background image

 

 

Mianyang Weibo Electronic Co.,Limited 

No.98 Youxian East Road, Youxian District, Mianyang City, P.R. China 

Tel: 86-0816-2971265 Fax: 86-016-2281934 
www.weibo-sensor.com      [email protected]

 

the signal source and give an arbitrary input value Ir within 
the  range  of  the  sensor.  Assuming  that  the  input 
specification  of  the  sensor  is  1A  and  the  output 
specification is 5V, the theoretical output value UZ of the 
sensor is calculated by the following formula : 
Uz = 5V×Ir/1A 

(5)

 

Use the output monitoring table V2 to measure the voltage 
output  value  U0  at  the  output  end  of  the  sensor,  and  the 
basic  reference  error  γ  of  the  sensor  is  calculated  as 
follows: 

γ

= (U0

Uz)/5V

×

100 

(6)

 

Repeating (4) (5), if calculated absolute value is less than 
the  given  accuracy  value  of  the  transducer,  it  shows  the 
transducer’s accurate grade is qualified. 

 

Caution: 
 

1.

 

Pay  attention  to  the  auxiliary  power  information,  especially  the 
auxiliary power grade,  and polarity, other wise will damage  the 
product.     

2.

 

Pay attention to the wire connection; wrong terminal connection 
will  cause  malfunction  of  the  product  and  even  damage  the 
product; 

3.

 

Don’t  dismantle  the  product,  and  carry  with  care  to  avoiding 
bump and fall of the product; 

4.

 

If the product has been using under the environment with strong 
magnetic field interference, please pay attention to the shield of 
input  wire,  and  the  output  signal  wire  should  be  as  short  as 
possible.  For  product  intensive  installation,  the  space  between 
each product should not be smaller than 10mm. 

5.

 

Only use identified terminals.   

6.

 

There  is  no  lightening  strike  prevention  circuit  design  in  this 
product. For out door and hazardous environment using, please 
add protective alternatives.   

7.

 

This  product  uses  fire  prevent  ABS  crust,  its  temperature 
withstand  is  only  limited  as  +85  ℃,  higher  than  this  limitation 
will  cause  the  product  deformation.  Please  use  and  store 
carefully. 

Содержание WBI122S01

Страница 1: ...B Series Electric Isolated Transducer and Digital Electrical Transducer since 1989 USER MANUAL WBI122S01 AC DC Current Transducer www weibo sensor com sales wbdz cn Tel 86 0816 2971265 Fax 86 0816 2281934 ISO9001 ISO14000 ISO18000 Certified ...

Страница 2: ...f the equipment depends on appropriate shipping and handling proper storage installation and commissioning and on careful operation maintenance and servicing The operating manual for the equipment gives instructions for its installation commissioning and operation However the manual cannot cover all conceivable circumstances or include detailed information on all topics In the event of questions o...

Страница 3: ...oelectric isolation principle and average value conversion technology to measure the AC and DC current in the power grid or circuit in real time and convert it to DC voltage Uz output it has many features such as universal AC DC current input high precision high isolation wide frequency response fast response time low drift low power consumption and wide temperature range This product adopts a car...

Страница 4: ...ominal input current value last for 1s with an interval of 300s repeat 5 times 8 Load capacity 5mA 9 Auxiliary power supply DC 12V 24V 10 Quiescent current 34mA 11 Isolation withstand voltage DC 1 5kV 1min 12 Output ripple 15mV effective value 13 Ambient temperature 0 50 14 Temperature drift 250 10 6 Instruction of Installation and Use 1 The product has adopted structure compliance with EN50022 su...

Страница 5: ... powered and used immediately But for further precise signal sampling user need to warm up the product for 3 minutes before use The auxiliary power requires isolation voltage 2000V AC DC current output ripple 10mV 3 Basic testing method for accuracy 1 According to the terminal definition table to connect the testing circuit 2 The testing must to be done by under the following conditions Power supp...

Страница 6: ...tention to the auxiliary power information especially the auxiliary power grade and polarity other wise will damage the product 2 Pay attention to the wire connection wrong terminal connection will cause malfunction of the product and even damage the product 3 Don t dismantle the product and carry with care to avoiding bump and fall of the product 4 If the product has been using under the environm...

Отзывы: