![MGF HELPADENT Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/mgf/helpadent/helpadent_use-and-maintenance-instruction-handbook_1783139012.webp)
HELPADENT UNIT COMPRESSOR WORKING DESCRIPTION
Firstly ensure the HELPADENT unit is on level ground. Do not allow it to run if it is standing on an
incline.
Check also that mains voltage corresponds with that shown on the data label on the side of the
compressors.
Ensure that on/off switch mounted on the pressure switch is turned to off position, then plug in the
unit and switch on.
Wait the compressor make an entire air receiver cycle.
Ensure that compressor outlet pressure is 6 BAR – 80 psi as displayed by outlet pressure gauge. If It
is necessary it is possible to adjust by setting the pressure regulator.
To do this lift the pressure regulator knob, and turn clockwise to increase pressure, anticlockwise to
decrease.
If during the HELPADENT unit use the compressor pumps continuously without cutting out
probably there is an excessive air use. Do not exceed the duty cycle for the machine.
COMPRESSOR MAINTENANCE
Check periodically the compressor in HELPADENT unit. Check the oil level by oil level window
and top up if necessary removing the oil filler plug and inject oil inside until the oil level is midway
on oil sight glass.
Drain any condense that may have accumulated in the air outlet filter regulator by pushing the valve
upwards.
When you have finished to use HELPADENT unit always open the drain valve to expel all air and
to allow any condense to drain off.
TECHNICAL FEATURES
Air receiver
4 Lt
Air inspired
50 Lt/min
Max. pressure working
8 BAR – 108 psi
Installed power
0,5 Hp – 0,37 W
Dimensions
W 460 x H 440 x D 320
Weight
29 Kg
12