background image

 

Mianyang Weibo Electronics Co.,Limited 

No.98 Youxian East Road, Youxian District, Mianyang City, P.R. China 

Tel: 86-0816-2971265 Fax: 86-016-2281934 

www.mywbdz.com      [email protected]

 

6

6

 

 

(3)

 

Warming up the transducer for 3 minutes 

(4)

 

Using  output  monitoring  meter  V1  to  measuring  the  output  of  signal  power 
source instrument, set any input value which is within the measuring range of 
the transducer Ir. (e.g. if input value is 5A, the output is 4-20Ma, the expected 
output value Iz should be calculated as:   

Iz = (20mA-4mA)×Ir/5A+4mA )

 

(5)

 

Using output monitoring meter V2 to measuring the output voltage V0 of the 
transducer, the basic introduced error

γ

of the transducer should be calculated 

as: 

                               

γ= (Vo-Iz×250Ω)/[(20mA-4mA)×250Ω]×100 

(6)

 

  Repeating (4) (5), if calculated absolute value is less than the given accuracy 
value of the transducer, it shows the transducer’s accurate grade is qualified. 

 

Caution: 
 

1.

 

Pay attention to the auxiliary power information, especially the auxiliary power grade, 

and polarity, other wise will damage the product.     

2.

 

Pay  attention  to  the  wire  connection;  wrong  terminal  connection  will  cause 

malfunction of the product and even damage the product; 

3.

 

Don’t  dismantle  the  product,  and  carry  with  care  to  avoiding  bump  and  fall  of  the 
product; 

4.

 

If  the  product  has  been  using  under  the  environment  with  strong  magnetic  field 
interference, please pay attention to the shield of input wire, and the output signal wire 
should  be  as  short  as  possible.  For  product  intensive  installation,  the  space  between 
each product should not be smaller than 10mm. 

5.

 

Only use identified terminals.   

6.

 

There is no lightening strike prevention circuit design in this product. For out door and 
hazardous environment using, please add protective alternatives.   

7.

 

This product uses fire prevent ABS crust, its temperature withstand is only limited as 
+85

, higher than this limitation will cause the product deformation. Please use and 

store carefully. 

 

Warranty:   

 

(a)

 

Product  Warranty:  Seller  warrants  that  upon  Delivery  the  Product  to  be  supplied  by 
Weibo  shall  be  completely  new  and  shall  comply  in  all  respects  with  the  Technical 
Specification confirmed with Buyer. 

Содержание WBV417U01

Страница 1: ...ducer RMS www mywbdz com alex827 qq com Technical Service 86 816 2778271 Quality Complain 86 816 2278273 Fax Line 86 816 2281934 ISO9001 ISO14000 ISO18000 Certified Quality Warranty Any quality problem found in WB series products we offer Three years free charge of repair the products and six months guaranteed free charge of change and return the products ...

Страница 2: ...maintenance and servicing The operating manual for the equipment gives instructions for its installation commissioning and operation However the manual cannot cover all conceivable circumstances or include detailed information on all topics In the event of questions or specific problem do not take any action without proper authorization Contact the appropriate WB technical sales office and request...

Страница 3: ...Fax 86 016 2281934 www mywbdz com alex827 qq com 3 3 The product has certain advantages of total galvanic isolation between input output high accuracy low drifting by temperature and wide temperature bearable range etc Function realization schematic drawing Product Dimensional Drawing unit mm In 3 1 12 11 Out 10 11 E G _ _ ...

Страница 4: ...ent Ux 10V Ri Ux 1kΩ V Measurement Ux 10V Ri Ux 10kΩ V 7 Linear Range 0 120 of nominal input 8 Responding Time 300mS 9 Over Load Capacity 2 times of nominal input continuous 10 Maximum Load 6V 11 static current 25mA 12 Auxiliary Power 24V dc 13 Isolation Voltage 2500Vdc for 1 minute 14 Output Ripple 40mV root mean square value output load is 250Ohm 15 Drifting by Temperature 5 10 3 16 Ambient Temp...

Страница 5: ...ately But for further precise signal sampling user needs to warm up the product for 3 minutes before use a The auxiliary power requires isolation voltage 2000VAC DC current output ripple 10mV and multiple converters can share with one set auxiliary power together b Output signal Iz is designed to follow the impedance load value of 250Ω When Resistance R1 is less than 100Ω the user must add output ...

Страница 6: ...and polarity other wise will damage the product 2 Pay attention to the wire connection wrong terminal connection will cause malfunction of the product and even damage the product 3 Don t dismantle the product and carry with care to avoiding bump and fall of the product 4 If the product has been using under the environment with strong magnetic field interference please pay attention to the shield o...

Страница 7: ...year warranty of free charge of repairing the product and any purchase made in six months Weibo will provide free charge of change and return the product if damage and problem caused by product quality Note Transportation fee of repaired and returned product will be borne by Buyer Product Input Output characteristic curve Input 0 100 4mA 20mA Input Output characteristic curve 20 23 2 120 Output mA...

Отзывы: