background image

 

   

Operating and instruction manual 

 

NOTE

:  If the motor does not start immediately, it is possible that the air receiver is already full of air. 

The motor will start automatically once the cut-in pressure is reached.

 

 

3. 

Connect one end of the correct air hose to the connector at the air outlet (D, Fig. 2) and 

the other end to the nozzle/accessory being used

4. 

Set  the  outlet  pressure  with  the  pressure  regulator  (B,  Fig.  2)  by  turning  it  clockwise  to 

increase  pressure  and  anti-clockwise  to decrease  pressure.  Check  the  pressure  reached  on 
the manometer (C, Fig. 2). 

NOTE

:    Max  pressure  allowed  is  50  psi  (6  bar)  unless  otherwise  indicated  by  the  manufacturer’s 

instructions. However, you may need to set the operating pressure at a higher or lower level for other 
airline equipment (e.g. tyre gauges, staple guns, paraffin guns etc.). 

5. 

The pressure switch placed inside the silent cover should not require adjustment. This is 

an automatic device and has been preset at the factory to stop the motor when pressure in the 
receiver reaches its maximum, and to start it again when the pressure in the receiver falls to 
the  minimum  preset  value.  This  operation  is  completely  automatic  and  does  not  affect  the 
compressing  process.  However,  should  problems  develop  with  the  cut-in,  cut-out  settings, 
please consult your MGF dealer. 

NOTES

:   

a.  If the machine pumps continuously without cutting out then the compressor is too small 

for the application/tool being used, and damage may result. Consult your MGF dealer. 

b.  The motor is protected by a Thermal Overload which will trip and stop the motor should 

it overheat for any reason. Let the motor cool down for 15 – 20 min before restarting. 

c.  Do not exceed the Duty Cycle for the machine

for a best performance do not exceed 

the 50% of duty cycle (50% of duty cycle: for ex. 50sec ON – 50 sec OFF) 

SHUTTING DOWN THE COMPRESSOR

 

1.  Turn the ON/OFF switch (A, see Fig. 2) to the ‘OFF’ position to switch the compressor off. 
2.  Release air from the air hose and pipe before disconnecting the hose from the machine by 

releasing the air from the connected pipe. 

3.  Make sure all air is expelled from the receiver before transporting your compressor or leaving 

overnight.

IMPORTANT: 

DO NOT switch the compressor ON or OFF by the mains. ALWAYS switch the 

compressor ON or OFF by the pressure switch ONLY.

MAINTENANCE

 

EVERY 6 MONTHS 

 

Check, clean and, in case, replace the aspiration filter inside the cover following the instructions 
below: 
 

1.  Unscrew N° 2 screw as shown on picture 3.  

 

 

FIG. 3 

 

 
 

Содержание S-OF050

Страница 1: ...truction manual OILLESS PISTON COMPRESSOR Tel 39 02 9019180 www mgfcompressors com MGF S r l Via Pascoli 15 20081 Abbiategrasso MI ITALY Fax 39 02 9019273 Tel 39 02 9019253 680 e mail info mgfcompressors it Beverage compressor ...

Страница 2: ...aulty manufacture for a period of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned without prior permission This guarantee does n...

Страница 3: ...on Wait for compressor to cool down 12 For safe operation adjust the pressure regulator to the recommended setting as indicated by the specific tool or accessory being used for a particular usage and application 13 Not spray near any flames or areas where sparks or other sources of ignition may occur 14 Make sure that the area is well ventilated when using materials that give off fumes or sprays 1...

Страница 4: ...is completely automatic and does not affect the compressing process However should problems develop with the cut in cut out settings please consult your MGF dealer NOTES a If the machine pumps continuously without cutting out then the compressor is too small for the application tool being used and damage may result Consult your MGF dealer b The motor is protected by a Thermal Overload which will t...

Страница 5: ...n case of a performance drop please contact a specialized technician to replace consumables and sealing parts Periodicity check every 12 months is based on an use estimate of 1h day 1h of ON cycle with a max working cycle of 50 eg 50 sec ON 50 sec OFF in case of more critical uses correspondingly reduce check periodicity FAULT FINDING PROBLEM PROBABLE CAUSE REMEDY Compressor does not start or stop...

Страница 6: ... filter blocked Bleed pipe from pressure switch to non return valve broken or disconnected Replace oil filler air filter plug Reconnect or replace bleed pipe SPECIFICATIONS MGF code Model description Air displacement Air delivery Motor Voltage frequency Air receiver Lt min CFM Lt min CFM HP Watt V Hz Lt S OF050 Beverage compressor 12 0 41 6 0 22 0 15 110 230 50 Not present MGF code Model descripti...

Страница 7: ...RICATION ET LA FOURNITURE DES PRODUITS DECLARAMOS QUE BAJO NUESTRA RESPONSIBILIDAD EXCLUSIVA POR LA FABRICACION Y PROVISION EL NOSTRO PRODUCTO BEVERAGE LINE A CUI LA PRESENTE DICHIARAZIONE SI RIFERISCE SONO CONFORMI ALLE SEGUENTI DIRETTIVE CEE TO WHICH THIS DECLARATION RELATES ARE IN CONFORMITY WITH FOLLOWING DIRECTIVES CEE AUX QUELS CETTE DECLARATION EST LIEE SONT CONFORMES AUX NORMES MAJEURES SU...

Страница 8: ...MGF S r l Via Pascoli 15 20081 Abbiategrasso MI ITALY Tel 39 02 9019253 680 Fax 39 02 9019273 e mail info mgfcompressors it www mgfcompressors com REV 01 2019 ...

Отзывы: