TROUBLESHOOTING CHART
CAUTION:
BEFORE DISASSEMBLING THE UNIT OR DOING ANY
INSPECTION OF THE PARTS, MAKE CERTAIN THAT THE POWER HAS BEEN
CUT OFF, AND THE BLOWER HAS COME TO A COMPLETE STOP.
NEVER
RUN THE UNIT WITH THE ACCESS DOOR OPENED OR REMOVED.
PROBLEM
POSSIBLE CAUSE
REMEDY
Unit Fails to Start
Dead Power Line
Check Circuit and Switch
Blown Fuse
Replace Fuse
Loose Wire in Terminal Box
Reconnect Wire
Burned Out Motor
Replace Motor
Unit Runs Slowly or Inadequate
Wired for Wrong Voltage
Check Input Voltage
or Improper Rotation
Check Wiring Diagram
Dirty Filters
Replace Filters
(See Changing Filters Section.)
Obstruction in Hose/Arm Assembly
Reach into Hood and Remove
Obstruction
Mist Coming from Exhaust
Dirty Disposable Filters
Replace Filters
or Torn Filters
Air Bypass Around Filters
Add Foam Seal to Seal Gaps
Vibration
Loose Mounting Bolts
Tighten Bolts
Foreign Object in Blower
Remove Access Door and
Remove Object
Dirty Disposable Filters
Replace Filters
(See Maintenance Section.)
Obstruction in Hose/Arm Assembly
Reach into Hood and Remove
Obstruction