MGE UPS Systems EPS 7000 Скачать руководство пользователя страница 7

page c i

Installation Manual

Contents

section

description  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page

Important Safety Instructions  . . . . . . . . . . . . . . . . . .Inside Front Cover
Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iv 
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iv 
How To Use This Manual  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .v 

CAUTION: Record All Serial Numbers

 . . . . . . . . . . . . . . . . . . . . . . .vi

Table of Contents  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .c-i

Section 1

Introduction

section

description  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page

1.0

Scope  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1

1.1

Reference Manuals  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1

1.2

Section Descriptions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1

1.3

General Description  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2

1.4

Receiving for Single Modules and Shared Systems   . . . . . . . . . . . .1-3

1.4.1

Handling  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3

1.4.2

Storage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3

1.4.3

Prerequisites to Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3

1.4.4

Environmental Considerations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3

1.4.5

Mechanical Considerations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4

1.4.6

Electrical Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4

1.5

UPS Single Module and Shared System Specifications . . . . . . . . . .1-4

1.5.1

Electrical Ratings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5

1.5.2

Output  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6

1.5.3

Mechanical  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6

1.5.4

Environmental   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6

Section  2

Description, Single Module and Shared Systems

section

description  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page

2.0

Single-Module Description  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1

2.0.1

Single-Module Internal components  . . . . . . . . . . . . . . . . . . . . . . . . .2-2

2.0.2

Single Module Major Internal Components   . . . . . . . . . . . . . . . . . . .2-3

2.0.3

Single Module Options  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5

2.1

Shared System Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6

2.1.1

Shared System Major Internal Components  . . . . . . . . . . . . . . . . . . .2-9

2.1.2

Shared System Options  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-9

2.2

SSC Major Internal Components  . . . . . . . . . . . . . . . . . . . . . . . . . .2-10

2.2.1

Static Switch Cabinet Specifications  . . . . . . . . . . . . . . . . . . . . . . . .2-11
2.2.1.1   Electrical  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-11
2.2.1.2   Mechanical  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-11

C o n t e n t s

Содержание EPS 7000

Страница 1: ...EPS 7000 Single Module and Shared Systems Installation Manual w w w m g e u p s c o m...

Страница 2: ...ubject to change please ask for confirmation of the information given in this publication ATTENTION Comme les normes sp cifications et produits peuvent changer veuillez demander confirmation des infor...

Страница 3: ...stallation Manual For service call 1 800 523 0142 86 134003 00 X1 01 06 Copyright 2004 MGE UPS SYSTEMS Inc All rights reserved Printed in U S A MGE UPS SYSTEMS Inc 1660 Scenic Avenue Costa Mesa CA 926...

Страница 4: ...no one else Accessories supplied by MGE UPS SYSTEMS Inc but manufactured by others carry any warranty the manufacturers have made to MGE UPS SYSTEMS Inc and which can be passed on to Purchaser MGE UPS...

Страница 5: ...ote lines and icons to convey important information Note lines and icons come in four variations WARNING Indicates information provided to protect the User and service personnel against safety hazards...

Страница 6: ...___________________ ______________________________ __________________________ ______________________________ __________________________ ______________________________ __________________________ ______...

Страница 7: ...rations 1 3 1 4 5 Mechanical Considerations 1 4 1 4 6 Electrical Considerations 1 4 1 5 UPS Single Module and Shared System Specifications 1 4 1 5 1 Electrical Ratings 1 5 1 5 2 Output 1 6 1 5 3 Mecha...

Страница 8: ...Connections 3 5 3 3 4 Power Connections Inter Cabinet 3 5 3 4 AC Output Connections for Single Module and Shared Systems 3 5 3 4 1 Single Module 3 5 3 4 2 Shared Systems 3 5 3 4 3 Customer Control Con...

Страница 9: ...2 4 Typical Single Line Diagram 480 VAC Input Output Multi Module UPS with Battery Disconnect 2 7 2 5 Single Line Diagram typical EPS 7000 Shared Installation 2 7 2 6 EPS 7000 Major Internal Component...

Страница 10: ...This page left blank intentionally EPS 7000 Single and Shared Systems page c iv...

Страница 11: ...PS 7000 uninterruptible power system Single Module and Shared Systems receiving handling and storage procedures including a general description of system specifications Section 2 Descriptions Single M...

Страница 12: ...SSC battery and all auxiliary equipment is listed for safety by Underwriter s Laboratories Inc UL under UL Standard 1778 and under Canadian Standards Association CSA standard C22 107 Major components...

Страница 13: ...lashing water chemical agents etc The equipment should be covered with a tarpaulin or plastic wrapper to protect it against dust dirt paint or other foreign materials IMPORTANT Batteries should be sto...

Страница 14: ...t a structural engineer while planning your EPS 7000 UPS installation After installation the EPS 7000 module requires a minimum of 1 meter 36 inches front and top clearance for normal maintenance Side...

Страница 15: ...amps 481 amps 601 amps 289 amps 385 amps 481 amps Bypass voltage 480 VAC 3PH 480VAC 3PH 480VAC 3PH 600VAC 3PH 600VAC 3PH 600VAC 3PH 3or4W G 60hz 3or4W G 60hz 3or4W G 60hz 3or4W G 60hz 3or4W G 60hz 3or...

Страница 16: ...m Depth 39 in 991 mm Width See Table 2 1 Weight See Table 2 1 Finish MGE light gray 1 5 4 Environmental Recommended environment 20 to 25 C 68 to 77 F 50 relative humidity computer room or other temper...

Страница 17: ...2 1 EPS 7000 Single Module Ratings WEIGHT LBS KG UPS MBP XFMR TOTAL 300 400 500 kVA Single Module 480V 6 900 3 130 540 245 OPT 7 440 3 375 60hz 600V 6 900 3 130 540 245 3 600 1 640 11 040 5 015 A5 B5...

Страница 18: ...S MULTI SLOT OPTION BLOWERS 4X BLOWERS 4X BLOWERS 3X RAUZ2 PCA OPT RAUZ PCA IBEZ PCA OBEZ PCA INVERTERS 6X DC CAPS BAIZ1 PCA TREZ PCA SSSZ PCA ALBZ PCA EPOZ PCA ACOZ PCA ACUZ PCA ARUZ PCA OUTPUT XFMR...

Страница 19: ...a computer grade sinewave output voltage waveform with a total harmonic distortion of less than 2 under linear load conditions Static Switches An output and a bypass static switch is provided to trans...

Страница 20: ...Figure 2 3 Circuit Breaker locations in Maintenance Bypass Cabinet Description EPS 7000 Single and Shared Systems page 2 4...

Страница 21: ...Alarm Status Panel RASP For single module systems a remote alarm status panel RASP is available The RASP allows the following status indications to be viewed from a remote location UPS on line UPS on...

Страница 22: ...80 VAC Input Output Multi Module UPS with Battery Disconnect Table 2 2 EPS 7000 Shared Systems Ratings WEIGHT LBS KG UPS MBP XFMR TOTAL 300 400 500 kVA Shared system 480V 6 800 3 090 NA OPT 6 800 3 09...

Страница 23: ...V MODELS TRANSFORMER CABINET MAINTENANCE BYPASS AC INPUT BYPASS AC INPUT MAINS 2 Q4S CUSTOMER SUPPLIED STATIC SWITCH Q2S STATIC SWITCH CABINET FROM ADDITIONAL UPS MODULES TO ATTACHED LOAD MAINTENANCE...

Страница 24: ...PCA INVERTERS 6X DC CAPS APOZ PCA ACPZ PCA ARUZ PCA OUTPUT XFMR BEHIND PANEL ALEZ PCA AROZ_7000 PCA CROZ_7000 PCA CRIZ_7000 PCA SRIZ PCA GTCZ_7000 PCA GT2Z_7000 PCA OPT INPUT FILTER 3X OUTPUT FILTER...

Страница 25: ...lable for the EPS 7000 series 800 UPS Some configurations do not support some options Most options must be specified at the time of equipment order some options can be installed in the field Contact y...

Страница 26: ...ally the RSAP contains an audible alarm and two pushbuttons Alarm test reset pushbutton Audio reset pushbutton 2 2 SSC Major Internal Components The static switch cabinet SSC provides an electrical pa...

Страница 27: ...C Wires 3 or 4 wires plus ground Current 4 000 Amperes max AC output ratings Voltage 480 VAC 380 400 415 VAC Frequency 60 Hz 50 Hz Phases 3 Wires 4 wires plus ground Current 4 000 Amperes max Power fa...

Страница 28: ...UZ PCA ACPZ PCA OBEZ CAPACITORS C11 C12 C13 FAR SIDE OF PANEL PCA IBEZ CARD CAGE TRANSFORMER T12 CIRCUIT BREAKER Q2S FUSES F11 F12 F13 FAR SIDE OF PANEL STATIC SWITCH STATIC SWITCH PCA SSSZ PCA GTCZ P...

Страница 29: ...ttery cabinet s if any and auxiliary cabinet s if any to their final location as described in the Mechanical considerations section For cabinets installed adjacent to each other alignment is critical...

Страница 30: ...tective devices and distribution circuits should be OFF open The lugs used to secure the cables should be torqued as per the recommendation listed in Cable preparation for field wiring MGE document 9...

Страница 31: ...s 50 000 amps Nominal 3 8 inch 9 5m Nylon rope or rope having a minimum tensile strength of 2000 Lbs 8896 N at 6 inches 152m and 12 inches 305mm from the terminals with five wraps and every additional...

Страница 32: ...2 Connections The bypass AC input source is connected to the SSC The connections to be made are the three phases optional neutral and ground connections Termination of these connections within the SS...

Страница 33: ...cable sizing data is provided on the installation drawings 3 4 2 Shared Systems The connections to be made are the three phases ground and optional neutral cables between the SSC output and the load...

Страница 34: ...ting the EPS 7000 read thoroughly the EPS 7000 Users Manual MGE part number 86 134005 00 00 86 134004 00 Be certain that you fully understand the operation of the indicators controls and operational s...

Страница 35: ...l for procedures as applicable to your installation Emergency power off EPO test Remote emergency power off REPO test if applicable Inverter start and stop Battery transfer test Maintenance bypass pro...

Страница 36: ...This page left blank intentionally EPS 7000 Single and Shared Systems page 3 8 Installation...

Страница 37: ...SERVICING BATTERIES A Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries B Wh...

Страница 38: ...t the main operating sequences as applicable to your equipment configuration and installation 4 4 Replacement Parts There are no user replaceable parts inside the EPS 7000 Three levels of replacement...

Страница 39: ...noise The noise level of the environment Attached load The load attached to the UPS output such as a computer system or manufacturing system Audible alarm A buzzer located behind the front panel on th...

Страница 40: ...lectrical or electronic equipment FET Field effect transistor Freq Frequency Frequency slew rate The change in frequency per unit of time Given in term of Hz per second Hz sec GND Ground safety Hz Her...

Страница 41: ...Roman numerical system indicating 1000 Module Refers to individual power inverter module N Neutral NC Normally close NO Normally open NEC National Electrical Code NFPA National Fire Protection Associa...

Страница 42: ...e while it is in transit SPDT Single Pole Double Throw SSC Static switch cabinet in shared systems Static Transfer An solid state switching mechanism electronically controlled to pass AC power directl...

Страница 43: ...Glossary page g 5 Installation Manual VA Volt amps unit for apparent power measurement equal V x I VAC or Vac Voltage of AC type VDC or Vdc Voltage of DC type ve Battery voltage Via By way of...

Страница 44: ...This page left blank intentionally EPS 7000 Single and Shared Systems page g 6...

Страница 45: ..._______________________________________________________________________________ STREET ADDRESS _________________________________________________________________________ CITY __________________________...

Страница 46: ......

Страница 47: ......

Страница 48: ...1660 Scenic Avenue Costa Mesa California 92626 714 557 1636 w w w m g e u p s c o m...

Отзывы: