MG Energy Systems MGEMD010001 Скачать руководство пользователя страница 1

 

 

MG Energy Systems B.V. | Foeke Sjoerdswei 3 | 8914 BH Leeuwarden | The Netherlands  

+31 (0)58 750 89 47 | [email protected] | www.mgenergysystems.eu

 

Innovation

 in energy storage 

 

 

MG Energy Monitor 

MGEMD010001 

Manual EN 

 

 

 

 

 

 

Version: 

1.0 

Date:   

26-03-2020 

 

 

Содержание MGEMD010001

Страница 1: ...V Foeke Sjoerdswei 3 8914 BH Leeuwarden The Netherlands 31 0 58 750 89 47 info mgenergysystems eu www mgenergysystems eu Innovation in energy storage MG Energy Monitor MGEMD010001 Manual EN Version 1...

Страница 2: ...ITY OR FITNESS FOR A PARTICULAR PURPOSE REGARDING THESE MG ENERGY SYSTEMS B V PRODUCTS AND MAKES SUCH MG ENERGY SYSTEMS B V PRODUCTS AVAILABLE SOLELY ON AN AS IS BASIS IN NO EVENT SHALL MG ENERGY SYST...

Страница 3: ...8 2 2 3 Non compliance risks 8 2 2 4 Unacceptable modes of operation 8 3 TRANSPORT STORAGE AND UNPACKING 9 3 1 Transport 9 3 2 Storage 9 3 3 Unpacking 9 3 3 1 Scope of delivery 9 4 GENERAL DESCRIPTIO...

Страница 4: ...ns 18 7 4 Using the touchscreen 19 8 INSTALLATION 20 8 1 Installation procedures 20 8 2 Mounting procedure 20 8 3 Electrical connection procedure 22 8 3 1 CAN bus connection procedure 22 8 3 2 Externa...

Страница 5: ...e continuing read the manual in this chapter carefully and be sure the information instructions and procedures are fully understood If there are questions after reading then please consult MG Energy S...

Страница 6: ...it within the operation specifications EMS Energy Management System The EMS controls all power sources and consumers in a system CAN bus Controller Area Network bus CAN bus is a standard serial data...

Страница 7: ...A potential situation which if not avoided could result in an undesirable result or state A practice not related to personal injury 2 2 User health and safety 2 2 1 General precautions This product is...

Страница 8: ...hey have higher priority over the manufacturer s specification in this manual in case of regulatory conflicts Instruction and training can be carried out by MG Energy Systems B V by order of the user...

Страница 9: ...is not transported in its original packaging or if the original packaging is opened before the destination is reached 3 2 Storage The storage instructions provided by the manufacturer must be followe...

Страница 10: ...Monitor Consult MG Energy Systems B V for compatibility between device types 4 2 Functional description The main purpose of the Energy Monitor is to show battery system information and parameters Sec...

Страница 11: ...identifications label shown in figure 1 contains written information about the product The explanation of the symbols used on the identification label is stated in Table 3 Table 3 Identification labl...

Страница 12: ...ds 31 0 58 750 89 47 info mgenergysystems eu www mgenergysystems eu Innovation in energy storage 6 CONNECTIONS This chapter shows an overview of the connections and parts of the MG Energy Monitor 6 1...

Страница 13: ...s The MG Energy Monitor communicates with and is powered by the connected system via CAN bus This is a dedicated CAN bus where only MG battery modules of the same type or other MG devices may be conne...

Страница 14: ...don t have any twisted pairs and are therefore not suitable for this application 6 2 2 External power connector The external power connector is used to provide power to the Energy Monitor This is opti...

Страница 15: ...r to the relevant page Here a status message will be shown indicating what is causing the issue In each of the following subsections one of the main pages will be described to get a full overview of a...

Страница 16: ...iew of all the devices in the connected system By using the arrow buttons or swiping up or down it is possible to scroll through the devices Clicking on any of the buttons will show specific informati...

Страница 17: ...ters of the Energy Monitor including the brightness or what wireless network it should connect to Please refer to the User Guide for more in depth information about all the possible settings 7 1 6 3 S...

Страница 18: ...ppear in the top right of each of the main pages These give the user a quick indication about the status of the Energy Monitor Table 6 Status icons Icon Function Wi Fi connected Establishing Wi Fi con...

Страница 19: ...user interface of the Energy Monitor and are used for most of the user interactions To get a detailed description of all possible interactions please refer to the User Guide Table 7 Default buttons I...

Страница 20: ...ration settings of the product as described in the manual Ensure that the equipment is used under the correct operating conditions 8 1 Installation procedures Below a list of the basic installation pr...

Страница 21: ...ems eu Innovation in energy storage 2 Remove the mounting screws and mounting strips from the back of the device Figure 7 Mounting details 3 Place the device in the cut out 4 Place the mounting strips...

Страница 22: ...Figure 8 and Figure 9 for what connectors to use on the different MG Master devices This can either be RJ45 or M12 connectors See chapter 11 for cables and adaptor cables information Figure 8 MG Mast...

Страница 23: ...rden The Netherlands 31 0 58 750 89 47 info mgenergysystems eu www mgenergysystems eu Innovation in energy storage Connection of the CAN bus cable connectors or termination resistor is done in the fol...

Страница 24: ...rgysystems eu Innovation in energy storage 2 Bring the connections face of the cable connector up the device connector in such a way that the position of the key matches to that of the opposing connec...

Страница 25: ...osite order 8 3 2 External power supply connection To connect external power to the Monitor refer to the following steps 1 Match alignment of the pins on both the connector and the cable 2 Lock the co...

Страница 26: ...e section 6 2 If this does not work try updating the Energy Monitor see section 9 2 as well as the connected MG Master device see device specific manual 9 1 1 Cleaning Cleaning of the device is best d...

Страница 27: ...r running the MG Diagnostics Tool software is meant with it For a full instruction of the MG Diagnostic Tool refer to the manual of the software Updating procedure 1 Connect a USB to CAN transceiver t...

Страница 28: ...ensions 103 x 70 x 39 mm Weight 150 g LCD screen Type TFT Size 3 5 diagonal Resolution 480 x 320 Colours 262K Brightness 500 cd m2 Dimming Yes Wi Fi connectivity Protocol 802 11 b g n RF certification...

Страница 29: ...V Foeke Sjoerdswei 3 8914 BH Leeuwarden The Netherlands 31 0 58 750 89 47 info mgenergysystems eu www mgenergysystems eu Innovation in energy storage 10 2 Dimensions Unless otherwise mentioned all di...

Страница 30: ...M12 CANOpen Male 90 deg rot 90 deg to RJ45 1m MGM12000020 M12 CANOpen Terminator Female MGM12000010 M12 CANOpen Terminator Male MGM12005002 M12 CANOpen cable 0 to 0 deg 0 5m MGM12100002 M12 CANOpen c...

Страница 31: ...fo mgenergysystems eu www mgenergysystems eu Innovation in energy storage 12 CONTACT DETAILS For specific questions please feel free to contact us MG Energy Systems B V Foeke Sjoerdswei 3 NL 8914 BH L...

Отзывы: