background image

65D1009

EYF Series Unvented Gas Log Set

CONTENTS

Important Safety Information ......................................3
Getting Started ..............................................................5
 

Codes .......................................................................7

Product Features and Specifications .........................5
General Installation Information .................................6

 

Adequate Combustion and  
Ventilation Air ...........................................................

6

Fireplace and Hearth Dimensions...............................7
Placement in a Fireplace with a Restrictive Barrier ..7
Clearances and Height Requirements ........................8
Floor Clearance ..........................................................10
Fireplace Preparation .................................................10
Installing Vented Appliance .......................................10
Gas Line Connection ..................................................12
Checking Gas Pressure .............................................12
Electrical Wiring (Millivolt) .........................................13
 

Connect Optional Remote Receiver ...................14

Log Placement ............................................................15
Flame Appearance ......................................................18
 

Pilot Flame Appearance .........................................18

 

Burner Flame Appearance .....................................19

Operating Instructions ...............................................19 

For Your Safety Read Before Lighting ...................0 
Manual Control Lighting Instructions ......................1 
Millivolt Control Lighting Instructions ...................... 
Match Lighting Instructions ....................................3

Maintenance ................................................................23
Troubleshooting .........................................................24
Replacement Parts .....................................................26
Massachusetts Requirements ...................................30
Warranty ......................................................................31

Thank you and congratulations on your purchase of a 

Gas Log Set

PLEASE READ THE INSTALLATION AND OPERATION INSTRUCTIONS BEFORE USING THE APPLIANCE!

IMPORTANT: Read all instructions and warnings carefully before starting installation. 

Failure to follow these instructions may result in a possible fire hazard and will void the warranty. 

Содержание EYF18

Страница 1: ...O IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas...

Страница 2: ...Remote Receiver 14 Log Placement 15 Flame Appearance 18 Pilot Flame Appearance 18 Burner Flame Appearance 19 Operating Instructions 19 For Your Safety Read Before Lighting 20 Manual Control Lighting I...

Страница 3: ...ceramic fiber logs proper location of the heater and annual cleaning are neces sary to avoid potential problems with sooting Sooting resulting from improper installation or operation can settle on su...

Страница 4: ...pe of gas indicated on the rating plate This ap pliance is not convertible for use with other gases 20 The heater and its individual shutoff valve must be disconnected from the gas supply piping syste...

Страница 5: ...te Max Input Min Input Model Fuel Control BTU h BTU h EYF18NM Nat Manual 30 000 18 000 EYF18PM LP Manual 30 000 22 500 EYF18NV Nat Millivolt 30 000 20 000 EYF18PV LP Millivolt 30 000 24 500 EYF24NM Na...

Страница 6: ...r less with openings gasketed or sealed b weather striping has been added on openable windows and doors and c caulking or sealants are applied to areas such as joints around window and door frames bet...

Страница 7: ...log set in a fireplace that has a restrictive barrier along the bottom front opening of the fireplace Some examples of barri ers are glass screen door frames and sunken recessed fireplaces Height of...

Страница 8: ...n To install the gas logs into a fireplace with no wooden mantel shelf or other combustible projection above the fireplace opening measure the heat resistant material height per Figure 5 then see TABL...

Страница 9: ...R extend heat resistant material to at least 12 and refer to Figure 8 Less than 8 Extend heat resistant material to at least 8 and install hood CABR CABL refer to Figure 6 OR extend heat resistant mat...

Страница 10: ...eat resistant sealant Do not seal the chimney flue damper INSTALLING VENTED APPLICATIONS Manual and millivolt controlled gas logs may be installed as a vented decorative log set in compliance withANSI...

Страница 11: ...e two 2 hooks on front of control panel Make certain front feet of grate are located inside front edge of fireplace or firebox 3 Anchor holes are located on the flange of the unit After centering the...

Страница 12: ...the heater s rat ing plate If the gas supply is different DO NOT INSTALL THE HEATER Contact your dealer for the correct model Connecting directly to an unregulated propane LPG tank can cause an explo...

Страница 13: ...Switch Millivolt Valve ODS Pilot TH 3 TP 1 TP TH 2 ODS Pilot Spade Terminal Switch Optional Wall Switch or Remote Receiver FP2112 Figure 16 Wiring Diagram Connecting Optional Wall Switch or Thermosta...

Страница 14: ...hown in chart by connecting meter test leads to terminals as indicated A Complete Millivolt System Check A Reading Thermostat contacts CLOSED Control knob ON Main burner should turn ON 1 If reading is...

Страница 15: ...with soap and water to remove any traces of fibers Install EYF24 F log unit on burner Figure 18 1 Install Main Log 1 on middle and rear supports of base Tabs should fit inside log center opening Chec...

Страница 16: ...utouts Figure 22 NOTE Logs 1 2 and 3 have ridges on the bottom which secure the logs to burner frame After installing each log check to be sure it is stable LG707 EYF18 rear log Rear Log 1 LG707 Figur...

Страница 17: ...logs to burner frame After installing each log check to be sure it is stable LG712 EYF24 rear log Rear Log 1 LG712 Figure 24 Place Rear Log LG713 EYF24 Middle log MIddle Log 2 LG713 Figure 25 Place Mi...

Страница 18: ...gures 29 30 for correct pilot flame If the pilot flame does not touch the thermocouple then the main burner cannot function reliably Refer to Figures 29 30 for incorrect shape of pilot flame Figure 29...

Страница 19: ...onents of this appliance are treated with certain oils films or bonding agents These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial opera...

Страница 20: ...ns If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to...

Страница 21: ...push and release the piezo ignitor button to light the ODS pilot The pilot is located on the left side of the heater behind the middle log and in front of the back log If piezo ignitor does not light...

Страница 22: ...th the control knob pushed in push in and release the piezo ignitor button to light the pilot 8 Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shut ti...

Страница 23: ...ent Pages 15 17 for correct log placement Periodic Cleaning Refer to the parts diagram for location of items discussed below Do not use cleaning fluid to clean logs or any part of heater Brush logs wi...

Страница 24: ...l shutoff valve closed 2 Control knob not in PILOT position 3 Control knob not pressed in while in PILOT position 4 Air in gas lines when installed 5 ODS pilot is clogged 6 Gas regulator setting is no...

Страница 25: ...d 1 Burner orifice is clogged or dam aged 2 Burner is damaged 3 Gas regulator is defective 1 Vapors from paint or curing process of logs 1 Turning control knob to HIGH posi tion when burner is cold 2...

Страница 26: ...ntrol 1 18D0603 18D0603 18D0603 18D0603 7 Control Valve 1 30D0201 30D0202 30D0201 30D0202 8 Regulator 1 24D0305 24D0306 24D0305 24D0306 Regulator to Valve Tube 1 65D1004 65D1004 65D1004 65D1004 Valve...

Страница 27: ...nt Log 1 65D1038K 65D1030K 65D1033K 65D1501K 3 Top Left Log 1 65D0008K 65D1035K 65D1035K 4 Top Right Log 1 65D0009K 65D1034K 65D1034K 5 Rear Log 1 65D1036K 65D1031K 65D1031K 6 Middle Log 1 65D1037K 65...

Страница 28: ...65D1009 28 EYF Series Unvented Gas Log Set...

Страница 29: ...29 65D1009 EYF Series Unvented Gas Log Set...

Страница 30: ...ly with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Please r...

Страница 31: ...itten warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 MHSC shall not be liable for incidental consequential special...

Страница 32: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...