Seite 28
Installation and Assembly
capaNCDT 61xx/IP
4.5
Ground Connection, Grounding
Make sure you have a sufficient grounding of the measuring object, for example connect it with the sensor
or the supply ground.
4.6
Power Supply, Display/Output Device, Sensor Connection
Pin
Color SCAC3/6/IP
Signal
Description
6
3
2
View on solder
pin side,
6-pin. female
connector
1
white
+24 V
+24 V power supply
2
grey
GND
Supply ground
3
pink
RS485_A
1
RS485 interface
4
green
AGND
Analog ground (for signal output)
5
brown
U-out
Voltage output (R min 10 kOhm)
I-out
2
Current output (max. 500 Ohm load)
6
blue
RS485_B
1
RS485 interface
Shield
Cable shield, housing
SCAC3/6/IP is a 3 m long, pre-assembled power supply and output cable.
1) Digital interface with DT6120/IP/U or DT6120/IP/I only
2) Voltage or current output
POWER/SIGNAL
SENSOR
Fig. 20 Connection power supply
and signal output
Fig. 21 Connection sensor cable