![Micom RM125 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/micom/rm125/rm125_owners-manual_1784795005.webp)
Performance Specifications
Main Technical Characteristics
This section presents the main technical characteristics of the RM125 and RM125R. For a listing of
the additional performance specifications, refer to the “Owner’s Guide, MICOM-3E/3T/3R HF-SSB
Transceivers”, Publication 6886867J01, and to the applicable MICOM-3 Supplements that cover the
optional features available on your radio set.
Models
RM125
M91AMN0KV5-K with G638
RM125R
M95AMN0KV5-K with G638
General
Number of channels
200
Transmission frequency range
1.6 to 30 MHz
Transmit power (PEP and average)
User-selectable levels
•
Max:
125W
•
High:
100W
•
Medium: 62.5W
•
Low:
25W
Reception frequency range
100 kHz to 30 MHz
Sensitivity (SINAD)
0.3
µ
V for 10 dB SINAD
Audio bandwidth
350 to 2700 Hz
Data bandwidth
300 to 3300 Hz
Frequency stability
0.6 ppm (0.1 ppm optional)
Frequency resolution
10 Hz
Number of accessories connectors
Operating voltage
•
110 /220 VAC, 50/60 Hz, with automatic
switching
•
13.8 VDC nominal from external battery
or DC power source
Power requirements
•
Maximum 28 A from DC source
•
Maximum 500W from AC source
(without charging)
External battery
Lead-gel or lead-acid, 13.8 VDC, max. 45Ah
Operating temperature range
-10
°
C to +60
°
C/14
°
F to +140
°
F
Humidity
Up to 95% relative humidity @ 50
°
C/122
°
F
Dimensions
6888882V02
5