10.1 Accessing Controller Parameters
To access the controller parameter menu, from the standard home screen, press the OK button once then
press and hold the INFO button for 5 seconds until the lower section of the screen changes. Use the wheel
to highlight the ENGINEER setting. Press the OK button.
Access to all setting below is now possible using the rotary button.
Button
Notation
Description
Rotary
Button
Used to move through menus/lists of options.
OK
Button
Used to confirm a selection
Escape
Button
Used to escape back one level through menus
P
ar
amet
e
r #
Description
Range
Default
Ad
vis
ed
Ch
ang
e
Unit
Time And Date
1
Hours/Minutes
00:00-24:00
----
hh:mm
2
Day/Month
01.01-31.12
----
dd:mm
3
Year
2004-2099
----
yyyy
Operator Section
20
Language
English / Deutsch / Französisch /
Italienisch /Niederländisch / Spanisch /
Portugiesisch / Dänisch / Schwedisch /
Finnisch
English
22
Info
Temporarily, Permanent
Temporarily
26
Operation
On, Off
Off
27
Programming Lock
On, Off
Off
28
Direct Adjustment
Storage with Confirmation, Automatic
Storage
Storage With
Confirmation
29
Units
°C, bar / Fahrenheit, PSI
°C, bar
44
Operation HC2
Jointly with HC1, Independent
Jointly with HC1
46
Operation HC3/P
Jointly with HC1, Independently
Jointly with HC1
70
Software
----
06.7
Time Program Heating Circuit 1
500
Day/Days
Mo-Su, Mo-Fr,Sa-
Su,Mo,Tu,We,Th,Fr,Sa,Su
Mo-Su
501
1
st
Phase On
00:00-24:00
06:00
hh:mm
502
1
st
Phase Off
00:00-24:00
22:00
hh:mm
503
2
nd
Phase On
00:00-24:00
24:00
hh:mm
504
2
nd
Phase Off
00:00-24:00
24:00
hh:mm
505
3
rd
Phase On
00:00-24:00
24:00
hh:mm
506
3
rd
Phase Off
00:00-24:00
24:00
hh:mm
516
Default Values
No, Yes
No
Time Program Heating Circuit 2
520
Day/Days
Mo-Su, Mo-Fr,Sa-
Su,Mo,Tu,We,Th,Fr,Sa,Su
Mo-Su
521
1
st
Phase On
00:00-24:00
06:00
hh:mm