![MGL Avionics V16 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/mgl-avionics/v16/v16_user-manual_1783279008.webp)
the procedures required.
No acknowledge is sent in response to these commands
26
Increase Intercom volume (3dB).
00
Don't care data value (recommend to set to zero)
Sends acknowledge when message received OK
27
Decrease intercom volume (3dB).
00
Don't care data value (recommend to set to zero)
Sends acknowledge when message received OK
28
Set Intercom volume
nn
Volume value 0-31 (lowest to highest)
Sends acknowledge when message received OK
29
Increase RX volume (3dB).
00
Don't care data value (recommend to set to zero)
Sends acknowledge when message received OK
30
Decrease RX volume (3dB).
00
Don't care data value (recommend to set to zero)
Sends acknowledge when message received OK
31
Set RX volume
nn
Volume value 0-31 (lowest to highest)
Sends acknowledge when message received OK
Format of Acknowledge message (sent by transceiver)
$02 $05 $06 $53 (full message including checksum)
Format of status message (sent by transceiver every 100mS unless setup
menu is active)
02
STX
05
DLE
04
Message type
nn
Flags
Bit 0 – 1 = TX is active
Bit 1 – 1 = Scanning is active