ETS2228 Maintenance Manual
All right reserved
Page 18, Total 43
Figure19 Anti-reverse-insertion circuit
4 .Second-time power voltage-limiting module
The second-time power voltage-limiting module limits the second-time power voltage to 4.4V.
When the constant current charging operation is ended, the second-time power output is stabilized to
4.4V to provide power for the back-level circuit.. The feedback loop is accomplished by operational
amplifier 1 of TL494.