Programming the Controller with the Function Keys
CSP2008
Press the button to change to Setup No.
2
. Confirm the
selection with the button .
Setup No.
-?- Select
OK
1
-> 2 <-
3
Press the button .
The controller changes back to the menu Load/save setting
Press ESC key to exit from the submenu.
Load/save settings
Setup No. 2
Activate
Save setup
Help
B. Definition of the control input “zero” for initiating the mastering
Press the button to change to
Digital inputs 2008.
Confirm the selection with the button .
Settings
Digital CSP2008 inputs
EtherCAT-Devices
Data recording
Calculation
Data output
Press the button to change to
Active Zero
. Confirm
the selection with the button .
The zero input reacts to the High level in the factory settings.
Now change the active level.
Digital CSP2008 inputs
Mode Sync/Trig Digi In
Active Sync/Trig HIGH
Active zeroing HIGH
ZeroDuration/ms 5
ResetDuration/ms 10000
Press the button to change to
LOW
.
Confirm the selection with the button twice.
Afterwards, the controller returns to the previous menu level.
Active
-?- Select
OK
HIGH
-> LOW <-
Now define the pulse length for the mastering and ending the
mastering.
Press the button to change to
ZeroDuration/ms
. Con-
firm the selection with the button . Select the position to
be edited with the button.
Press the button once to increase the time to 60 ms.
ZeroDuration/ms
-?- Edit
OK
+
0
0050
ZeroDuration/ms
-?- Edit
OK
+000
6
0
Confirm the input with the button several times until the
controller changes to the
Digital CSP inputs
menu.
The pulse length for the ending the mastering
(ResetDura-
tion/ms)
should be 3 s.
Repeat the steps above to define the pulse length to
30000 ms for ending the mastering (
ResetDuration/ms
).
Press the ESC key; the controller changes to the main
menu.
Digital CSP2008 inputs
Active zeroing LOW
ZeroDuration/ms 60
ResetDuration/ms 10000
Set zero
Reset