OPERATING PROCEDURES
Plug the Aqua Dri into a standard grounded outlet with correct voltage and amperage. Turn on the switch and
check that the unit operates properly before leaving it unattended.
Do not carry or move the Aqua Dri when it
is running.
Auxiliary Outlet
The “daisy chain” outlet allows for the connecting of up to 3 EDIC Aqua-Dri 3007ADN machines to maximize
drying efficiency and circuit breaker usage. The red circuit breaker switch is installed in order to protect the
machine. This circuit breaker turns off the unit when more than 9 amps are run through the on-unit circuit.
MAINTENANCE
1.
Disconnect the power cord from the outlet before performing this maintenance procedure.
2.
Inspect the electrical cord and wiring for damage or discoloration.
3.
Inspect for loose fasteners.
4.
Clean screens on the sides and front of the unit.
5.
Listen for abnormal sounds.
6.
Always keep the machine clean inside and out.
7.
Motor does not require lubrication.
PERIODIC MAINTENANCE
Use compressed air or a vacuum to remove lint, etc., from the motor, screen or blower. Do not wet the motor
or the wiring. Do not use a pressure washer to clean the unit.
TROUBLE SHOOTING
PROBLEM
PROBLEM CAUSE
ELECTRICAL SYSTEM
Does not turn on
1.
Defective power cord.
2.
House or building circuit breaker tripped.
3.
Switch is defective.
4.
Capacitor is defective.
Does not operate at all
speeds
1.
Switch is defective.
2.
Capacitor is defective.
Blower wheel rubs
1.
Wheel is out of round.
Unit makes abnormal
sounds
1.
Defective motor.
2.
Foreign object stuck.