Appendix | Factory Settings
thermoMETER CSmicro
OUT
At 3-state output the following settings are default:
Pre-alarm difference
2 °C
No alarm level
8 V
Pre-alarm level
5 V
Alarm level
0 V
Service voltage
10 V
IN/OUT
At Alarm output (open collector) the following settings are default:
Mode
Normally closed
Temp code output
Activated (for values above alarm level)
Range settings
0 °C = 0 %/ 100 °C = 100 %
Vcc adjust
If activated the following settings are default:
Output voltage range
0 - 10 V
Difference mode
Activated
Alarm level
Alarm value (IN/ OUT pin)
Vcc
1
40 °C
11 V
2
45 °C
12 V
3
50 °C
13 V
4
55 °C
14 V
5
60 °C
15 V
6
65 °C
16 V
7
70 °C
17 V
8
75 °C
18 V
9
80 °C
19 V
10
85 °C
20 V
Содержание 2W-SF15H
Страница 6: ...thermoMETER CSmicro ...
Страница 21: ...Page 21 Optical Charts thermoMETER CSmicro SF15 2W 2W SF15H HS with CF lens 0 8 mm 10 mm 2W SF22H D S 22 1 ...
Страница 22: ...Page 22 Optical Charts thermoMETER CSmicro 2W SF22H with CF lens 0 6 mm 10 mm SF02 D S 2 1 ...
Страница 23: ...Page 23 Optical Charts thermoMETER CSmicro SF02 with CF lens 2 5 mm 23 mm M 2SF40 SF D S 40 1 ...
Страница 24: ...Page 24 Optical Charts thermoMETER CSmicro M 2SF40 CF D S 40 1 D S Far field 12 1 M SF75 SF D S 75 1 ...
Страница 27: ...Page 27 Optical Charts thermoMETER CSmicro M 3H SF D S 33 1 M 3H CF D S 33 1 D S Far field 11 1 ...
Страница 71: ......