TC-1 Operating Manual

Page 6

Select the display mode of the TC-1. The options are:

MULT/VERT

: Multiple channels displayed simultaneously as vertical bars 

MULT/HORI

: Multiple channels displayed simultaneously as horizontal bars

SNGL/VERT

: Only a single vertical channel is displayed at a time

SNGL/HORI

: Only a single horizontal channel is displayed at a time

 TC BARS

: Vertical grouped EGT/CHT channels are shown simultaneously on one display

         NUMERICAL

: Only numerical temperature values are shown side by side

Select if you want the channel indicators/display screens to swap automatically or if you want to do it 
manually using the rotary control.

Note:

  Flipping through the different channels can still be done manually using the rotary control 

even if the display mode is set to auto. 
This menu option is only shown if “Multiple/Vertical”, “Single/Vertical”, “Single/Horizontal”, or “TC

 

        Bars” is selected as a display mode.

Set the time that each of the channels must be displayed for. This menu option is only shown if auto 
is selected for the display mode.

4.3 TC Setup

The TC-1 has 2 different “TC SETUP” menus due to the fact that the TC-1 can be setup to display the thermocouple 
temperatures in so many ways.

   

 

“MULTPLE/VERTICAL”, “MULTIPLE/HORIZONTAL”, “SINGLEL/VERTICAL”, 
“SINGLE/HORIZONTAL”, “NUMERICAL” TC Menu Setup

Move the highlight over this menu item and press the rotary button to return to the main menu

Select how many TC channels must be monitored on the TC-1

Select   whether   you   want   the   temperature   to   be   displayed   in   degrees   Celsius   (ºC)   or   degrees 
Fahrenheit (ºF)

Select which channel you want to 
setup

Содержание TC-1

Страница 1: ... Each channel also offers a programmable high alarm The TC 1 also records maximum temperatures reached for each channel in permanent memory 1 Features 6 different display modes Supports J K and E thermocouple probes Temperatures can be displayed in degrees C or degrees F from 100ºC to 1200ºC 148ºF to 2192ºF High accuracy Built in thermocouple linearization curves and cold junction compensated Reco...

Страница 2: ... in menu system Contrast adjustment in normal mode Rotary Control Up Down Enter Button Press the rotary control during normal mode to access the menu system Rotate anti clockwise for up down menu scrolling During normal mode rotating the rotary control will scroll though the different channels display mode dependant LED Alarm The red LED will illuminate if any of the temperatures monitored exceeds...

Страница 3: ...m set point Alarm set point Alarm set point Digital temperature display Maximum temperature reached indicator Analog temperature display Maximum temperature reached indicator Analog temperature display Digital temperature display Channel name Analog temperature display Channel name Digital temperature display Maximum temperature reached indicator ...

Страница 4: ... cause the TC 1 to return to the normal display mode Note The permanent maximum values are stored in non volatile memory and are recalled on power up Temperature value Channel name CHT group indicator EGT group indicator EGT Value Indicates highest value if Highest is selected or the highlighted bar value if Scanning is selected CHT alarm level Temperature display unit EGT alarm level CHT Value In...

Страница 5: ... down keys or the rotary control to navigate through the menu system 4 1 Exit Menu Pressing the rotary control on this menu item will cause the TC 1 to exit the menu system All changes made during navigation of the menu system will be saved in non volatile memory on exiting the menu system If you remove power before exiting the menu the instrument will not save any changes 4 2 Display Setup Move t...

Страница 6: ...still be done manually using the rotary control even if the display mode is set to auto This menu option is only shown if Multiple Vertical Single Vertical Single Horizontal or TC Bars is selected as a display mode Set the time that each of the channels must be displayed for This menu option is only shown if auto is selected for the display mode 4 3 TC Setup The TC 1 has 2 different TC SETUP menus...

Страница 7: ...n alarm limit Any temperature above this limit will activate the alarm Active alarms will flash the affected channel and also activate the alarm contact that you can use to switch a lamp on Select whether you want to turn the alarm on or off To avoid false activation of the alarms the alarm function is only activated 10 seconds after the instrument has powered up Select if you are using a K type J...

Страница 8: ...n the highest temperature you expect to measure using this channel Select this function to ON if you want the bar graph display to show the upper half of the temperature range only This results in a higher resolution of the temperature range you may be interested in For engine temperature measurements we recommend that you set this to ON Adjust the temperature that you would like to use as an alar...

Страница 9: ...e Temperature Range 20ºC to 80ºC 4ºF to 176ºF Humidity 85 non condensing Power Supply 8 to 30Vdc SMPS switch mode power supply with built in 33V over voltage and reverse voltage protection Current Consumption Approx 42mA 13 8V backlight on 15mA 13 8V backlight off Display 114x64 graphic LCD display Contrast and backlight is user configurable green yellow backlight ADC 12bit over sampled successive...

Страница 10: ... plastic heat shrink sleeving it does not last Choose probes that use a generous amount of stainless steel spring as strain relief The bolt itself should be stainless steel as well or it will rust very quickly CHT Probes These are made from washers to fit spark plug bases Temperatures are considerably lower so most thermocouple cables will work without problems The biggest area of concern should b...

Страница 11: ...l 1A fuse is recommended Connect the supply terminals to your aircrafts power supply The TC 1 can be used on both 12V and 24V without the use of any pre regulators Ensure that the supply voltage will not drop below 8V during operation as this may result in incorrect readings ...

Страница 12: ...TC 1 Operating Manual Page 12 9 2 Connection diagram for a Rotax 503 582 ...

Страница 13: ... open air installations this will be the case Should this not be possible or you require best possible accuracy at all times you can obtain a special K type extension cable This cable is made from the same metals as your probes cable and uses ordinary plastic sleeving as insulation In either case ensure that the cable is not routed close to sources of electromagnetic interference of any kind The v...

Страница 14: ...placement of faulty components and includes the cost of labour Shipping costs are for the account of the purchaser DB 9 Pin Color Function 1 Black Ground 4 NC Airtalk communication Not connected Used for firmware upgrading 6 Red 8 30Vdc power 9 White Alarm Output DB 9 Pin Color Function 1 Blue TC Channel 1 2 Orange TC Channel 2 3 Green TC Channel 3 4 Purple TC Channel 4 5 Black Reference ground co...

Страница 15: ... failure or malfunction Under no circumstances does the manufacturer condone usage of this instrument for IFR flights Other instruments in the Stratomaster Infinity series ALT 1 Precision encoding altimeter and vertical speed indicator ALT 2 Precision encoding altimeter and vertical speed indicator with a serial RS232 transponder output ASI 1 Airspeed indicator ASI with automatic flight log ASX 1 ...

Отзывы: