WOS-SERIES Operator's Manual
TroUBLESHooTinG
SyMpTOM
pROBaBlE CaUSE
REMEDy
sEPARATOR TANk
Water will not flow into the
Separator
Sump pump (4)
is not turned on.
Move
Sump pump Switch (40)
to
Tank (9)
.
"ON".
Circuit breaker has tripped or is "OFF". Reset or turn breaker "ON".
Dirt is lodged in the pit check valve.
Clean.
Sump pump (4)
impeller is clogged.
Disconnect power and clean.
lines or valves contain frozen water.
allow to thaw. Inject with warm
water if necessary.
shAfT sEAls
Water is leaking at pumps.
Damaged stationary shaft seal.
Seal ran dry. Ensure seal chamber
is filled with liquid.
Short seal life.
Unexpected temperature and
Replace.
chemical usage.
WATER flOW
air shoots from Water Outlet.
This is a common occurrence while
air will stop shooting from the water
pump is priming.
outlet when pump is primed.