![Micom RM125 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/micom/rm125/rm125_owners-manual_1784795023.webp)
Load mismatch
•
Full transmit power for VSWR up to
1.5:1
•
Reduced transmit power for higher
VSWR (50% down at VSWR of 4:1)
•
Full protection against short/open circuit
Overheating protection
•
Reduced transmit power for high
temperature
•
Bypass in case of excessive temperature
Operating voltage
45 to 48 VDC from PS unit
Power requirements
•
Maximum 2000W in SSB mode
•
Maximum 3500W in CW mode
Cooling
Forced air cooling
Dimensions
Height
221 mm/8.7 inch
Width
482 mm/19 inch
Depth
492 mm/19.4 inch
Weight
25 kg/55 lbs
Output voltage
45 VDC nominal
Operating voltage
110 /220 VAC, 50/60 Hz, with automatic
switching
PS Unit Main
Characteristics
(see YM-02-670B
manual for full
information)
AC power requirements
Maximum 5000W
Cooling
Forced air cooling
6888882V02
23