1.2 Rear Panels

Pulsar MX 5000 RT

Pulsar MX EXB RT 

Transformer 5000

(1)

One group of 4 L6-30R outlets for connection of equipment

(2)

Output terminal block

(3)

Normal AC source input cable with L6-30P

(4)

Connector for additional battery module

(5)

Slot for optional communication card

(6)

USB communication port

(7)

RS232 communication port

(8)

Communication port by relay

(9)

Connector for Remote Power Off control

(10)

Connector for automatic detection of battery module(s)

(11)

Connectors for automatic detection of battery module(s)

(12)

Connectors for battery modules (to the UPS or to the other battery modules)

(13)

DC Battery circuit breaker

(14)

Resetable 20Amp circuit breakers for NEMA 5-15/20 receptacle

(15)

6 NEMA 15/20 receptacle

(16)

Resetable 20Amp circuit breakers to protect each L5-20R receptacle

(17)

Input cable with L6-30P plug

(18)

Input resetable CB

(19)

2 NEMA L5-20R receptacle

(63)

Input voltage selecting (240V/208)

(64)

Transformer protection CB

BATT. NO.

200-250V~,24A

RPO

RS-232

CAUTION:

DO NOT

 DISCONNECT

BA
TTER

Y

 CABLE

UNDER LOAD

BA
TTER

Y

 

CONNECT

O

R

             

180VDdc

1

5

8
9

10

4

6

7

2

3

13

11

12

12

LOAD 4 / 120V~,16A

LOAD 1

120V~,16A

LOAD 2

120V~,16A

SET
 THIS

SWITCH WHEN

UNPOWERED

BY

 ALL
 SOURCES

INPUT

 VOL

TAGE

SELECTION

240~

208~

INPUT

BREAKER

TRANSFORMER

PROTECTION

LOAD 3 / 120V~,16A

LOAD 3

BREAKER

LOAD 1

BREAKER

LOAD 2

BREAKER

LOAD 4

BREAKER

19

17

63

18

64

14

16

15

Pulsar MX 

Presentation

1 — 2

86-87050-00 A01 

Содержание 5000 RT

Страница 1: ...Pulsar MX 5000 RT UPS EXB RT Extended Battery Transformer 5000 Installation and User Manual w w w m g e u p s c o m...

Страница 2: ......

Страница 3: ...r Manual 86 87050 00 Revision A00 ECN 004747 04 2006 Revision A01 ECN 004773 05 2006 Copyright 2006 MGE UPS SYSTEMS INC All rights reserved Printed in U S A MGE UPS SYSTEMS INC 1660 Scenic Avenue Cost...

Страница 4: ...Pulsar MX 86 87050 00 A01...

Страница 5: ...2 8 Connection to Output Receptacles 2 8 2 9 Connection of Extended Battery Module UPS and Transformer 2 8 Operation 3 1 Initial Start Up 3 1 3 2 Final Start Up Sequence 3 1 3 3 Operating Modes 3 2 3...

Страница 6: ...odule 7 2 Appendices Technical Specifications 8 1 MGE Warranty Proprietary Rights for Single Phase Products MGE Standard Single Phase Warranty Proprietary Rights Statement Customer Care Center Single...

Страница 7: ...ts The cardboard we use comprises over 50 of recycled cardboard Sacks and bags are made of polyethylene Packing materials are recyclable and bear the appropriate identification symbol Follow all local...

Страница 8: ...current may be very high Precautions must be taken for all handling remove watches rings bracelets and any other metal objects use tools with insulated handles Do not lay tools or metal parts on top...

Страница 9: ...mbol Usage Important instructions that must always be followed Information advice help Visual indication Action Audible signal LED off LED on Installation and User Manual 3 86 87050 00 A01 Introductio...

Страница 10: ...This page left blank intentionally Pulsar MX 4 86 87050 00 A01...

Страница 11: ...650 Transformer 5000 17 5 x 3 5 x 25 6 444 5 x 88 9 x 650 Weights in lbs kg Pulsar MX 5000 RT 125 57 Pulsar MX EXB RT 154 70 Transformer 5000 84 38 Dimensions H x W x D in inches mm Pulsar MX 5000 RT...

Страница 12: ...es 13 DC Battery circuit breaker 14 Resetable 20Amp circuit breakers for NEMA 5 15 20 receptacle 15 6 NEMA 15 20 receptacle 16 Resetable 20Amp circuit breakers to protect each L5 20R receptacle 17 Inp...

Страница 13: ...mm to 1005 mm length 27 36 to 39 96 35 36 37 20 Load protected LED 21 Downgraded operation LED 22 Load not protected LED 23 Alphanumeric display 24 Escape cancel button 25 Function buttons scroll down...

Страница 14: ...battery cable will be used instead of the standard battery cable when battery modules are distant from each other located in two different enclosures for instance The Battery Integration System is int...

Страница 15: ...on A dangerous voltage is present inside the power module and the battery module Any operations to be carried out on these modules must be done so by qualified personnel i 48 Network Management card o...

Страница 16: ...ce between the tower stands should be 17 7 inches 6 inches 17 7 inches 1 Remove the two mounting screws 59 to free the battery disconnect switch 60 2 Push the battery disconnect switch so that you can...

Страница 17: ...s rack integration we strongly recommend to remove the battery tray as shown below 2 3 1 Installation and User Manual Installation 2 3 86 87050 00 A01 To adjust the display position 1 Pull display pan...

Страница 18: ...o the rails The rails and the necessary mounting hardware are supplied by MGE UPS SYSTEMS Note for step 1 It is possible to adjust the position of both front mounting brackets Rear bracket system incl...

Страница 19: ...on port by relays 8 When the status is active the contact between the common Pin 5 and the relevant information pin is closed Output relays specifications Voltage 48 V DC max Current 2 A max Power 62...

Страница 20: ...on Note The internal batteries will remain connected to the power sub module after RPO activation The cable is not included Installation of optional communication card 66102 2 6 Required Protective De...

Страница 21: ...y others BATT NO 20 0 2 50 V 24 A RPO RS 232 CAU TION DO NO T DIS CO NN EC T BAT TER Y CA BLE UN DE R LOA D BAT TER Y CO NN EC TO R 180 VDd c 2 3 2 3 Output Terminal L2 N GND L1 1 Remove the top of th...

Страница 22: ...power module and to the connector 11 of the battery module 4 Switch on the battery circuit breaker s 13 TRANSFORMER INPUT CABLE BATTERY MODULE BATTERY MODULE UPS MODULE Pulsar MX TRANSFORMER MODULE 1...

Страница 23: ...and after UPS internal test sequence the LED 20 is ON LEDs 30 32 34 are green The equipment is protected by the UPS If LED 21 or 22 is ON an alarm has occurred see the troubleshooting section 20 30 32...

Страница 24: ...n advantage of the Eco mode see glossary is that it reduces the consumption of electrical power Under normal condition Normal AC source available LED 20 is ON LEDs 33 34 are green The equipment is sup...

Страница 25: ...displays End of backup time Battery low LEDs 20 21 are ON LEDs 31 32 34 are green The audible alarm beeps every 3 seconds The remaining battery power is low Shut down all applications on the connecte...

Страница 26: ...oll button 25 to select yes 4 Press confirm button 27 The UPS is now fully shut down 25 28 27 NO YES 1 Press and hold the 0 off button 28 for 3 seconds The buzzer beeps once The load is no longer prot...

Страница 27: ...3 Press the scroll button 25 a number of times to point to the UPS set up or Maintenance menu Press the Enter button 27 to get access Local settings Output settings ON OFF settings Battery settings Mo...

Страница 28: ...g Options Comments Output Voltage 208V 200V 230V 220V 240V 250V Freq Converter Disabled Enabled Output Frequency 60 Hz 50 Hz User selectable under frequency converter mode Eco Mode Disabled Enabled Se...

Страница 29: ...ual Battery Test No Yes Led Buzzer Test Led Buzzer Test No Yes Life Cycle Monitoring LCM Enable Disable Life cycling monitoring alarms Statistics Auto Statistics Statistics You need to register at www...

Страница 30: ...This page left blank intentionally Pulsar MX 4 4 86 87050 00 A01...

Страница 31: ...is not inserted Check power sub module connections see section 7 1 NO BATTERY MODULE The battery sub module is incorrectly connected Check battery connections see section 7 2 INV THERM OVERLOAD The UP...

Страница 32: ...523 0142 Follow the power sub module replacement procedure see sections 7 1 and 7 2 BATT MODULE FAULT Battery fault detected during the bat tery test Use Enter button 27 to display details Call the a...

Страница 33: ...registration at www mgeups com lcm FREE STATISTIC FEATURE FOR PRODUCT WEB REGISTRATION CONTACT MGE AT www mgeups com lcm Get free offer after registration at www mgeups com lcm These statistics will...

Страница 34: ...events that can happen on the UPS if you disable all LCM messages LCM warning details Signification END OF WARRANTY SOON CONTACT MGE AT www mgeups com lcm Get your product warranty extension by conta...

Страница 35: ...ion must be carried out by qualified electrical personnel only Disconnecting the battery sub module 87101 1 Remove the 6 mounting screws to free the main front panel bezel 2 Place the front panel abov...

Страница 36: ...Pulsar MX 86 87050 00 A01...

Страница 37: ...tput power 5000 VA 1 4500 W 2 Electrical supply network Rated input voltage Input voltage range Frequency Power factor Leakage current Single phase 208 V 120 156 V to 280 V 3 50 60 Hz autoselect 0 99...

Страница 38: ...r maintenance of the subject product In no event will MGE be liable for any labor subcontracted or performed by Purchaser for preparation of the warranted item for return to MGE s factory or for prepa...

Страница 39: ...73 Hours 24 7 Customer FAQ or International calls 1 714 557 1636 Commitment MGE UPS SYSTEMS INC is committed to providing easy to access factory trained experts that will provide responses to any ques...

Страница 40: ...Pulsar MX 86 87050 00 A01...

Страница 41: ...ch in turn conversion mode supplies the connected equipment after electronic double conversion Frequency converter Operating mode used to convert the AC power frequency between the UPS input and outpu...

Страница 42: ...Notes Pulsar MX 86 87050 00 A01...

Страница 43: ......

Страница 44: ...Fax 714 557 9788 email info mgeups com www mgeups com Canada MGE UPS SYSTEMS 9 2789 Thamesgate Drive Mississauga ON L4T 4E8 Tel 905 672 0990 877 672 0990 Fax 905 672 7667 email info mgeups com www mg...

Отзывы: