Installation & Operation Manual  

 

Before we start  

Thank you and congratulations, you are now the proud owner of one of the most environmentally friendly 
and efficient wood burning stoves available in the market today. 
Your new stove is fully compliant with all European and UK laws and meets all the criteria of EcoDesign 
2022. 

 
Please take a moment to study some of the key points that should be taken into consideration before you start 
using your new stove. 
 
At Mi-Fires we believe the best way to enjoy the maximum benefit from your new stove is that it should be 
installed by a fully trained competent stove installer that can identify the optimal way to install and 
commission your new appliance. 
You can find a list of fully approved and trained stove and chimney installers on the HETAS website or take 
advice from a registered competent person. 
WWW.HETAS.CO.UK  

  
Please Note:  

It is a 

legal 

requirement under England, Scotland, N.I. and Wales building regulations that the 

installation of the stove is carried out under local authority building control approval or installed by a 
competent person registered with a government approved scheme.  
 
MI-Fires are CE approved, Defra smoke exempt and can be used in smoke controlled zones only when the stop 
is in place and installed in accordance with the current building control regulations.  
 

Please note:

 this is a 

wood only

 stove, your new stove has been specifically designed for the combustion of 

wood and approved wood bricks. The use of other mineral fuels are not allowed. 
The appliance should not be used as an incinerator for house hold waste or any unapproved fuels. 
 
This appliance does get hot whilst running. It is recommended that a suitable guard is used to protect children 
and the elderly or infirm.  
 

Please do not make any unauthorised changes or modifications to your appliance. 
Warning: Take care, the stove surfaces reach extremely high temperatures. To minimise the effects to the 
environment a few keys rules should be remembered. 
 
Always Ensure: 
 
The Correct Stove  
The Correct Installation 
The Correct Fuel  
The Correct Operation

.  

The Correct Sweeping and Maintenance 

 
These few rules when followed will give you years of heat and enjoyment from your new stove. 
 

Production Number  

The wood stove has a production number on the rating plate on the back of the stove. We recommend that 
you note down this number in the box below before mounting the wood stove. For the purposes of the 
guarantee and for other enquiries, it is important that you are able to quote this number.

 

 

 

 

 

 

 

 

 

Содержание Grisedale

Страница 1: ...Version 1 2019 sdm Loughrigg Skiddaw Grisedale User Installation Manual BS EN 13240 2001 A2 2004 tested as intermittent appliances burning wood logs www mi fires com ...

Страница 2: ...proved Defra smoke exempt and can be used in smoke controlled zones only when the stop is in place and installed in accordance with the current building control regulations Please note this is a wood only stove your new stove has been specifically designed for the combustion of wood and approved wood bricks The use of other mineral fuels are not allowed The appliance should not be used as an incin...

Страница 3: ...nt safety information 3 2 The Stove Air Controls 3 3 How should I use my wood burning stove 3 4 Lighting a fire in the wood burning stove 3 5 Important Information for Wood Burning 4 Cleaning and Maintenance 4 1 Chimney Sweeping 4 2 Combustion chamber 4 3 Glass 4 4 Gaskets 4 5 Ash 4 6 Cleaning the stove 4 7 Spare Parts List 5 Warranty Recording 5 1 MI Fires Stoves Warranty 5 2 Installer details an...

Страница 4: ...1 Compliance 1 1 Dimensions Loughrigg Skiddaw Grisedale ...

Страница 5: ...at 13 O2 Nmg m 103 98 127 DIN Plus Particulates at 13 O2 Nmg m 18 12 14 Distance to Combustible Back mm 300 250 250 Distance to Combustible Sides mm 400 400 400 Distance to Furniture Front mm 1075 1075 1075 Minimum Hearth Distance Front mm 400 400 400 The results stated were obtained when burning wood logs 1 3 Transportation When taking your wood burning stove home please ensure that it travels in...

Страница 6: ...s Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are met 2 2 Position of the stove Distance requirements The wood burning stove must be installed in a suitable and physically possible position You need to be sure that the position complies with local regulations Please ensure if the stove is placed in a fireplace recess it is ad...

Страница 7: ...chimney draft of 10 14 Pascal Pa measured in the flue pipe above the stove However with natural draft the draft in the chimney will be between 18 25 Pa when conditions are optimum There are many factors that affect the chimney draft including the outside temperature wind strength and surrounding buildings The minimum flue height requirement is 4 5 metres if this cannot be achieved you will have to...

Страница 8: ...authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area In England ...

Страница 9: ...se wait to empty the ash until you are sure that there are no embers in the ash The door should be kept closed while the wood burning stove is in use While lighting the fire the door can stand ajar for the first few minutes In the event of a chimney fire Close all the dampers on the wood burning stove and call the fire fighting service Your installer should have fitted a CO alarm in the same room ...

Страница 10: ...wn to embers before new logs are added To obtain the best possible combustion you should regulate the effect heat output with the fuel and Air Burning small logs provides more powerful combustion than burning large logs as the surface area is greater and more gas is released The amount of wood in the combustion chamber is another factor that affects combustion The optimum combustion is achieved by...

Страница 11: ...e tertiary air inlet profiling in the rear vermiculite firebox liners at the back of the stove Always make sure that flames are visible above the wood after re fuelling for cleanest burning Burning without flames above the fuel will create unnecessary smoke After re fuelling open the primary air control fully for 3 minutes or until the logs are fully blackened to achieve full flames above the fuel...

Страница 12: ... g the Aduro Easy Clean pad The pad neither scratch nor damage the glass and is for multiple usages Water or other cleaning agents are not necessary It is common maintenance to tighten the glass fittings shortly after the stove has been installed as well as to check if the gaskets are properly placed 4 4 Gaskets With time gaskets around glass and door will wear We recommend that you inspect them r...

Страница 13: ...6 S VBP 236 M VBP 236 L VBP VERMICULITE FIRE BOX LEFT 236 S VFBL 236 M VFBL 236 L VFBL VERMICULITE FIRE BOX RIGHT 236 S VFBR 236 M VFBR 236 L VFBR VERMICULITE FIRE BOX BASE 236 S VFBB 236 M VFBB 236 L VFBB VERMICULITE FIRE BOX BACK LEFT 236 S VFBBL 236 M VFBBL 236 L VFBBL VERMICULITE FIRE BOX BACK RIGHT 236 S VFBBR 236 M VFBBR 236 L VFBBR AIR CONTROL 236 S AC 236 M AC 236 L AC HANDEL CHROME 236 HC...

Страница 14: ...s and receipts must be retained as proof of maintenance Exclusions Limitations The warranty will be void if the appliance is not installed by a suitably qualified person or is not installed in accordance with the current building regulations The warranty will be void if the appliance is modified in any way or assembled incorrectly MI Flues Ltd will not be responsible for any incidental or conseque...

Страница 15: ...nstallers Contact Details H E T A S Number Date of Installation Appliance serial number Flue Draft test completed Yes No Pascal Rating Type of Flue system diameter Unlined Masonry Lined Masonry Clay pot Insulated Twin wall system Flue system Manufacturer Installation instructions left with customer Yes No ...

Страница 16: ...5 3 Annual Service Sweeping record DATE ENGINEER SWEEP NAME CERTIFICATE RETAINED ...

Страница 17: ...is form and return it to MI Flues Ltd MI Fires Warranty Registration Taymin Business Park Mitcham Road Blackpool Lancashire FY4 4QN Your Details Name Address Postcode Contact Number Email Model Name Serial Number Installation Date Installer Name Installer H E T A S Registration No ...

Страница 18: ......

Страница 19: ......

Страница 20: ...Mi Flues Ltd Taymin Business Park Mitcham Rd Blackpool Lancashire UK FY4 4QN Tel 01253 600060 Fax 01253 600061 sales mi flues com sales mi fires com ...

Отзывы: