Designing, Manufacturing and Supplying WB Series Electric Isolated Transducer and 

Digital Electrical Transducer since 1989 

 
 
 

USER MANUAL 

WBI417S41 TRUE RMS SENSING 

AC current transducer 

 

 

 

 
 
 

 

www.weiboelectronic.cn

[email protected]

 

  Tel: 86 0816 2971265 

  Fax: 86 0816 2281934 

ISO9001/ ISO14000/ ISO18000 /Certified Company 

 

 

Содержание WBI417S41

Страница 1: ...ectric Isolated Transducer and Digital Electrical Transducer since 1989 USER MANUAL WBI417S41 TRUE RMS SENSING AC current transducer www weiboelectronic cn wbwm wbdz cn Tel 86 0816 2971265 Fax 86 0816 2281934 ISO9001 ISO14000 ISO18000 Certified Company ...

Страница 2: ...and safe operation of the equipment depends on appropriate shipping and handling proper storage installation and commissioning and on careful operation maintenance and servicing The operating manual for the equipment gives instructions for its installation commissioning and operation However the manual cannot cover all conceivable circumstances or include detailed information on all topics In the ...

Страница 3: ...as certain advantages of total galvanic isolation between input output high accuracy low drifting by temperature and wide temperature bearable range etc Product Dimensional Drawing unit mm Aperture Size 4 mm Product Terminal Identification Drawing Input I 9 Auxiliary Power Output Ground GND Auxiliary Power E 1 3 4 Output Iz Non identified terminal cannot be used Mianyang Weibo Electronics Co Limit...

Страница 4: ...4mV root mean square value output load is 250Ohm 13 Drifting by Temperature 200 10 6 14 Ambient Temperature Commercial grade 0 50 Industrial grade 25 70 15 Mounting DIN Rail 35mm Mounting or screw mounting Instruction of Installation and Use 1 The product has adopted structure compliance with EN50022 suitable for DIN rail mounting NS35 7 5 NS35 15 Installation steps are as following please referen...

Страница 5: ...ollowing conditions Auxiliary power 24V 5 ripple 5mV Ambient temperature 25 5 Relative humidity RH 45 75 Accuracy for Signal Power Source instrument 0 05 Signal Source Transducer Power Supply 250Ohm 3 1 V1 R 3 6 V2 3 Warming up the transducer for 3 minutes 4 using output monitoring meter V1 to measuring the output of signal power source instrument set a any input value which is within the measurin...

Страница 6: ...ention to the wire connection wrong terminal connection will cause malfunction of the product and even damage the product 3 Don t dismantle the product and carry with care to avoiding bump and fall of the product 4 If the product has been using under the environment with strong magnetic field interference please pay attention to the shield of input wire and the output signal wire should be as shor...