reverse polarity and overvoltage protection Sensors Full bridge sensor L...

Страница 10: ...Shock DIN EN 60068 2 27 40 g 6 ms 1000 per axis DIN EN 60068 2 27 100 g 6 ms 3 per axis FSO Full Scale Output 1 With technical restrictions on output signal load and signal span UB 5 V No voltage outp...

Страница 11: ...the packaging and ensure that the goods are forwarded in such a way that no damage can occur Check the delivery for completeness and shipping damage immediately after unpacking If there is damage or...

Страница 12: ...he equipment is started i Pay attention to careful handling during installation and operation 4 2 Controller Fasten the controller of series MSC7401 by means of two screws M4 The position of the mount...

Страница 13: ...2 47 76 2 99 Mounting holes for M4 screws Sensor connection Cable gland WS15 Clamping range 1 mm 5 mm Alternative option 010 M9 5 pole socket Series 712 Binder Power and signal connection Cable gland...

Страница 14: ...sensors signal output are on the controller see Fig 2 Connections Power supply output side Cable gland WS19 clamping range 4 5 mm 10 mm Connection screw terminals AWG 16 up to AWG 24 up to AWG 28 wit...

Страница 15: ...imary coil Primary coil Shield sensor cable Fig 5 Pin assignment for sensor on the terminal block X2 full bridge Terminal block X2 Coil Cable 1 DTA x CA x DTA x CR xC701 x Wire 1 DTA x LA x Solder pin...

Страница 16: ...Z20 x Connector LDR x SA Sensor cable 1 C7210 x Secondary coil Pin 3 Secondary white 1 brown Secondary coil Pin 4 brown 3 blue Center tap Pin 2 green 4 black Primary coil Pin 6 Primary Primary coil Pi...

Страница 17: ...for power supply and signal Terminal block X2 Sensor connection Terminal block X3 Digital interface RS485 Terminal block X1 Power supply and signal Pin Description Description Description 1 Housing Sh...

Страница 18: ...d signal connector M12x1 5 pole A coded 4 3 2 Sensor If the plunger is moved into the sensor this results in an increase of the output voltage if the plunger is pulled out further this results in a de...

Страница 19: ...et the controller and the sensor connected warm up for approx 2 minutes when the power supply is switched on before you perform any measurement or setting i Observe the operating instructions of the s...

Страница 20: ...4 3 2 Ensure that the wiring of the sensor connections signal cable and power supply connections are correct before connecting the controller to the power supply and turning it on see Chap 4 Then swit...

Страница 21: ...ay Channel The LED Channel indicates the current channel with and the channel can be changed red and green Channel 1 green channel 2 red Flashes in corresponding color if channel is not parameterized...

Страница 22: ...gs It is divided into four function blocks see Fig 15 The 4 LEDs show the cur rent position in the menu and the corresponding setting value at any time see Chap 5 4 Alternatively the software SensorTo...

Страница 23: ...atus D3 D4 green Sensor recognition successful After successful recognition the sensor is ready for use The output signal is preset according to the fac tory setting rough adjustment of the measuring...

Страница 24: ...on the used sensor model After manual setting of the sensor parameters the adjustment of the system is recommended see Chap 5 3 4 Sensor model Measuring range Sensor type Frequency Amplitude DTA 1x 1...

Страница 25: ...ints within the measuring range and the corresponding signal values Factory settings The controller can be reset to the parameters stored by default see Chap A 2 Zero point search This is a special ca...

Страница 26: ...nsors 5 4 Menu Structure Legend menu structure 1 O LED orange O LED orange flashing G LED green G LED green flashing R LED red R LED red flashing LED off SMR Start of measuring range MR Midrange EMR E...

Страница 27: ...zero point search see Fig 22 page 29 ENTER E1 level G Factory settings O Zero point search MENU 3 sec Automatic sensor recognition ENTER G Successful G Successful E1 level R R Failed R Failed Sensor p...

Страница 28: ...page 26 D1 Channel D2 E1 D3 E2 D4 Value Next menu G R Sensor parameter ENTER R Sensor type G DTA LVDT R LDR ENTER G Frequency DTA LDR G 1 kHz 9 kHz O 2 kHz 13 kHz R 5 kHz 16 kHz R 10 kHz 21 kHz ENTER...

Страница 29: ...t position O Flashes orange when the measu ring object is in the electrical center of the sensor ENTER G R LED color changes depending on the target position O Move the measuring object to the positio...

Страница 30: ...asuring object to the position X0 until the output reaches U0 Lights orange when the measuring object is in the electrical center of the sensor ENTER G O LED color changes depending on the target posi...

Страница 31: ...kip example A G R R R Output situation sensor is not automatically recognized Press the button twice G R Menu point Sensor parameter see Chap 5 3 3 ENTER Confirm by pressing the ENTER button G R R G S...

Страница 32: ...see Chap 5 3 2 in delivery state the electronics works with automatic load recognition depending on the output load the LED D4 is red 4 20 mA or orange 2 10 V If the automatic settings suits you you c...

Страница 33: ...e the arrow buttons to set the voltage in such a way that the measuring device displays 6 00 V U0 ENTER Confirm by pressing the ENTER button G G O Now move the measuring object to the zero point X0 MM...

Страница 34: ...4 is green or switched off G G Go to the menu Adjustment see Chap 5 3 4 ENTER Confirm by pressing the ENTER button G G G G G R Select 2 point adjustment ENTER Confirm by pressing the ENTER button G G...

Страница 35: ...replaced free of charge if the device is returned to MICRO EPSILON with shipping costs prepaid Any damage that is caused by improper handling the use of force or by repairs or modifications by third p...

Страница 36: ...ut cable length 6 m 4 wire one side tinned Strands AD 5 6 mm PC5 5 Power and output cable con nector M12x1 5 pin A coding length 5 m 5 core open ends AD 5 6 mm IP 67 IF 7001 Single channel USB RS485 c...

Страница 37: ...2 Factory Settings The controller is assigned with the following parameters by default Automatic recognition of customer signals Automatic sensor recognition Upon successful recognition Start of measu...

Страница 38: ...er software A 3 1 Search Sensor Finder Connect the controller to a free USB port on your PC e g via IF7001 and connect the power supply In the drop down menu set the sensor groups induSENSOR Sensortyp...

Страница 39: ...e channels found are now listed in the overview Choose the desired language by clicking on the respective flag icon Fig 26 Language German Fig 27 Language English Click the Configure Serial Interface...

Страница 40: ...for inductive sensors The following window is displayed Fig 29 Window Change Serial Configuration SensorTool i Tip Set the baud rate to 256 000 Baud Start the data acquisition configuration by clickin...

Страница 41: ...Page 41 Appendix Software MSC7401 Miniature sensor controller for inductive sensors The following window is displayed Fig 30 View Sensorfinder...

Страница 42: ...pendix Software MSC7401 Miniature sensor controller for inductive sensors A 3 2 Measurement To check your measurements a simple depiction of your data acquisition is available see Fig 31 Fig 31 View M...

Страница 43: ...e to initials settings e g after zooming Click the Jump to Head button to display the current signal course A 3 2 2 Data Acquisition Start Stop Start the data acquisition by clicking the Start button...

Страница 44: ...can be set in milliseconds 1 Trigger Disabled Deactivated basic settings Continuous Manual trigger One shot sample based Sample can be set records the signal course accord ing to the set samples the...

Страница 45: ...V output Click this button to start acquiring the measurement data Click this button to stop recording Click this button to save the currently selected measurement value Click this button to cancel th...

Страница 46: ...l curves of the sensors used Color Change the color settings of the single signal courses Mastering When the Master tab is activated in the menu Data acquisition Signal process ing see Fig 35 you can...

Страница 47: ...Page 47 Appendix Software MSC7401 Miniature sensor controller for inductive sensors A 3 3 Settings A 3 3 1 General Fig 39 View Settings General...

Страница 48: ...atic sensor recognition Model setting User specific sensor setting Sensor Recognition After switching on the electronics automatically identifies the sensor After successful recognition the sensor mod...

Страница 49: ...u see Fig 41 Fig 40 View Settings Output Fig 41 Section Settings Analog output Analog Output Output Range Automatic 0 0 V 10 0 V 2 0 V 10 0 V 0 0 V 5 0 V 0 5 V 4 5 V 4 0 mA 20 0 mA 0 0 mA 20 0 mA 0 0...

Страница 50: ...oint A 3 3 3 1 Two Point Fig 42 View 1 Two Point Adjustment Please make sure before the adjustment that the basic settings were carried out sensor configuration output signal and that the target can b...

Страница 51: ...Page 51 Appendix Software MSC7401 Miniature sensor controller for inductive sensors Fig 43 View 2 Two Point Adjustment Repeat this process for the second position X2...

Страница 52: ...djustment i Optionally you can enter the associated millimeter values which can be found under Measurement and the designation Custom The chart is divided into 3 areas Green Taught in range limited by...

Страница 53: ...before the adjustment that the basic settings were carried out sensor configuration output signal and that the target can be positioned accordingly Start the sensor adjustment via the start Start butt...

Страница 54: ...1 Miniature sensor controller for inductive sensors Fig 46 View 2 Zero Point adjustment Now move the target inside the midrange to the point X2 Also enter the desired output value there and accept it...

Страница 55: ...now symmetrically arranged around the zero point i Optionally you can enter the associated millimeter values which can be found under Data acquisi tion and the designation Custom The chart is divided...

Страница 56: ...provides the current overview of the controller information sensor information diagnostic infor mation and the currently connected sensor By clicking the Disconnect button you return to the sensor se...

Страница 57: ...n restore the factory settings Fig 50 Button Factory Reset Clicking Export Settings opens the explorer and enables you to save the setting values in a default csv file on the PC Fig 51 Button Export S...

Страница 58: ...N MESSTECHNIK GmbH Co KG K nigbacher Str 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 info micro epsilon de www micro epsilon com X9751377 A021118HDR X9751377 A02 MICRO EPSILON...

Отзывы: