ASSEMBLY INSTRUCTIONS THERMOSTATIC SHOWER    CB437

1/2

FIRST STEP

Remove various parts from the carton with extreme care.

Handle Body (E) – Knob (G) – Cover (H) – CAM (F) – Ring (B)

Check on the wall that the built-in thermostatic valve is clean and that installation has been made 
correctly according to our separate pre-assembly instructions. In particular, check that the coloured 
line indicated on the plastic protection lid is posi/-10 mm with respect to the wall level (FIG 
1) and that the shower finishing plate covers wall cutting area.
At this point remove (by unscrewing) plastic protection lid from the valve body and the protective 
sleeve from output nozzle. 
IMPORTANT: make sure that the valve is closed by fully turning its plastic body clockwise

ASSEMBLY OF MAIN HANDLE WITH THERMOSTATIC CONTROL

(FIG 2)
- Place finishing plate (A) on valve body (B’) and nozzle (C’) pushing it against the wall.
- Fully screw ring (B) to body (B’) keeping patterned area on the outside which will block the ring 
  to the finishing plate.
- Fully screw tube (c) onto nozzle (c’) and the threaded part will reappear.
- Slide centring ring (D) on tube (c) until the reduced diameter disappears into the finishing plate.

(FIG 3)
Push handle (E) on the valve by keeping lever in vertical position (valve is closed).
ATTENTION: Check that the handle is fully pushed in. 

(FIG 4)
Insert cam (F) on the large broach of the valve and block to the handle with the 3 allen screws M4 
as per (FIG 4A).

(FIG 5)
- Place knob (G) on the valve’s central shaft and rotate until the 3 pins appear through the holes.
- Tighten firmly with screw M4 after positioning washer (R).
- Close by screwing cover (H) on the handle through enclosed 3 pin tool.

CHANGING WATER TEMPERATURE AT STOP POSITION

Cam (F) in default position (FIG 4A) determines with an anticlockwise rotation of the knob, a stop 
point corresponding to a  comfortable warm water temperature. To increase water temperature pull 
the patterned ring of the knob and continue anticlockwise rotation. By inverting to clockwise 
rotation the stop point will fall back into position.
To change temperature stop point, remove knob (G) (FIG 5), loosen 3 allen screws (FIG 4a) and 
change position of cam (F) (FIG 4). Rotate towards left for warmer water and towards right for 