Mi-T-M MH-0040-PM10 Скачать руководство пользователя страница 4

 

 

 

 

      

     Propane Patio Heater Manual

Hazard

Potential Consequence

Prevention

RISK OF EXPLOSION OR 
FIRE

Serious injury may occur if 
the heater air inlet or outlet is 
blocked.

Serious injury or death may 
occur, if heater is running while 
operating.

Serious injury may occur if 
heater is not placed on level 
surface.

Serious injury or death may oc-

cur if a flame is used to test for 

leaks. 

Serious injury could occur from 
touching exposed metal parts.  
These areas can remain hot for 
some time after the heater is 
turned off.

Always operate heater in  a well 

ventilated area free of  flammable 

vapors, combustible dust, gases 
or other combustible materials.

Do not insert or allow any foreign 
objects to enter any ventilation 
or exhaust opening as this may 

cause a fire, or damage to the 

heater.

This heater is EXTREMELY HOT 
while in operation.

Bulk fuel storage should be a 
minimum of 25 ft. from heaters, 
torches, portable generators, or 
other sources of ignition. All fuel 
storage should be in accordance 
with federal, state, or local au-
thorities having jurisdiction.

Never move or handle heater 
while still hot. 

Always locate heater on a stable 
level surface.
Always keep away from children 
and animals.

Do Not use a flame to test for 

leaks. Follow Checking for Leaks 
on page 9.

Never allow any part of your 
body or other materials to make 
contact with any exposed metal 
parts on the heater.

IMPORTANT SAFETY INSTRUCTIONS

RISK OF BURNS

WARNING: NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A 

POWER SOURCE.

Содержание MH-0040-PM10

Страница 1: ... OF INJURY READ ENTIRE MANUAL BEFORE OPERATING THIS MANUAL IS AN IMPORTANT PART OF THE HEATER AND MUST REMAIN WITH THIS UNIT Propane Patio Heaters OPERATOR S MANUAL MH 0040 PM10 Copyright 2009 Mi T M Corporation 37 1070 E F S 102114 C US 247218 ...

Страница 2: ...14 00001 10 11 OPERATION 12 LIGHTING INSTRUCTIONS 12 AFTER FIRST LIGHTING 12 WHEN HEATER IS ON 12 RELIGHTING 13 SHUT DOWN INSTRUCTIONS 13 MAINTENANCE 14 STORAGE 14 BETWEEN USES 14 DURING EXTENDED PERIODS OR WHEN TRANSPORTING 14 TROUBLESHOOTING 15 STATEMENT OF WARRANTY 16 WARNING NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Warning This product contains lead a ch...

Страница 3: ... T M Patio Heater You can be assured your Mi T M Heater was constructed with the highest level of precision and accuracy Each component has been rigor ously tested by technicians to ensure the quality endurance and performance of this heater This operator s manual was compiled for your benefit By reading and following the simple safety installa tion and operation maintenance and troubleshooting st...

Страница 4: ...sert or allow any foreign objects to enter any ventilation or exhaust opening as this may cause a fire or damage to the heater This heater is EXTREMELY HOT while in operation Bulk fuel storage should be a minimum of 25 ft from heaters torches portable generators or other sources of ignition All fuel storage should be in accordance with federal state or local au thorities having jurisdiction Never ...

Страница 5: ... CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE AN LP CYLINDER NOT CONNECTED FOR USE SHALL NOT BE STORED IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE PROPOSITION 65 WARNING FUELS USED IN GAS WOOD BURNING OR OIL FIRED APPLIANCES AND THE PRODUCTS OF COMBUSTION OF SUCH FUELS CO...

Страница 6: ...PT TO OPERATE THIS PATIO HEATER UNTIL YOU HAVE READ AND UNDERSTOOD ALL SAFETY PRECAUTIONS AND INSTRUCTIONS LISTED IN THIS MANUAL INCORRECT OPERATION OF THIS UNIT CAN CAUSE SERIOUS INJURY DO NOT ALTER OR MODIFY THIS EQUIPMENT IN ANY MANNER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ...

Страница 7: ...e 250 PSI max Manifold Pressure 11 W C Size Height 7 2 Size Diameter 32 5 16 Net Weight Lbs 59 Cylinder Required 20lb Reflector Assembly Head Assembly Post Cylinder Cover Cylinder Base FEATURES The Propane Patio Heater comes with safety features including anti tilt switch and auto shutoff switch The features of the Propane Patio Heater is shown ...

Страница 8: ...or OUTDOOR use only If stored indoors detach and leave the LP cylinder outdoors 7 Never replace the regulator with any regulator other than the factory suggested replacement 8 This heater should be secured or moved inside if winds exceed 22 miles per hour to prevent damage to heater 9 Do not insert or allow any foreign objects to enter any ventilation or exhaust opening as this may cause a fire or...

Страница 9: ...the Regulator with 3 8 open end wrench and adjustable wrench then fix it iwth the fixing chain Attach Regulator to LP cylinder Tighten securely then move LP cylinder to the plate of the Base assembly 8 Check for leaks All factory connections of your Patio Heater have been checked To check the connections of the Gas Hose Regulator LP cylinder 1 Make leak test solution by mixing 1 part liquid dish s...

Страница 10: ... 20 Bolts 4 pcs Use flange cover after tightening bolts 3 Attachheadassemblytopost LoadHeadAssemblybyinsertingGasHoseintoPost InsertHeadAssembly into Post Tighten securely using M5x12 Bolts 4 pcs 4 Attach the upper pole to the lower pole by six M4 x 8 bolts 5 Assembly of reflector Attach Reflector Cap to top of reflector 4 pcs using the M6 x 10mm Bolts 12 pcs 6mm Washers 12 pcs and M6 Nuts 12 pcs ...

Страница 11: ...mixing 1 part liquid dish soap and 3 parts water b Spoon several drops or use a squirt bottle of the solution onto the Gas Hose Regulator or the Regulator LP cylinder connection c Inspect the connections and look for bubbles d If no bubbles appear the connection is safe Do not use a flame to test for leaks e If bubbles appear then there is a leak Loosen and re tighten the connection where bubbles ...

Страница 12: ...osition b Keep depressing the control knob put a long stem lighter into the ignition hole on the emitter screen To light the burner c Repeat step 4 FLAME CHARACTERISTIC The flame pattern at the emitter screen should be visually checked whenever heater is operated Normally the burner flame is blue but little yellow flame is acceptable If flames extend beyond surface of the emitter grid or the pheno...

Страница 13: ...ob to the OFF position 2 Wait at least 5 minutes before attempting to relight 3 Repeat steps beginning with step 2 under Lighting Instructions SHUT DOWN INSTRUCTIONS 1 Push in and turn Control Knob to the OFF position 2 Turn gas valve on LP cylinder clockwise until tight to close WARNING ALWAYS BE SURE CONTROL KNOB IS OFF AND CYLINDER IS OFF WHEN LEAVING HEATER NEVER LEAVE THIS PATIO HEATER UNATTE...

Страница 14: ...mpressed air may help clear away smaller particles 6 Carbon deposits may create a fire hazard Clean dome and emitter with warm soapy water if any carbon deposits develop At least ONCE A YEAR check the section of the hose inside the post 7 In salt air environments such as near an ocean corrosion occurs more quickly than normal Frequently check for corroded areas and repair them promptly STORAGE BET...

Страница 15: ...w 2 Orifice blocked 3 Control valve is not ON 4 Thermocouple is bad 5 Pilot light assembly is bent or not in the correct location REMEDY 1 LP cylinder is near empty Refill LP cylinder 2 Remove and clean and replace if needed 3 Turn valve to ON 4 Replace thermocouple 5 Place pilot in proper position and retry ...

Страница 16: ...examine the item and determine if defective Mi T M will repair or replace and return the item freight pre paid If Mi T M finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Mi T M disclaims all warranties for prod ucts that are purchased from sellers other than authorized reta...