Page 9 of 32 A10H0321-NA
SMMP
Single Speed Single Phase Motor
The arrows indicate the motor shaft rotation direction (seen from shaft end)
depending from selected wiring.
Auxiliaries devices wires identification
The below chart provides indication
about the markers applied on the
auxiliaries wires you can easily find
inside the terminals box (see an
example on the picture shown on the
side) in order to identify them. The
power supply f.e. of the heaters or of the
forced ventilation is stated on the motor
name plate. For any doubts on the
auxiliaries connection we please you to
contact us.
Device Marker
Note: The motor auxiliary devices wiring depending from motor type might
be different from what indicated in the above picture that is provided just
as an example.
The anti-condensation heaters can be powered only when the motor is
turned off. Never power the heaters while the motor is on.
Device
Wire Identification
Space Heaters
HT
Themal protectors (PTO)
TP
Thermistors (PTC)
TM
Forced Cooling
SV