Safety

optoCONTROL EDU190

The supply voltage must not exceed the specified limits.

 

> Damage to or destruction of digital display

No sharp or heavy objects should be allowed to affect the cables. Avoid folding the cables. Do not bend 
more tightly than the minimum bending radius of the cables.

 

> Damage to or destruction of the cables, failure of the digital display

Avoid shocks and impacts to the digital display.
> Damage to or destruction of the digital display
Storing the digital display where the temperature is lower/higher than recommended in the technical data can 
cause the LCD display liquid to congeal/become isotopic.

 

> Damage to or destruction of digital display

Avoid use in direct sunlight, strong magnetic fields, high temperatures and sudden temperature changes.

 

> Color alterations on the display or system failure

1.3 

Notes on CE Marking

The following apply to the optoCONTROL EDU190:

 - EU Directive 2014/30/EU
 - EU Directive 2011/65/EU

Products which carry the CE mark satisfy the requirements of the EU directives cited and the European 
harmonized standards (EN) listed therein. The EU Declaration of Conformity is available to the responsible 
authorities according to EU Directive, article 10, at: 

MICRO-EPSILON Eltrotec GmbH 
GmbH & Co. KG 
Heinkelstraße 2 
73066 Uhingen /Germany

The measuring system is designed for use in industrial environments and meets the requirements.

Содержание EDU190-4 Pro

Страница 1: ...ltrotec GmbH Heinkelstra e 2 73066 Uhingen Germany Tel 49 0 7161 98872 300 Fax 49 0 7161 98872 303 eltrotec micro epsilon de www micro epsilon com EDU190 4 Pro EDU190 7 Pro Operating Instructions opto...

Страница 2: ...MICRO EPSILON Eltrotec GmbH Heinkelstra e 2 73066 Uhingen Germany Tel 49 0 7161 98872 300 Fax 49 0 7161 98872 303 eltrotec micro epsilon de www micro epsilon com Digital Display...

Страница 3: ...elivery 11 3 2 Storage 11 4 Installation and Assembly 12 4 1 Pin Assignment 14 4 2 Cables 15 4 3 Connections for optoCONTROL ODC1202 ODC1220 16 4 4 Connections for optoCONTROL ODC2600 ODC2500 17 4 5 C...

Страница 4: ...ROL EDU190 Appendix A 1 Accessories 29 A 1 1 Connecting the Digital Display to ODC1202 ODC1220 29 A 1 2 Connecting the Digital Display to ODC2500 ODC2600 29 A 1 3 Connecting the Digital Display to ODC...

Страница 5: ...es a tip for users Measure Indicates hardware or a software button menu 1 2 Warnings Avoid use in Ex areas Death or injury due to explosion hazard Liquids metal swarf and wire parts may not enter the...

Страница 6: ...isplay liquid to congeal become isotopic Damage to or destruction of digital display Avoid use in direct sunlight strong magnetic fields high temperatures and sudden temperature changes Color alterati...

Страница 7: ...pecified in the technical data see 2 2 The system must be used in such a way that no persons are endangered or machines and other material goods are damaged in the event of malfunction or total failur...

Страница 8: ...e performed on semi automated workstations quickly and easily while visualizing and evaluating the measured value without requiring any additional end devices The digital display is compatible with al...

Страница 9: ...of digits max 5 digits Baud rate 115 2 kBd Screen operation resistive touch Display 1 x multicolor LED display Serial interface RS232 or RS422 Digital interface Ethernet RJ45 socket Supply voltage 18...

Страница 10: ...ptoCONTROL EDU190 Model EDU190 4 Pro EDU190 7 Pro Material Display polyester on glass ITO film Housing rear powder coated aluminum Frame material Autoflex EBA 180L Installation front panel installatio...

Страница 11: ...he measuring system from the packaging and ensure that the goods are forwarded in such a way that no damage can occur Check the delivery for completeness and shipping damage immediately after unpackin...

Страница 12: ...cut out Secure the digital display by screwing the recesses head screw clockwise allowing the built in bracket to flip out and tighten against the cabinet Tighten the screws from 0 5 to 1 0 Nm 4 or 8...

Страница 13: ...94 100 3 94 Cut out dimensions for the installation of the digital display 130 x 89 mm 5 12 x 3 50 inches Cut out dimensions for the installation of the digital display 189 x 128 mm 7 44 x 5 04 inche...

Страница 14: ...422 RS232 Item Connection Description 1 Power supply 24 VDC 18 32 VDC 2 LAN A 1 x 10 100 Base T RJ 45 shielded 3 COM RS422 or RS232 Fig 4 Ports on the display bottom side Please refer to the operating...

Страница 15: ...29011205 RS422 9 pin 15 pin SubD IF2008 power Power no fur ther signals ODC2500 SCD2500 3 3 RS232 2901121 RS232 9 pin 25 pin SubD open braids Other signals ODC2600 ODC2500 SCD2500 3 EDU190 RS422 2901...

Страница 16: ...es 712 SPS female connector 4 pin connector Binder series 707 PC female connector 3 pin connector Binder series 712 connection to sender Power supply COM connection RS422 RS232 SCD1202 x RS232 PC190 2...

Страница 17: ...ction COM connection RS422 RS232 Light source 5 pin Operating voltage 3 pin Receiver 12 pin Inputs and outputs 25 pin SCD2500 3 EDU190 RS422 SCD2500 3 EDU190 RS232 SCD2500 3 3 RS232 PC190 2 PS2020 Por...

Страница 18: ...ottom side Ports on the controller for ODC 2520 Fig 8 Connections for optoCONTROL ODC2520 The Ethernet connection requires the SCD2520 3 and PC190 2 cables see A 1 The Ethernet version blue lines requ...

Страница 19: ...ay indicates if the transmission is active Flashing when the digital display is connected with the sensor No flashing when the digital display is not connected with the sen sor The ON OFF status is di...

Страница 20: ...P address of the EDU190 please contact the MICRO EPSILON Eltrotec GmbH support see 7 i When using the RS232 RS422 serial interface the standard baud rate of the respective optoCONTROL ODC must be used...

Страница 21: ...g the additional function for circumference calculation Defining limit and master values Monitoring the connection status Depending on the sensor a large number of additional settings such as filters...

Страница 22: ...view The settings view is displayed via the Config button see Fig 10 1 Master value settings 2 Settings IP address 3 Language setting 4 Circumference calculation from diameter measurement 5 Activating...

Страница 23: ...the Set default IP address button confirms the desired IP address With an active serial con nection the network address settings are not displayed To set a new IP address for the sensor click in the N...

Страница 24: ...highlighted in green NOK Outside of these limits this window the measured value is highlighted in red Warn limit Limit 1 Switches when the warning value WV is exceeded measured value is highlighted i...

Страница 25: ...3 Buttons for info window Info and for settings window Config 4 Green LED for connection signal flushes when connection is active 5 Selected measuring program see Fig 11 6 Triggering switched on 7 Di...

Страница 26: ...er axis of an outer diameter or width of a metal sheet first light dark and last dark light edge Arbitrary segments Differences positions and numbering or order of the edges Fig 11 Different measuring...

Страница 27: ...e 27 optoCONTROL EDU190 5 2 3 Sensor Information 1 2 3 Fig 12 View sensor information 1 Selected measuring program 2 Info about selected sensor type connection type RS422 or Ethernet 3 Trigger mode st...

Страница 28: ...ain unaffected In particular MICRO EPSILON Eltrotec shall not be liable for any consequential special indirect or incidental damage In the interest of further development MICRO EPSILON reserves the ri...

Страница 29: ...500 3 EDU190 RS232 Digital output cable 3 m long for connection via RS232 2901121 SCD2500 3 3 RS232 Signal output cable 3 m long for connection via RS232 and other signals 29011209 PC190 2 Supply cabl...

Страница 30: ...ILON Eltrotec GmbH Heinkelstra e 2 73066 Uhingen Germany Tel 49 0 7161 98872 300 Fax 49 0 7161 98872 303 eltrotec micro epsilon de www micro epsilon com X9751398 A011108HDR X9751398 A01 MICRO EPSILON...

Отзывы: