4.2 Test 

Point 

Definition 

 
The KSZ9031MNX-EVAL board has 12 usable test points, as defined in the following table. 
 

Test Point 

Definition 

TP1 

XI Clock Input (KSZ9031MNX pin 61) 

TP2 

CLK125_NDO Clock Output (KSZ9031MNX pin 56) 

TP3 

Interrupt Signal (KSZ9031MNX pin 53) with 4.7K external pull-up 

TP4 

AVDDL voltage – KSZ9031MNX power pins 

TP5 

AVDDL_PLL voltage – KSZ9031MNX power pin 

TP6 

DVDDL voltage – KSZ9031MNX power pins 

TP7 

DVDDH voltage – KSZ9031MNX power pins 

TP8 

AVDDH voltage – KSZ9031MNX power pins 

TP9 Signal 

Ground 

TP10 Signal 

Ground 

TP11 Signal 

Ground 

TP12 Signal 

Ground 

 

Table 3.  KSZ9031MNX-EVAL Board – Test Point Definition 

 
 

4.3  RJ-45 Copper Interface 

 
The RJ-45 copper interface (RJ1) connects to standard unshielded twisted pair (UTP) CAT-5 
Ethernet cable to interface with 10Base-T/100Base-TX/1000Base-T network devices. 
 
The KSZ9031MNX copper media interface can automatically detect and correct for differential 
pair misplacements and polarity reversals, and correct propagation delays and re-sync timing 
between the four differential pairs, as specified in the IEEE 802.3 standard for 1000Base-T 
operation. 

Auto MDI/MDI-X is supported for automatic detection and correction for straight and crossover 
cables when interfacing to link partners with fixed MDI or MDI-X setting. 
 

4.4 LED 

Indicators 

 
The KSZ9031MNX device provides two programmable LED output pins, LED2 (pin 17) and LED1 
(pin 19). On the KSZ9031MNX-EVAL board, these two LED pins are connected to two sets of 
LEDs to support two LED configurations:  Single LED mode and Tri-color Dual LED mode. 

 

4.4.1 

Single LED Mode 

 
To enable Single LED mode,  

 

Close pins (1, 2) of jumpers JP7 and JP8 to select D2 and D3, respectively for the single 
LEDs. 

 

Close pins (1, 2) of jumper JP9 to set the LED_MODE strap-in for Single LED mode. 

 

Power-up the board. 

 

Содержание KSZ9031MNX

Страница 1: ...for its use Micrel reserves the right to change circuitry and specifications at any time without notification to the customer Micrel Products are not designed or authorized for use as components in life support appliances devices or systems where malfunction of a product can reasonably be expected to result in personal injury Life support devices or systems are devices or systems that a are intend...

Страница 2: ...KSZ9031MNX EVAL Board User s Guide Micrel Inc August 17 2012 Rev 1 0 2 23 Revision History Revision Date Summary of Changes 1 0 8 17 12 Initial Release ...

Страница 3: ... Single LED Mode 10 4 4 2 Tri color Dual LED Mode 11 4 5 Gigabit Media Independent Interface GMII 12 4 6 Media Independent Interface MII 12 4 7 USB Port 13 5 0 Micrel MdioConfig Software Installation 14 5 1 MicrelSwitchPhyQATools Installation 14 5 2 USB Driver Installation 16 6 0 MicrelMdioConfig Software Application Programs 20 6 1 Windows Command Prompt Command Line program 20 6 1 1 Running the ...

Страница 4: ...MNX EVAL Board MII Interface Connection with Spirent SmartBits 12 List of Tables Table 1 KSZ9031MNX EVAL Board Jumper Definition 8 Table 2 Strapping Pin Definitions for KSZ9031MNX EVAL Board Jumpers 9 Table 3 KSZ9031MNX EVAL Board Test Point Definition 10 Table 4 Single LED Mode LED Definition 11 Table 5 Tri color Dual LED Mode LED Definition 11 Table 6 MII Port J1 MII Pin Definition 13 ...

Страница 5: ...SZ9031MNX EVAL provides a comprehensive platform to evaluate the KSZ9031MNX features All KSZ9031MNX configuration pins are accessible either by jumpers test points or interface connectors 2 0 Board Features Micrel KSZ9031MNX 10Base T 100Base TX 1000Base T Physical Layer Transceiver RJ 45 Jack for Ethernet cable interface Auto MDI MDI X for automatic detection and correction for straight through an...

Страница 6: ...nual reset button for quick reboot after re configuration of strapping pins GMII receive output clock and signals can be looped back to GMII transmit input clock and signals to provide a standalone platform to evaluate the KSZ9031MNX device in 1000Mbps mode MII Port J1 provides the 10 100 MAC interface connections to Micrel KSZ88xx 3 port Switch evaluation boards with the mating MII MAC interface ...

Страница 7: ...e pins 1 2 Set PHYAD2 1 JP11 PHYAD2 Close pins 2 3 Set PHYAD2 0 Close pins 1 2 Set PHYAD1 1 JP12 PHYAD1 Close pins 2 3 Set PHYAD1 0 Close pins 1 2 Set PHYAD0 1 JP13 PHYAD0 Close pins 2 3 Set PHYAD0 0 Close pins 1 2 Enable 125 MHz Clock Output JP10 CLK125_EN Close pins 2 3 Disable 125 MHz Clock Output Close pins 1 2 Select Single LED Mode JP9 LED_MODE Close pins 2 3 Select Tri color Dual LED Mode K...

Страница 8: ... 2 Select GMII RXD3 signal for GMII Loop Back JP24 TXD3 Close pins 2 3 Select MII TXD3 signal to MII Port J1 Close pins 1 2 Select GMII RXD2 signal for GMII Loop Back JP25 TXD2 Close pins 2 3 Select MII TXD2 signal to MII Port J1 Close pins 1 2 Select GMII RXD1 signal for GMII Loop Back JP26 TXD1 Close pins 2 3 Select MII TXD1 signal to MII Port J1 Close pins 1 2 Select GMII RXD0 signal for GMII L...

Страница 9: ... 17 19 PHYAD2 PHYAD1 PHYAD0 The PHY Address is latched at power up reset and is configurable to any value from 0 to 7 PHY Address bits 4 3 are always set to 00 PHYAD 2 0 001 is set as the default for the board JP10 45 CLK125_EN CLK125_EN is latched at power up reset and is defined as follows Pull up 1 Enable 125MHz Clock Output Pull down 0 Disable 125MHz Clock Output Pin 56 CLK125_NDO provides the...

Страница 10: ...interface with 10Base T 100Base TX 1000Base T network devices The KSZ9031MNX copper media interface can automatically detect and correct for differential pair misplacements and polarity reversals and correct propagation delays and re sync timing between the four differential pairs as specified in the IEEE 802 3 standard for 1000Base T operation Auto MDI MDI X is supported for automatic detection a...

Страница 11: ...l LED mode Close pins 2 3 of jumpers JP7 and JP8 to select D4 for the tri color dual LED Close pins 2 3 of jumper JP9 to set the LED_MODE strap in for Tri color Dual LED mode Power up the board After board power up the on board D4 LED is defined as follows LED D4 Link Activity OFF Link off Green ON 1000Mbps Link No Activity Green Blinking 1000Mbps Link Activity RX TX Red ON 100Mbps Link No Activit...

Страница 12: ...GMII Loop Back 4 6 Media Independent Interface MII The KSZ9031MNX EVAL Board provides access to the MII clocks and signals at the MII Port J1 Pins 2 and 3 of jumpers JP14 JP27 are closed to connect the MII clocks and signals from the KSZ9031MNX device to the MII Port J1 Similarly pins 1 and 2 of jumpers JP6 JP5 are closed to connect the MII Management pins MDC MDIO from the KSZ9031MNX device to th...

Страница 13: ...nector The following table lists the pin outs for the MII Port J1 Pin Signal Pin Signal 1 VCC NC 21 VCC NC 2 MDIO 22 Ground 3 MDC 23 Ground 4 RXD3 24 Ground 5 RXD2 25 Ground 6 RXD1 26 Ground 7 RXD0 27 Ground 8 RX_DV 28 Ground 9 RX_CLK 29 Ground 10 RX_ER 30 Ground 11 TX_ER 31 Ground 12 TX_CLK 32 Ground 13 TX_EN 33 Ground 14 TXD0 34 Ground 15 TXD1 35 Ground 16 TXD2 36 Ground 17 TXD3 37 Ground 18 COL...

Страница 14: ... Windows Installer installation package file msi file with the following file name MicrelSwitchPhyQATools_x xx msi where x xx is the release version number 5 1 MicrelSwitchPhyQATools Installation Before running the MicrelSwitchPhyQATools installation make sure previously installed version of the MicrelSwitchPhyQATools software has been removed and the USB cable to the KSZ9031MNX EVAL board is unpl...

Страница 15: ...stallation Folder screen a Select the folder for the software installation c Micrel QATools is the default installation folder b Press the Next button 3 At the Confirm Installation screen a Press the Next button for the installation to proceed b Wait a few seconds for the installation to finish ...

Страница 16: ...iver Installation Before installing the USB driver complete the MicrelSwitchPhyQATools software installation in the previous section to extract the USB driver from the MicrelSwitchPhyQATools_x xx msi installation file and have it copied to the created installation folder Power up the KSZ9031MNX EVAL Board and connect USB cable from board to PC NOTEBOOK with the Windows XP or 7 Operating System to ...

Страница 17: ...e choose your search and installation options screen a Select Include this location in the search b Press the Browse button and navigate to and select the USB driver directory C Micrel QATools D2XXDriver CDM 2 02 04 WHQL Certified is the USB driver directory for the default installation folder c Press the Next button for the USB driver installation to proceed d Wait for the USB driver installation...

Страница 18: ...ompleting the Found New Hardware Wizard screen press the Finish button to close the wizard and exit 5 After the USB driver installation verify the USB driver is installed a Go to the Windows XP System Properties box select the System icon under Windows Start Menu Settings Control Panel ...

Страница 19: ... User s Guide Micrel Inc August 17 2012 Rev 1 0 19 23 b Press the Device Manager button c Scroll down to the end of Universal Serial Bus controllers to verify USB Serial Converter A and USB Serial Converter B are installed ...

Страница 20: ... program 6 1 Windows Command Prompt Command Line program The mdioConfig exe program is a command line interface program 6 1 1 Running the program The mdioConfig exe program is executed from a Windows Command Prompt Open a Windows Command Prompt select the Command Prompt under Windows Start Menu Programs Accessories and go to the mdioConfig exe program directory c Micrel QATools is the program dire...

Страница 21: ...e Prompt 6 1 2 Read Write access to KSZ9031MNX PHY registers Direct register read and direct register write can be used to check and or update individual PHY register setting as needed The following are the commands and parameters Direct Register Read r register address hex r 0 Read PHY register 0h r 1 Read PHY register 1h r 2 Read PHY register 2h r 3 Read PHY register 3h Direct Register Write w r...

Страница 22: ...tion script file The script file can then be run to program a set of PHY registers The script file format is as follow Lines starting with the symbol are ignored and can be used to provide comments Empty lines with just the ENTER key are ignored Each command line for register read or register write is entered on a separate line and followed by the ENTER key For example the following is the content...

Страница 23: ...ev 1 0 23 23 Copy the script file into the software installation folder created earlier in section 5 0 c Micrel QATools is the default installation folder Type the following script file command line and press the ENTER key to execute the script file run sample txt ...

Отзывы: