MGF 932299 Скачать руководство пользователя страница 2

General Information

General Information

SERVICE

For any form of technical assistance you can contact us in one of the following ways:

telephone: +39 0521 818301

fax: +39 0521 818202

email: 

[email protected]

We will serve you as soon as possible.

The shipment of material under repair must be previously authorized by means of the RMA form (binding condition for the 
collection of any goods under repair).

WARRANTY TERM

The product warranty covers any manufacturing defect for a period of time equal to one (1) year from the date of 
manufacture for products purchased with invoice, 2 years for products purchased by private individuals.

The following clauses expressly exclude the product from guarantee:

Consumables such as fuses, disposable battery, ..., insofar as the malfunction is caused by normal wear of the parts

Damage caused by improper operation

Bad maintenance

Machine tampering or modification

The company excludes from its responsibility any indirect damage, damage caused to people and things by defects and 
machine downtime, incorrect use, lack of maintenance.

Introduction

Introduction

The FGAS Leak Detector art. 932299 is the most reliable negative corona halogen leak 
detector at present. We integrate all our experience and customers’ feedback into this 
product, in hope that it could provide our customer the best price, performance and 
reliability. 
The sensitive elements adopt the advanced and reliable corona refrigerant sensor which 
has great sensitivity and excellent repeatability; the test program is controlled by the 
artificial intelligent microcomputer, with reasonable work procedure, easy and convenient 
to operate, complete functions and multiple self-adaptive capabilities; dual-color LED 
indicator light, with visual and clear display; smart and portable design is convenient for 
your mobile operation. When there is excessive refrigerant in the leak gas, this unit will 
automatically audio alarmed to effectively test the refrigerant leak. 

Technical features  

Adopt advanced, low power consumed, eight-bit microprocessor controller 

Dual-color LED indicator light with progressive and real time display 

Sensitivity adjustable, seven level alarming indicated by LED display 

Modular sensor, convenient for maintenance 

Seven levels audible and visual alarm 

Auto reset testing when the detector is turned on 

Battery level indication 

2

MGF

MGF

 srl –– Via Chico Mendes, 8 – 43058 Sorbolo Mezzani (PR) Italy – Tel. +39 0521-818301 Fax: +39 0521-818202

e-mail: [email protected] – 

www.mgftools.com

 – 

www.nebulizzare.com

Содержание 932299

Страница 1: ... Via Chico Mendes 8 43058 Sorbolo Mezzani PR Italy Tel 39 0521 818301 Fax 39 0521 818202 e mail info mgftools com www mgftools com www nebulizzare com Art 932299 FGAS Leak Detector User Manual Rev 3 dated 26 08 2021 ...

Страница 2: ...ive corona halogen leak detector at present We integrate all our experience and customers feedback into this product in hope that it could provide our customer the best price performance and reliability The sensitive elements adopt the advanced and reliable corona refrigerant sensor which has great sensitivity and excellent repeatability the test program is controlled by the artificial intelligent...

Страница 3: ...quipment Detect SF 6 in high voltage circuit breakers Detect most gases that contain chlorine Fluorine and Bromine halogen gases Detect cleaning agents used in dry cleaning applications such as perchloroethylene Operating Environment Temperature 0 C 50 C Humidity 95 RH non condensing Power supply two 2 C Alkaline Batteries supplied Sensor tip life under continuous operation more than 50 hours in n...

Страница 4: ...ey Check the battery level The interface and keys of halogen leak detector please refer to Figure 2 Battery Installation WARNING To reduce the risk of igniting flammable gases in a closed atmosphere batteries must be replaced in an open area or closed space without flammable gas 1 See figure 3 Using a thumb to push open the battery door located at the bottom of the detector then to remove the door...

Страница 5: ...l not interrupt detection 5 If alarm occurs before the sensing tip touches with the leakage source press Reset key to reset the current to 0 until there is no alarm then you could detect again 6 Press Mute key to close the alarm sound press it again to activate alarm sound loop operation 7 Press the BATTERY TEST key to check the battery level Halogen leak detector detecting method See Figure 4 1 V...

Страница 6: ... Pinpointing the leak source needs to manually adjust the sensitivity and reset the detector by the technician You could follow recommendations below 1 In areas where the atmosphere is contaminated with halogen refrigerant press reset key to ignore the leak in the background Make sure not move the sensor tip away from the contaminated background while resetting the detector 2 In windy area the lea...

Страница 7: ...ty Conformity Declaration Conformity Declaration MGF MGF srl Via Chico Mendes 8 43058 Sorbolo Mezzani PR Italy declares under its own responsibility that the FGAS Leak Detector art 932299 is in conformity with the following standards or standardized documents Safety Standards EN 61326 1 2013 Electromagnetic Compatibility 2014 30 EU MGF MGF srl Ing Maioli Francesco 7 MGF MGF srl Via Chico Mendes 8 ...

Страница 8: ...at the minimum guaranteed sensitivity is respected This test is carried out by means of a sample leak calibrated according to the specifications of the EN14624 2012 standard Date Signature 8 MGF MGF srl Via Chico Mendes 8 43058 Sorbolo Mezzani PR Italy Tel 39 0521 818301 Fax 39 0521 818202 e mail info mgftools com www mgftools com www nebulizzare com ...