Ethernet connection, standard link to the PC
RJ45 connector
8-pin. connector
The pin
numbers
refer to the
gapCON-
TROL 27xx
unit.
Micro-Ep-
silon
recom-
mends
using the
Ethernet
connection
cable
SC2700-5/
ET from
the recom-
mended
accesso-
ries.
Pin no.
Color stranded
hook-up wire
Pin no.
10BaseT,
100BaseTX
1000BaseT
1
white (orange)
5
Tx+
D1+
2
orange
6
Tx-
D1-
3
white (green)
8
Rx+
D2+
4
blue
1
D3+
5
white (blue)
2
D3-
6
green
7
Rx-
D2-
7
white (brown)
3
D4+
8
brown
4
D4-
1
View: pin side male cable
connector
1
2
8
3
7 6
5
4
View on solder pin side, ODU
- The sensors are supported by an automatically, sensor adapted IP address in the
link-local-net (169.254.x.x). There is no collision testing effected.
This is the standard setting.
- The sensor supports the DHCP protocol. This setting is activated by default and
has priority over the retrieval in the link-local-net.
- A fixed IP address can be used.
Use the „Ethernet Configurator“ software provided on the CD in order to make
the sensor settings described above.
8.
First Profile
Now start the gapCONTROL Setup Software. Click on “Display Profiles“ in the
main window.
If the software shows the
error message “No gap-
CONTROL found” in the
status line, please check the
Ethernet connection between
gapCONTROL and PC.
On the left side you can
adjust the settings for your
measurement task, the right
side shows the profile data
and information about the
measurement.