background image

TAKING INTO USE

1. Charge the lamp before using it.

 

Batteries self-discharge during storage and must be charged prior to taking the lamp into use. 

Please note that the lamp will not offer its full operating time until it has been charged and discharged ca. 

5 – 10 times

2. Mount the quick charger stand MICA MLC

Choose a suitable installation location and mount the MLC charging stand with two screws. The stand may 

not be placed on a platform manufactured of a highly flammable material or installed inside the explosive 

hazardous area.

Connect the power supply wiring (use either a constant 12-24V DC voltage power supply like a vehicle 

battery or a MICA IL-2 AC/DC adapter) in the charging stand’s round quick coupling. Alternatively, you can 

connect the power supply wires in the screw terminals on the back 

of the stand (be sure to connect the plus and the minus poles 

correctly and finally tighten the cable clamp; the plus wire (+) is 

marked in red). Please see the diagram! 

The red L1 light will light up when the power supply is connected, at the same time the L2 and L3 lights will 

flash.

Supply voltage of the charging stand must be continuous and it may not be disconnected by using a timer or 

any similar device.

A = Operating Switch

B = Type plate

C = High power LED

D = Belt clip

E = LED indicator for battery charge 

MICA ML-808 ATEX User manual

Note! When installing MLC into vehicles using 

24V system MICA Converter 24V/12V need to 

be inserted between vehicle battery supply and 

MLC charger(s) if MLC is used to charge ML-

808 lamps. Please contact your local retailer for 

information.

Отзывы: