Mi-Fires Grisedale Скачать руководство пользователя страница 11

Warning: 

The control and handles will get warm when the wood burning stove is in use. Please use the glove 

provided when you operate the wood burning stove.

 

 

4. Once the first charge of wood has burnt away leaving a glowing bed of embers slowly open the stove door 
using the glove provided and re-stoke the fire with the desired amount of wood. Close the door and open the 
air control to maximum (towards you) for a few minutes to allow the new wood to catch fire then slowly push 
the air control back into the stove until the desired effect is reached. 
 
In order to avoid the quenching of the stove fire by use of oversized logs we recommend a maximum wood 

fuel size of 4” (10cm) diamete

r by 

10” (25cm) length 

split seasoned logs, with a maximum moisture content of 

20%.  
This appliance is designed to operate with the door closed, except for lighting and reloading, failure to close 
the door during operation can result in fume spillage. 
 

Warning: 

Properly installed, operated and maintained this appliance will not emit fumes into the dwelling.  

Occasional fumes from re-fuelling may occur. However, persistent fume emission is potentially dangerous and 
must not be tolerated. If fume emission does persist, the following immediate actions should be taken:  
Open doors and windows to ventilate room then leave the premises. Let the fire go out or eject and safely 
dispose of fuel from the appliance. Check for flue or chimney blockage, and clean if required. Do not attempt 
to relight the fire until the cause of the fume emission has been identified and corrected. If necessary seek 
expert advice 

 

3.5 Important Information for Wood Burning  

 

With a full load of wood and burning near nominal output the stove will need to be refuelled approximately 
every 1-1.5 hours. One or two large logs will burn longer than a number of smaller ones. Care must be taken 
that logs do not touch the baffle or the glass panel. Do not stack logs above the level of the tertiary air inlet 
profiling in the rear vermiculite firebox liners at the back of the stove. 
 
Always make sure that flames are visible above the wood after re-fuelling for cleanest burning. Burning 
without flames above the fuel will create unnecessary smoke. After re-fuelling open the primary air control 
fully for 3 minutes or until the logs are fully blackened to achieve full flames above the fuel.  
Wood burns best on a bed of ash and it is therefore only necessary to remove surplus ash from the stove 
occasionally. Burn only dry, well-seasoned wood, which should have been cut, split and stacked - under cover 
from rain - for at least 12-24 months with free air movement around the sides of the stack to enable it to dry 
out.  
Burning wet or unseasoned wood will create tar deposits in the stove and chimney and will not produce a 

satisfactory heat output. Wood that is not properly dry (‘dry’ is considered to be less than 20% internal 

moisture content) uses up energy from the burn process to evaporate the water inside the wood thus creating 
very poor conditions for combustion.  
The main cause of burning problems with wood stoves is due to excessively damp wood. Wood can appear 
perfectly dry on the outside but still contain 40-50% water on the inside. A moisture meter can be purchased 
from stove and equipment suppliers if you wish to check your wood source is correct. Split a log and check the 
inside as well as the outside.  
 

Refuelling on to a low fire bed 

if there is insufficient burning material in the fire bed to light a new fuel charge, 

excessive smoke emission can occur. Refuelling must be carried out onto a sufficient quantity of glowing 
embers and ash so that the new fuel charge will ignite in a reasonable period. If there are too few embers in 
the fire bed, add suitable kindling to prevent excessive smoke.  
 

Fuel overloading 

the maximum amount of fuel specified in this manual should not be exceeded, overloading 

can cause excess smoke.  
 

Operation with door left open 

Operation with the door open can cause excess smoke and spillage into the 

room. The appliance 

‘Must Not’ 

be operated with the appliance door left open. 

Содержание Grisedale

Страница 1: ...Version 1 2019 sdm Loughrigg Skiddaw Grisedale User Installation Manual BS EN 13240 2001 A2 2004 tested as intermittent appliances burning wood logs www mi fires com ...

Страница 2: ...proved Defra smoke exempt and can be used in smoke controlled zones only when the stop is in place and installed in accordance with the current building control regulations Please note this is a wood only stove your new stove has been specifically designed for the combustion of wood and approved wood bricks The use of other mineral fuels are not allowed The appliance should not be used as an incin...

Страница 3: ...nt safety information 3 2 The Stove Air Controls 3 3 How should I use my wood burning stove 3 4 Lighting a fire in the wood burning stove 3 5 Important Information for Wood Burning 4 Cleaning and Maintenance 4 1 Chimney Sweeping 4 2 Combustion chamber 4 3 Glass 4 4 Gaskets 4 5 Ash 4 6 Cleaning the stove 4 7 Spare Parts List 5 Warranty Recording 5 1 MI Fires Stoves Warranty 5 2 Installer details an...

Страница 4: ...1 Compliance 1 1 Dimensions Loughrigg Skiddaw Grisedale ...

Страница 5: ...at 13 O2 Nmg m 103 98 127 DIN Plus Particulates at 13 O2 Nmg m 18 12 14 Distance to Combustible Back mm 300 250 250 Distance to Combustible Sides mm 400 400 400 Distance to Furniture Front mm 1075 1075 1075 Minimum Hearth Distance Front mm 400 400 400 The results stated were obtained when burning wood logs 1 3 Transportation When taking your wood burning stove home please ensure that it travels in...

Страница 6: ...s Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are met 2 2 Position of the stove Distance requirements The wood burning stove must be installed in a suitable and physically possible position You need to be sure that the position complies with local regulations Please ensure if the stove is placed in a fireplace recess it is ad...

Страница 7: ...chimney draft of 10 14 Pascal Pa measured in the flue pipe above the stove However with natural draft the draft in the chimney will be between 18 25 Pa when conditions are optimum There are many factors that affect the chimney draft including the outside temperature wind strength and surrounding buildings The minimum flue height requirement is 4 5 metres if this cannot be achieved you will have to...

Страница 8: ...authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area In England ...

Страница 9: ...se wait to empty the ash until you are sure that there are no embers in the ash The door should be kept closed while the wood burning stove is in use While lighting the fire the door can stand ajar for the first few minutes In the event of a chimney fire Close all the dampers on the wood burning stove and call the fire fighting service Your installer should have fitted a CO alarm in the same room ...

Страница 10: ...wn to embers before new logs are added To obtain the best possible combustion you should regulate the effect heat output with the fuel and Air Burning small logs provides more powerful combustion than burning large logs as the surface area is greater and more gas is released The amount of wood in the combustion chamber is another factor that affects combustion The optimum combustion is achieved by...

Страница 11: ...e tertiary air inlet profiling in the rear vermiculite firebox liners at the back of the stove Always make sure that flames are visible above the wood after re fuelling for cleanest burning Burning without flames above the fuel will create unnecessary smoke After re fuelling open the primary air control fully for 3 minutes or until the logs are fully blackened to achieve full flames above the fuel...

Страница 12: ... g the Aduro Easy Clean pad The pad neither scratch nor damage the glass and is for multiple usages Water or other cleaning agents are not necessary It is common maintenance to tighten the glass fittings shortly after the stove has been installed as well as to check if the gaskets are properly placed 4 4 Gaskets With time gaskets around glass and door will wear We recommend that you inspect them r...

Страница 13: ...6 S VBP 236 M VBP 236 L VBP VERMICULITE FIRE BOX LEFT 236 S VFBL 236 M VFBL 236 L VFBL VERMICULITE FIRE BOX RIGHT 236 S VFBR 236 M VFBR 236 L VFBR VERMICULITE FIRE BOX BASE 236 S VFBB 236 M VFBB 236 L VFBB VERMICULITE FIRE BOX BACK LEFT 236 S VFBBL 236 M VFBBL 236 L VFBBL VERMICULITE FIRE BOX BACK RIGHT 236 S VFBBR 236 M VFBBR 236 L VFBBR AIR CONTROL 236 S AC 236 M AC 236 L AC HANDEL CHROME 236 HC...

Страница 14: ...s and receipts must be retained as proof of maintenance Exclusions Limitations The warranty will be void if the appliance is not installed by a suitably qualified person or is not installed in accordance with the current building regulations The warranty will be void if the appliance is modified in any way or assembled incorrectly MI Flues Ltd will not be responsible for any incidental or conseque...

Страница 15: ...nstallers Contact Details H E T A S Number Date of Installation Appliance serial number Flue Draft test completed Yes No Pascal Rating Type of Flue system diameter Unlined Masonry Lined Masonry Clay pot Insulated Twin wall system Flue system Manufacturer Installation instructions left with customer Yes No ...

Страница 16: ...5 3 Annual Service Sweeping record DATE ENGINEER SWEEP NAME CERTIFICATE RETAINED ...

Страница 17: ...is form and return it to MI Flues Ltd MI Fires Warranty Registration Taymin Business Park Mitcham Road Blackpool Lancashire FY4 4QN Your Details Name Address Postcode Contact Number Email Model Name Serial Number Installation Date Installer Name Installer H E T A S Registration No ...

Страница 18: ......

Страница 19: ......

Страница 20: ...Mi Flues Ltd Taymin Business Park Mitcham Rd Blackpool Lancashire UK FY4 4QN Tel 01253 600060 Fax 01253 600061 sales mi flues com sales mi fires com ...