28
Set end positions (set top end position for 230 V)
Note:
Should the new end position be above the currently set end position, the latter must first
be deleted. See detailed instructions at www.mhz.de
Using the
M
ove buttons
, move
the blind into the desired
position.
Press
Stop button
for 6 seconds
(Do not select a channel button
on the remote control unit)
Button light on the
transmitter flashes.
Teach-in readiness
established.
+
Press Motor button and keep
pressed.
Additionally, within 3 seconds,
briefly press
Open button
.
Blind briefly moves up and
down once.
+
Release
Motor button
.
If the buttons are still flashing,
the remote control unit is still in
‘Teach-in Readiness’ mode.
Press
Stop button
for 6 seconds
or wait for 20 seconds.
Button lighting on the
trans mitter stops flashing.
Teach-in readiness ended.
The top end position has now
been set.
To set again, repeat steps.
PowerView® I
Roller Blind Programming Guide