background image

 

3

Product Description and Application   

WBV415S01 converts AC input voltage into a load independent output signal RMS 0~5V. It has 
adopted electromagnetic isolation principle and RSM measurement method for real time 
measurement of AC voltage (in any wave form) from electric net or electric circuit. 

 

The product has certain advantages of total galvanic isolation between input and output, high 
accuracy, low drifting by temperature, and wide temperature bearable range, etc.       
 

Function realization schematic drawing 

 

In 

6

Mianyang Weibo Electronics Co.,Limited 

No.7 Road 2 of Xianren Road Youxian District Mianyang City P.R. China     

Tel: 86-816-2971265 Fax: 86-816-2281934 

www.wb-my.com

3

 
 
 
 
 

 

Product Dimensional Drawing (unit: mm)   

 

               
 
 
 

GN

Out 

+E GND

_

     

[email protected]

 

Содержание WBV415S01

Страница 1: ...ucer TRUE RMS www wb my com wblch wbdz cn Technical Service 86 816 2778271 Quality Complain 86 816 2278273 Fax Line 86 816 2281934 ISO9001 ISO14000 ISO18000 Certified Quality Warranty Any quality problem found in WB series products we offer Three years free charge of repair the products and six months guaranteed free charge of change and return the products ...

Страница 2: ... The operating manual for the equipment gives instructions for its installation commissioning and operation However the manual cannot cover all conceivable circumstances or include detailed information on all topics In the event of questions or specific problem do not take any action without proper authorization Contact the appropriate WB technical sales office and request the necessary informatio...

Страница 3: ...t or electric circuit The product has certain advantages of total galvanic isolation between input and output high accuracy low drifting by temperature and wide temperature bearable range etc Function realization schematic drawing In 4 6 5 3 Mianyang Weibo Electronics Co Limited No 7 Road 2 of Xianren Road Youxian District Mianyang City P R China Tel 86 816 2971265 Fax 86 816 2281934 www wb my com...

Страница 4: ...nput 9 Responding Time 300mS 10 Over Load Capacity 2 times of nominal input continuous 11 Maximum Load 5mA 12 Static Current 20mA 13 Auxiliary Power 12VDC or 24VDC optional 14 Isolation Voltage 2500Vdc for 1 minute 15 Output Ripple 40mV root mean square value output load is 250Ohm 16 Drifting by Temperature 200 10 6 17 Case Protection and Material IP20 Flame Retarded ABS Conform to UL94V 0 18 Mean...

Страница 5: ... 10mV and multiple converters can share with one set auxiliary power together 3 Basic testing method for accuracy 1 According to the terminal definition table to connect the testing circuit 2 The testing must to be done by under the following conditions Auxiliary power 24V 1 ripple 5mV Ambient temperature 25 2 Relative humidity RH 45 75 Accuracy for Signal Power Source instrument 0 05 Signal Power...

Страница 6: ...p and fall of the product 4 If the product has been using under the environment with strong magnetic field interference please pay attention to the shield of input wire and the output signal wire should be as short as possible For product intensive installation the space between each product should not be smaller than 10mm 5 Only use identified terminals 6 There is no lightening strike prevention ...