background image

4. Wiring Diagram

5. Attention

1. Please check whether the input voltage is in accordance with the control box working voltage, and please check the 

connection of both the cathode and anode.

2. Non-professional user cannot dismantle the control box directly, Otherwise the control box may be broken.

1. All connected lights to "SYS-PT1 control box" cannot be over 200W, otherwise, it will damage the control box.
2. The wiring method, please see details for the SYS series instructions.

Made in China

Note

1. Connecting over 50pcs lights.
2. Connected cable length over 300m.
3. Output power over 200W.

INPUT 

AC100~240V

Indicator

Light

Receiving

Antenna

Protective

Vents

1-Channel Host Control Box

Made in China

Brown: L

Blue: N

Yellow-green: 

OUTPUT 

DC24V 8.5A

Input: AC100~240V  50/60Hz

Output: DC24V  Max 8.5A(Max 200W)

Model No.: SYS-PT1

Brown: V+

Blue: V-

Yellow-green: DATA 

L N

L N

INPUT 

AC100~240V

INPUT 

AC100~240V

SYS-PT1 1-Channel Host Control Box 

(Need to buy separately)

Connect Mi-Light 

SYS series lighting

Connect Mi-Light 

SYS series lighting

Connect Mi-Light 

SYS series lighting

POWER INPUT

AC100~240V

Indicator

Light

DATA

INPUT

DATA INPUT

Protective

Vents

1-Channel Amplifier Box

Made in China

OUTPUT 

DC24V 8.5A

POWER INPUT
AC100~240V  50/60Hz

OUTPUT
DC24V  Max 8.5A(Max 200W)

Model No.: SYS-PT2

Brown: V+
Blue: V-
Yellow-green: DATA 

Brown: V+
Blue: V-
Yellow-green: DATA 

Brown: L
Blue: N
Yellow-green:

DATA
INPUT

Отзывы: