![MHM SYNCHROPRINT 3000 Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/mhm/synchroprint-3000/synchroprint-3000_operating-instructions-manual_1783438044.webp)
Operating Instructions - Synchroprint 3000 (Manual-Registration Version)
________________________________________________________________________________
Operating Instructions - Synchrprint 3000 (Manual-Registration Version) V1-1
Page 44 of 49
8.
Error Messages
Possible error messages are listed as follows:
Error message
Error description
Action
ERROR CANBUS 1 - 5
Malfunction of CAN
communication to the indicated
CAN-junction.
1 … B&R - Module station 1 to 8
2 … B&R - Module station 9 to 16
3 … B&R - Module servo board
4 … Servo amplifier ACOPOS
5 … B&R - Module station 17 to 18
Check CAN-cabling. Replace the
affected component.
PROX.SWITCH TURN
-DRIVE CENTRE-
POSITION
Incorrect signal from the turntable
position sensors.
Check all three turntable position
sensors and cabling.
SWITCH CHANGE-
PALLET
Incorrect signal from the micro-
switch for the pallet release.
Check micro-switch, cabling and
function of the pallet release cylinder.
ENDPOSITION -
LIFTING CYLINDER
UP/DOWN
Signals for the lift cylinder up/down
are active at the same time.
Check both limit switches including
their cabling.
ENDPOSITION -
LIFTING CYLINDER
DOWN
No signal for lift cylinder down.
Check limit switch and cabling.
MAIN AIR-PRESSURE
TO LOW
(CYL.SWITCH UP ?)
No signal for lift cylinder up,
possibly
due
to
insufficient
compressed air supply (no separate
monitoring).
Check compressed air supply. Also
check limit switch and cabling.
REFERENCE POINT
NOT FOUND
Not possible to find the correct
reference position for the turntable.
Check all three turntable position
sensors and cabling.
ERROR SERVO
TURN-DRIVE
Error message from the servo
controller ACOPOS.
Restart the machine. Contact MHM if
this error persists.
TARGET POSITION
WRONG
The signals from the turntable
position sensors are incorrect at the
target position. (Possible defective
drive system).
Check all three turntable position
sensors and cabling. Check entire drive
system (servo amplifier ACOPOS,
servo motor, transmission, belt).
EMERGENCY STOP or
SAFETY-LINE
EMERGENCY STOP button is
pressed or safety circuit is activated.
Release EMERGENCY STOP and
close all safety barriers. Check the
safety barrier micro-switches and
cabling.
ERROR DIGITAL
ROTATIONAL
REGULATOR
SYNCHRON
Difference in the turntable position
detection
through
the
internal
resolver of the servo-motor and
external rotary encoder.
Check terminal adapter of the external
rotary encoder and/or replace external
rotary encoder.
ERROR DIGITAL
ROTATIONAL
REGULATOR
No signal from the external rotary
encoder.
Check terminal adapter and/or replace
external rotary encoder.
PROX.SWITCH
STATION No.1-18
Both sensors for squeegee stroke
length adjustment are active at the
same time. (Station No. will be
indicated)
Check the position of the sliding
adjusters for the squeegee stroke length
on the relevant print station. Check
relevant sensors and cabling, located in
the squeegee carriage block.